Veritas NetBackup™ 5330 Appliance Hardware Installation Guide
- Hardware overview
- Pre-installation requirements
- Hardware installation procedures
- Hardware installation procedures for a NetBackup 5330 high availability configuration
- Appendix A. Adding the disk space of a new Expansion Storage Shelf
NetBackup 5330 compute node PCIe card configurations
The rear panel of the compute node contains six PCIe slots that are numbered 1 to 6. Slots 1, 2, and 3 are located in PCIe Riser Assembly 2. Slots 4, 5, and 6 are located in PCIe Riser Assembly 1.
All PCIe slots are factory-populated. Each slot contains either a Fibre Channel (FC) host bus adapter (HBA) card or an Ethernet network interface card (NIC). Slots 1 and 4 are reserved exclusively for attachment to the Primary Storage Shelf.
The PCIe card configurations for the NetBackup 5330 compute node are shown in the table.
Table: Available PCIe slot configurations for the NetBackup 5330 compute node
I/O configuration options | Slot 1 | Slot 2 | Slot 3 | Slot 4 | Slot 5 | Slot 6 |
---|---|---|---|---|---|---|
A | 8 Gb FC HBA | 10 GbE NIC | 10 GbE NIC | 8 Gb FC HBA | 10 GbE NIC | 10 GbE NIC |
B | 8 Gb FC HBA | 10 GbE NIC | 10 GbE NIC | 8 Gb FC HBA | 10 GbE NIC | 8 Gb FC HBA |
C | 8 Gb FC HBA | 10 GbE NIC | 10 GbE NIC | 8 Gb FC HBA | 8 Gb FC HBA | 8 Gb FC HBA |
D | 8 Gb FC HBA | 8 Gb FC HBA | 10 GbE NIC | 8 Gb FC HBA | 8 Gb FC HBA | 8 Gb FC HBA |
E | 8 Gb FC HBA | 8 Gb FC HBA | 8 Gb FC HBA | 8 Gb FC HBA | 8 Gb FC HBA | 8 Gb FC HBA |