- Hardware overview
- Pre-installation requirements
- Hardware installation procedures
- Hardware installation procedures for a NetBackup 5330 high availability configuration
- Appendix A. Adding the disk space of a new Expansion Storage Shelf
Installing the SFPs into the Fibre Channel (FC) ports
Four small form-factor pluggable (SFP) transceivers are provided. You must insert them into the four Fibre Channel (FC) ports in slots 1 and 4 in the compute node rear panel.
To install the SFPs
- Locate the SFPs.
- Identify the FC ports in slots 1 and 4.
- Remove the black rubber cap on each SFP that you want to install.
- Slide the SFP completely into the port until it clicks into place.
Be sure that the metal handle on the end of the SFP is on the top. You do not need to lift up the handle.
- Verify that the SFP is seated properly.
The SFPs should be parallel to each other. They should not be twisted or incompletely inserted.