Please enter search query.
Search <book_title>...
Veritas NetBackup™ Appliance コマンドリファレンスガイド
Last Published:
2018-03-08
Product(s):
Appliances (3.1.1 (5340), 3.1.1 (5330), 3.1.1 (5240), 3.1.1 (5230), 3.1.1 (5220))
- 概要
- 付録 A. Main > Appliance コマンド
- 付録 B. Main > Manage > FibreChannel コマンド
- 付録 C. Main > Manage > HighAvailability コマンド
- 付録 D. Main > Manage > Libraries コマンド
- 付録 E. Main > Manage > Libraries > Advanced > ACS コマンド
- Manage > Libraries > Advanced > ACS > ACS_CSI_HOSTPORT
- Manage > Libraries > Advanced > ACS > ACS_SEL_SOCKET
- Manage > Libraries > Advanced > ACS > ACS_SSI_HOSTNAME
- Manage > Libraries > Advanced > ACS > ACS_SSI_INET_PORT
- Manage > Libraries > Advanced > ACS > ACS_SSI_SOCKET
- Manage > Libraries > Advanced > ACS > ACS_TCP_RPCSERVICE
- Manage > Libraries > Advanced > ACS > ACS_UDP_RPCSERVICE
- Manage > Libraries > Advanced > ACS > API_BARCODE_RULES
- Manage > Libraries > Advanced > ACS > TestACS
- Manage > Libraries > Advanced > ACS > ViewVMconf
- 付録 F. Main > Manage > License コマンド
- 付録 G. Main > Manage > MountPoints コマンド
- 付録 H. Main > Manage > NetBackup CLI コマンド
- 付録 I. Main > Manage > OpenStorage コマンド
- 付録 J. Main > Manage > Software コマンド
- Manage > Software > Cancel
- Manage > Software > Delete
- Manage > Software > Download
- Manage > Software > DownloadProgress
- Manage > Software > Firmware
- Manage > Software > Install
- Manage > Software > List
- Manage > Software > LiveUpdateClients
- Manage > Software > Readme
- Manage > Software > Rollback
- Manage > Software > Share
- Manage > Software > UpgradeStatus
- 付録 K. Main > Manage > Storage コマンド
- 付録 L. Main > Manage > Tapes コマンド
- 付録 M. Main > Manage > Certificates コマンド
- 付録 N. Main > Monitor コマンド
- 付録 O. Main > Network コマンド
- Network > Configure
- Network > Date
- Network > DNS
- Network > Gateway
- Network > Hostname
- Network > Hosts
- Network > IPv4
- Network > IPv6
- Network > LinkAggregation
- Network > NetStat
- Network > NTPServer
- Network > Ping
- Network > SetProperty
- Network > Show
- Network > TimeZone
- Network > TraceRoute
- Network > Unconfigure
- Network > VLAN
- Network > WANOptimization
- 付録 P. Main > Network > Security (IPsec) コマンド
- 付録 Q. Main > Reports コマンド
- 付録 R. Main > Settings コマンド
- Settings > Cloud
- Settings > Deduplication
- Settings > FibreTransport
- Settings > iSCSI > Initiator
- Settings > iSCSI > Interface
- Settings > iSCSI > Target
- Settings > LogForwarding
- Settings > LifeCycle
- Settings > LiveUpdateServer
- Settings > NetBackup
- [設定 (Settings)]>[パスワード (Password)]
- Settings > Share
- Settings > SNMP polling
- Settings > Sysctl
- Settings > SystemLocale
- 付録 S. Main > Settings > Alerts コマンド
- 付録 T. Main > Settings > Notifications view コマンド
- 付録 U. Main > Settings > Security コマンド
- 付録 V. Main > Support コマンド
- Support > Checkpoint
- Support > Cleanup > RemoveShelfEntries
- Support > Cleanup > ResetDIMMErrors
- Support > Collect
- Support > DataCollect
- Support > Disk
- Support > Errors
- Support > FactoryReset
- Support > FibreTransport
- Support > InfraServices
- Support > iostat
- Support > IPMI
- Support > KillRemoteCall
- Support > Logs
- Support > Maintenance
- Support > Messages
- Support > NBDNA
- Support > nbperfchk
- Support > NBSU
- Support > Processes
- Support > RAID
- Support > Reboot
- Support > RecoverStorage
- Support > Service
- Support > ServiceAllowed
- Support > Show
- Support > Shutdown
- Support > Storage ClearReservations
- Support > Storage Reset
- Support > Storage SanityCheck
- Support > Test
名前
Main > Support > Show — ハードウェア診断のための参照テーブルを表示します。
概要
Show HW-DiagnosisHelp
説明
このコマンドはハードウェア診断のための参照テーブルを表示するのに使います。参照テーブルを使って、ハードウェアのさまざまなエラー状態 (重要な警告または致命的エラーなど) の潜在的な原因を識別できます。
オプション
- Show HW-DiagnosisHelp
このコマンドはハードウェア診断のための参照テーブルを表示するために使います。
例
次は、Main > Support > Show HW-DiagnosisHelp コマンドを実行すると表示される情報の例です。
Reference Chart
+-----------------------------------------------------------------------------+
|ID| Device | State | Diagnosis |
|--+-----------+-------+------------------------------------------------------|
| | | | Check if both the Power Supply Units are cabled |
| |Power | | and is receiving power |
|1 |Supply |Warning| |
| | | | * If PS is cabled and receiving power, call |
| | | | Veritas support to replace the Power Supply Unit |
|--+-----------+-------+------------------------------------------------------|
| | | | Check the status column. |
| | | | |
| | | | * If the status is "Disabled", run the test again.|
|2 |CPU |Failed | (ipmitool may sometimes report incorrect CPU |
| | | | status) |
| | | | |
| | | | * If the failure persists, call Veritas support to|
| | | | replace the CPU |
|--+-----------+-------+------------------------------------------------------|
| | | | Check the status column |
| | | | |
| | | | * "Device Absent" indicates that the fan is either|
| | | | not inserted correctly or the power supply cable |
|3 |Fan |Failed | for the fan is loose. |
| | | | |
| | | | * If the fan is inserted correctly or the power |
| | | | supply cable is inserted correctly on the |
| | | | motherboard, call Veritas support to replace the |
| | | | fan. |
|--+-----------+-------+------------------------------------------------------|
| | | | Check the Speed column. |
| | | | |
| | | | * Speed will be above the high water mark levels. |
| | | | Check if any other fan is in failed state. If yes,|
| | | | call Veritas support to replace the failed fan. |
|4 |Fan |Warning| Once replaced, the speed will stay within water |
| | | | mark level. |
| | | | |
| | | | * If none of the other fans have failed, check the|
| | | | temperature table. If the temperature of appliance|
| | | | rises, then fan speed increases unless proper |
| | | | cooling is provided to the machine. |
|--+-----------+-------+------------------------------------------------------|
| | | | Check the "Slot number" column |
|5 |Disk |Failed | |
| | | | * Call Veritas support to replace the drive in |
| | | | that slot |
|--+-----------+-------+------------------------------------------------------|
| | | | Check the "Status" column |
| | | | |
| | | | * Drive in that slot was supposed to be in |
| | | | "Hotspare" state. It might have changed the state |
|6 |Disk |Warning| due to a drive failure in another slot. |
| | | | |
| | | | * If none of the other drives are in failed state,|
| | | | copyback needs to be initiated so that the drive |
| | | | in this particular slot becomes a "hotspare" |
|--+-----------+-------+------------------------------------------------------|
|7 |Fiber |Failed | * Call Veritas support to replace the FC card |
| |Channel | | |
|--+-----------+-------+------------------------------------------------------|
| | | | * Make sure enough cooling is provided so that the|
|8 |Temperature|Warning| temperature does not cross the high threshold |
| | | | limit |
|--+-----------+-------+------------------------------------------------------|
| | | | Check the "status" column |
|9 |RAID |Failed | |
| | | | * Multiple drive failure can result in RAID volume|
| | | | going offline |
|--+-----------+-------+------------------------------------------------------|
| | | | Check the "Write Policy" column |
| | | | |
| | | | * If it is in "WriteThrough" mode, check the "RAID|
| | | | adapter" table. If either the "BBU learn cycle |
| | | | active" field for that RAID adapter is "yes" OR if|
| | | | the "BBU charge" field is less than 60%, the write|
| | | | policy will temporarily remain in WriteThrough |
| | | | mode. |
| | | | |
|10|RAID |Warning| * If "BBU learn cycle active" is not "yes" AND |
| | | | "BBU charge" is more than 60%, change the write |
| | | | policy for RAID-6 to "WriteBack with BBU" using |
| | | | MegaCli |
| | | | |
| | | | * Status can be "Degraded" or "Partially |
| | | | degraded". One or more drives might have failed. |
| | | | Call Veritas support to replace the failed drive |
| | | | (s) and wait for the rebuild and copyback |
| | | | operation to complete. |
|--+-----------+-------+------------------------------------------------------|
| | | | Check "Adapter status" and "BBU status" column |
| | | | |
| | | | * Either adapter NVRAM, Memory, or Flash of the |
| | | | adapter is absent or bad. Call Veritas support to |
|11|Adapter |Failed | replace the RAID card |
| | | | |
| | | | * Either BBU,BBU voltage or BBU temperature is not|
| | | | OK, call Veritas support to replace the BBU on |
| | | | that adapter. |
|--+-----------+-------+------------------------------------------------------|
| | | | * This is a temporary state when either the BBU |
|12|Adapter |Warning| learn cycle is active or the BBU charge is less |
| | | | than 60% |
|--+-----------+-------+------------------------------------------------------|
| | | | * Warning indicates that either the PCI card in |
|13|PCI |Warning| not inserted in the compatible slot or an |
| | | | unsupported card is inserted. |
+-----------------------------------------------------------------------------+