Veritas NetBackup™ Administrator's Guide, Volume II
- NetBackup licensing models and the nbdeployutil utility
- About NetBackup licensing models
- Tools for creating and viewing licensing reports
- Setting the licensing type for scheduled reports
- How capacity licensing works
- How NEVC licensing works
- Scheduling reports for capacity licensing
- Scheduling reports for traditional licensing
- Scheduling reports for NetBackup Enterprise Virtual Client (NEVC) licensing
- Other configuration for incremental reporting
- Troubleshooting failures for nbdeployutil and incremental reporting
- Manually generating licensing reports
- Creating and viewing the licensing report
- Reviewing a capacity licensing report
- Summary tab
- Client aliases and multiple IP addresses
- Itemization tab
- Clients backed up with multiple streams
- NetBackup CloudCatalyst (NetBackup 8.1 and later clients)
- Data backed up by multiple policies
- BigData plug-ins for NetBackup
- NetBackup for Exchange agent
- NetBackup for NDMP agent
- NetBackup for Oracle server agent
- NetBackup for SQL Server agent
- NetBackup for VMware agent
- NetBackup for Hyper-V agent
- NetBackup for RHV agent
- NetBackup for Nutanix-AHV agent
- NAS-Data-Protection policy
- Cloud policy
- Windows file system backups
- UNIX file system backups
- Reconciling the capacity licensing report results
- Reviewing a traditional licensing report
- Reviewing an NEVC licensing report
- Using the NetBackup Storage API to get the total backup size information
- Additional configuration
- About multiple NetBackup master servers
- About multiple media servers with one master server
- About direct I/O for backups on Windows
- About dynamic host name and IP addressing
- About busy file processing on UNIX clients
- About specifying the locale of the NetBackup installation
- About the Shared Storage Option
- About Shared Storage Option components
- DELETE About reserving or releasing shared devices
- How to share robotic libraries without using the Shared Storage Option
- Shared Storage Option terms and concepts
- DELETE About the Shared Storage Option license
- About Shared Storage Option prerequisites
- About hardware configuration guidelines
- About installing and configuring drivers
- Verifying the connectivity
- DELETE About configuring the Shared Storage Option in NetBackup
- Verifying your Shared Storage Option configuration
- Device Monitor and Shared Storage Option
- Viewing SSO summary reports
- Operating system assistance
- Common configuration issues with Shared Storage Option
- Frequently asked questions about Shared Storage Option
- About the vm.conf configuration file
- ACS_mediatype entry in vm.conf
- ACS_SEL_SOCKET entry in vm.conf
- ACS_CSI_HOSTPORT entry in vm.conf (on UNIX)
- ACS_SSI_HOSTNAME entry in vm.conf
- ACS_SSI_INET_PORT entry in vm.conf (on UNIX)
- ACS_SSI_SOCKET entry in vm.conf
- ACS_TCP_RPCSERVICE / ACS_UDP_RPCSERVICE entry in vm.conf (on UNIX)
- ADJ_LSM entry in vm.conf
- API_BARCODE_RULES entry in vm.conf
- AUTHORIZATION_REQUIRED entry in vm.conf in NetBackup versions 8.0 and earlier
- AUTO_PATH_CORRECTION entry in vm.conf
- AUTO_UPDATE_ROBOT entry in vm.conf
- AVRD_PEND_DELAY entry in vm.conf
- AVRD_SCAN_DELAY entry in vm.conf
- CLEAN_REQUEST_TIMEOUT entry in vm.conf
- CLIENT_PORT_WINDOW entry in vm.conf
- CLUSTER_NAME entry in vm.conf
- DAYS_TO_KEEP_LOGS entry in vm.conf
- EMM_RETRY_COUNT entry in vm.conf
- EMM_CONNECT_TIMOUT entry in vm.conf
- EMM_REQUEST_TIMOUT entry in vm.conf
- ENABLE_ROBOT_AUTH entry in vm.conf
- INVENTORY_FILTER entry in vm.conf
- MAP_ID entry in vm.conf
- MAP_CONTINUE_TIMEOUT entry in vm.conf
- MEDIA_ID_BARCODE_CHARS entry in vm.conf
- MEDIA_ID_PREFIX entry in vm.conf
- MM_SERVER_NAME entry in vm.conf
- PREFERRED_GROUP entry in vm.conf
- RANDOM_PORTS entry in vm.conf
- REQUIRED_INTERFACE entry in vm.conf
- SERVER entry in vm.conf in NetBackup versions 8.0 and earlier
- SSO_DA_REREGISTER_INTERVAL entry in vm.conf
- SSO_DA_RETRY_TIMEOUT entry in vm.conf
- SSO_HOST_NAME entry in vm.conf
- VERBOSE entry in vm.conf
- Example vm.conf file
- How to access media and devices on other hosts
- Host name precedence in the vm.conf file
- Holds Management
- Menu user interfaces on UNIX
- About menu user interfaces
- About the tpconfig device configuration utility
- About the tpconfig utility menu
- Starting the tpconfig device configuration utility
- Adding robots
- Adding drives
- Updating a robot configuration
- Updating a drive configuration
- Deleting a robot
- Deleting a drive
- Configuring drive paths
- Configuring host credentials
- Displaying and writing the device configuration
- About the NetBackup Disk Configuration Utility
- Reference topics
- Host name rules
- About reading backup images with nbtar or tar32.exe
- Factors that affect backup time
- Methods for determining the NetBackup transfer rate
- NetBackup notify scripts
- backup_notify script
- backup_exit_notify script
- bpstart_notify script (UNIX clients)
- bpstart_notify.bat script (Windows clients)
- bpend_notify script (UNIX clients)
- bpend_notify.bat script (Windows clients)
- bpend_notify_busy script (UNIX clients)
- child_end_deployment_notify
- child_start_deployment_notify
- diskfull_notify script
- drive_mount_notify script (on UNIX)
- drive_unmount_notify script (on UNIX)
- mail_dr_info script
- media_deassign_notify script
- nbmail.cmd script (on Windows)
- parent_end_deployment_notify
- parent_end_notify script
- parent_start_deployment_notify
- parent_start_notify script
- pending_request_notify script
- restore_notify script
- session_notify script
- session_start_notify script
- shared_drive_notify script
- userreq_notify script
- Media and device management best practices
- About TapeAlert
- About tape drive cleaning
- How NetBackup selects drives
- How NetBackup reserves drives
- About SCSI persistent reserve
- About the SPC-2 SCSI reserve process
- About SCSI reserve requirements
- About SCSI reserve limitations
- About SCSI reservation logging
- About SCSI reserve operating system limitations on Windows
- About checking for data loss
- About checking for tape and driver configuration errors
- About configuring SCSI reserve
- How NetBackup selects media
- Volume pool and volume group examples
- Media formats
- Media and device management processes
- About Tape I/O commands on UNIX
- Index
About Shared Storage Option prerequisites
To configure your hardware for use with Shared Storage Option, you must ensure that the following prerequisites are satisfied:
Attach robots and drives.
Ensure that all of the servers recognize the shared devices. Device recognition may depend on operating system configuration, as follows:
On UNIX or Linux servers, you may have to modify configuration files, such as the sg driver on Solaris systems.
On Windows servers, Windows recognizes devices automatically. However, in some instances you may have to install device drivers.
Some of the following tasks may be optional depending on your hardware:
Determine the physical location of each drive within the robot. Location usually is shown on the connectors to the drives or in the vendor documentation.
This task may not be required if NetBackup device discovery accurately determines drive location within the robot.
Connect all drives and all robots.
Install SAN connecting hardware (for example, bridges, switches, or hubs).
If fiber is part of your configuration and you use a SCSI-to-fiber bridge, determine the SCSI-to-Fibre Channel mapping for your tape devices.
Hard-wired SCSI IDs are converted to Fibre Channel logical unit numbers (LUNs) that the hosts read. To ensure correct drive assignments, you should know which LUNs map to which physical SCSI IDs. Use persistent LUN mapping if possible.
Familiarity with the hardware and various vendor configuration tools help you accomplish this task. See the vendor documentation for your bridge.
Record the physical configuration.
When you set up a Shared Storage Option configuration, record your hardware information. Record the adapter, SCSI addresses, World Wide Names (WWNs), and Fibre Channel LUNs to which you connected each drive. Also, record the version levels of firmware and drivers.
Install and configure the appropriate drivers. See your vendor documentation for instructions.
On UNIX and Linux servers, create any device files that are needed. Depending on the operating system, a reconfiguration system start (boot -r) may create these files automatically.
Create the device files for each drive; use the Fibre Channel LUNs of the drives and adapters in the device file names. Add the names of the device files to your notes to complete the correlation between device files and physical drive location.
Use the NetBackup Device Configuration Guide and the man pages that are available with the operating system.
On UNIX and Linux servers, customize the operating system by modifying the appropriate system configuration files. This task requires knowledge of the system files that use the Shared Storage Option environment and their formats. For example, on Sun Solaris systems you may need to modify the sg, st, and HBA driver files.
Modify the HBA driver files to bind Fibre Channel devices (WWN) to a specific target ID. For procedures, see the operating system documentation.
For instructions on how to configure the HBA on Windows servers, see the HBA documentation from the vendor.
Use any available hardware configuration interface to configure and ensure that the configuration is what you expect. For example, on Windows servers you can use the Hyperterminal interface to configure SCSI-to-fibre bridges.
Use the following order when you configure and verify the hardware:
Robot and shared drives
Bridges
Hub or switches
Hosts
If errors occur and you suspect the operating system, refer to the operating system logs as described in your operating system documentation.