NetBackup IT Analytics Release Notes
- Introduction
- Patch release for version 11.2
- What's new: Version 11.2 highlights
- Supported Systems
- Installations and Upgrades
- Fixed issues
- Known Issues and Optimizations
11.2.01 patch release notes
The patch release includes all the previous patches of 11.1.xx and 11.2.xx patch fixes.
The following changes are included in this release.
Not applicable in this release.
Not applicable in this release.
Not applicable in this release.
Table: Enhancements and resolved issues
Issue Number | Description |
---|---|
SC-49870 | Resolves the data collection issue where incorrect VMware Operating System platform version was getting persisted. |
SC-50004 | Resolves the data collection failure issue with Brocade Switch Probe. The blade details, such as blade-id, was empty hence, NetBackup IT Analytics displayed NumberFormatException error message. |
SC-50299 | Resolves an issue with Cohesity DataProtect data collection to improve the handling of empty responses from the Cohesity REST API. Also includes an enhancement to support the collection of protected objects from VMTag based protection in Cohesity. |
SC-50497 | Resolves an issue of data collectors auto upgradation process. The data collectors were not getting upgraded when the portal was upgraded. |
Table: Enhancements and resolved issues
Issue Number | Description |
---|---|
SC-45026 | Resolves an issue with the Azure Cloud Cost Spend dashboard. NetBackup IT Analytics displayed discrepancies in the previous month's and current month's spend values. |
SC-49502 | Resolves an issue with System Notifications. NetBackup IT Analytics displayed APTARE_TBS_IDX_10M used over 90% (92), could not connect to Aptare cloud notification in the System Notification dialog box. |
SC-49610 | The Dell EMC NetWorker Backup & Recovery Data collector policy is enhanced when there is a dedicated authentication server configured for any Dell EMC NetWorker server in the datacenter. Two new fields, Authentication Server and Authentication Port are incorporated. Note: For more information, see NetBackup IT Analytics Data Collector Installation Guide for Backup Manager >> Pre-Installation setup for Dell EMC NetWorker backup & Recovery >> Adding a Dell EMC Networker Backup & Recovery Data Collector policy section. |
SC-49721 | Resolves an issue with Advance Parameter. NetBackup IT Analytics did not allow to configure advance parameter without any default value. |
SC-49725 | Resolves an issue of deleting an Advance Parameter. All the collectors and hosts were utilizing the configured default values instead of modified or a new advance parameter value. Moreover, the Networker Protector Details probes for all the networkers continued to use the default values on subsequent executions even when the parameters were erased / deleted from a collector OR totally removed from the portal parameters options. |
SC-49726 | Resolves an issue when an advanced parameter was deleted from portal. After deleting the advance parameter, data collector restart was required. Now, no restart of the data collector is required. |
SC-49794 | Resolves an issue with Data Collector Status Summary report. Although no EMC Data Domain Backup policy being implemented, NetBackup IT Analytics still displayed the data. |
SC-49565 | Quarterly Oracle 19c January 2023 Windows Patch is now available for installation. Note: For more information, see NetBackup IT Analytics Installation and Upgrade Guide for Windows >> Oracle patches for the database server >> Install Oracle 19c Windows January 2023 patch section. |
SC-49977 | Resolves an issue of prolonged execution of the saveHPDMediaList and saveHPDTapeDriveListStatus processes of HP Data Protection components. |
SC-50071 | Resolves an issue with SQL Template Designer dialog box. While creating a SQL query using ${freeCombo1}) field, the field value was getting replaced with -1, thus displaying an error. A new advance parameter portal.rtd.SQLParameterDefaultValue has been incorporated with default as 1. |
SC-50079 | Resolves the issue with EMC Data Domain Storage. If the parent path and folder path are same, StringIndexOutOfBoundsException error message was displayed. |
SC-50308 | Resolves an issue of deletion process of the decommissioned Brocade SAN switch. When user tried deleting decommissioned SAN switch, NetBackup IT Analytics displayed No Switch were deleted error message. |
SC-50411 | The Assign User Privileges in Users and Privileges module is enhanced to display Email on Schedule and Export on Schedule options for the Reports. |
SC-50430 | Resolves an issue with Brocade Switch policy using CLI as Collection Method. The Brocade Switch Details probe displayed Failed to store the data in the database error message. |
SC-50755 | The reports in NetBackup IT Analytics are enhanced. The report now displays Report generated on with current date and time at the bottom. Note: For more information, see NetBackup IT Analytics User Guide >> Work with the SQL template designer >> Format the SQL Template Output section. |
SC-50791 | Resolves an issue with File Analytics Data Collection Policy in Collector Administrator module. While adding a File Analytics policy from Collector Administrator, the use of a space in a folder name was not supported. |
SC-50792 | Resolves the following issues:
|
SC-50951 | The Reports module in the Admin section is enhance to display Backup SLA and Backup Windows for Foundation license. |
SC-50995 | Resolves an issue with Inventory Objects. The decommissioned servers were listed in the Inventory Objects despite deselecting the Show Decommissioned check box in the Configure Hierarchy Panel dialogue box. |
SC-51052 | Resolves an issue with Alert Scope dialog box, Jobs started in last(days)* section. The default alert for Hung Job took a long time because the scope was set to Jobs started in last days >= 14, instead of Job started in last days <= 14. This resulted in the Hung Job alert taking longer time for each iteration. |