NetBackup IT Analytics Certified Configuration Guide
- Introduction
- Portal and database servers
- Data Collector server configurations
- Capacity Manager configurations
- Supported systems and access requirements
- IBM Arrays: Modify profile
- Creating a NetApp user with API privileges
- Creating a NetApp cluster-mode user with API privileges
- Array/LUN performance Data Collection
- EMC Isilon array performance metrics
- NetApp Cluster-Mode performance metrics
- NetApp Cluster-Mode Aggregate Performance
- NetApp Cluster-Mode CIFS Performance
- NetApp Cluster-Mode Disk Performance
- NetApp Cluster-Mode Fiber Channel Protocol Logical Interface Performance
- NetApp Cluster-Mode LUN Performance
- NetApp Cluster-Mode NFS Performance
- NetApp Cluster-Mode Processor Node Performance
- NetApp Cluster-Mode Processor Performance
- NetApp Cluster-Mode RAID Performance
- NetApp Cluster-Mode SMB (Server Message Block) Performance
- NetApp Cluster-Mode System Performance
- NetApp Cluster-Mode Target Port Performance
- NetApp Cluster-Mode Volume Performance
- EMC Symmetrix enhanced performance metrics
- Create enhanced EMC Symmetrix Performance report templates
- EMC Symmetrix Array Performance
- EMC Symmetrix Backend Director Performance
- EMC Symmetrix Frontend Director Performance
- EMC Symmetrix Front-end Port Performance
- EMC Symmetrix Storage Group Performance
- EMC Symmetrix Database Performance
- EMC Symmetrix Disk Group Performance
- EMC Symmetrix Disk Performance
- EMC Symmetrix Device Groups Performance
- EMC Symmetrix Disk by Technology Performance
- EMC Symmetrix Storage Tier Performance
- EMC Symmetrix Thin Tier Performance
- EMC Symmetrix Thin Pool Performance
- EMC Symmetrix Enhanced Performance metrics
- Hitachi Vantara array performance metrics
- Host resources prerequisites and configurations
- Host access privileges, sudo commands, ports, and WMI proxy requirements
- WMI proxy requirements for Windows host Data Collection
- Host resources supported configurations
- Pure Storage Flash Array performance metrics
- Supported host bus adapters (HBAs)
- Compute Resources supported configurations
- Cloud configurations
- Virtualization Manager configurations
- File Analytics configurations
- Fabric Manager configurations
- Backup Manager configurations
- ServiceNow configurations
- Internal TCP port requirements
Array/LUN performance Data Collection
The following array families are supported for block storage LUN performance and port performance data collection.
See Array/LUN performance notes.
Table: Array Family
Array Family | Rd/Wrte IO/sec | Total IO/sec | Rd/WrteMB / sec | Rd/Wrte Cache Hits/sec | Rd/Wrte Respond(ms) | Total Respond(ms) |
|---|---|---|---|---|---|---|
Dell Compellent | X | X | X | X | -- | -- |
EMC VNX | X | Calc. | X | X | X | Calc. |
EMC Symmetrix | X | X | X | X | -- | -- |
EMC XtremIO | Calc. | Calc. | Calc. | -- | X | X |
HDS Tuning Manager | X | Calc. | X | X | X | X |
HP 3PAR | X | X | X | X | X | X |
IBM SVC | X | X | X | -- | -- | -- |
IBM XIV | X | X | X | X | X | X |
NetApp ONTAP 7-Mode (Block only) | X | Calc. | X | -- | -- | Avg Latency |
Pure Storage FlashArray | X | Calc. | X | -- | X | Calc. |
The following notes apply to array families are supported for block storage LUN performance and port performance data collection.
Table: Array families supporting block storage LUN performance and port performance data collection.
Array Family | Notes |
|---|---|
EMC VNX | The minimum FLARE OS version required to capture response times is 04.30.000.5.524 A11. Note that VNX (Block) will have completely different FLARE releases and all support the collection of the counter fields needed for capturing response time, starting with FLARE version 05.31.000.5.006 A01. Enable statistics logging on the VNX system. |
EMC XtremIO | For EMC XtremIO, the values obtained are averages over the time interval. The Read/Write/Total IOs and the Read/Write MBs are multiplied by the time interval and persisted. |
HDS Tuning Manager | For Hitachi arrays: To collect performance data from Hitachi Tuning Manager, the Data Collector must be installed on the same server as Tuning Manager. And, a single Data Collector policy must be used to collect both the capacity data from the Device Manager server and the performance data from the Tuning Manager server. |
NetApp ONTAP 7-Mode (Block only) | For NetApp ONTAP 7-Mode (Block only): Total response time is the average latency (ms) for all LUN read and write operations. Performance data is collected for both iSCSI LUNs and FC LUNs. |