Please enter search query.
Search <book_title>...
NetBackup IT Analytics Certified Configuration Guide
Last Published:
2024-02-22
Product(s):
NetBackup IT Analytics (11.2)
- Introduction
- Portal and database servers
- Data Collector server configurations
- Capacity Manager configurations
- Supported systems and access requirements
- IBM Arrays: Modify profile
- Creating a NetApp user with API privileges
- Creating a NetApp cluster-mode user with API privileges
- Array/LUN performance Data Collection
- EMC Isilon array performance metrics
- NetApp Cluster-Mode performance metrics
- NetApp Cluster-Mode Aggregate Performance
- NetApp Cluster-Mode CIFS Performance
- NetApp Cluster-Mode Disk Performance
- NetApp Cluster-Mode Fiber Channel Protocol Logical Interface Performance
- NetApp Cluster-Mode LUN Performance
- NetApp Cluster-Mode NFS Performance
- NetApp Cluster-Mode Processor Node Performance
- NetApp Cluster-Mode Processor Performance
- NetApp Cluster-Mode RAID Performance
- NetApp Cluster-Mode SMB (Server Message Block) Performance
- NetApp Cluster-Mode System Performance
- NetApp Cluster-Mode Target Port Performance
- NetApp Cluster-Mode Volume Performance
- EMC Symmetrix enhanced performance metrics
- Create enhanced EMC Symmetrix Performance report templates
- EMC Symmetrix Array Performance
- EMC Symmetrix Backend Director Performance
- EMC Symmetrix Frontend Director Performance
- EMC Symmetrix Front-end Port Performance
- EMC Symmetrix Storage Group Performance
- EMC Symmetrix Database Performance
- EMC Symmetrix Disk Group Performance
- EMC Symmetrix Disk Performance
- EMC Symmetrix Device Groups Performance
- EMC Symmetrix Disk by Technology Performance
- EMC Symmetrix Storage Tier Performance
- EMC Symmetrix Thin Tier Performance
- EMC Symmetrix Thin Pool Performance
- EMC Symmetrix Enhanced Performance metrics
- Hitachi Vantara array performance metrics
- Host resources prerequisites and configurations
- Host access privileges, sudo commands, ports, and WMI proxy requirements
- WMI proxy requirements for Windows host Data Collection
- Host resources supported configurations
- Pure Storage Flash Array performance metrics
- Supported host bus adapters (HBAs)
- Compute Resources supported configurations
- Cloud configurations
- Virtualization Manager configurations
- File Analytics configurations
- Fabric Manager configurations
- Backup Manager configurations
- ServiceNow configurations
- Internal TCP port requirements
EMC Symmetrix Frontend Director Performance
Table: EMC Symmetrix Frontend Director Performance
Metric | Description |
|---|---|
Percent Busy | The % of time that the director is busy. |
Host IOs | The number of host I/O operations per second for director data transfers. |
Host MBs | The size of the data transfer from the host in MB per second. |
Reqs | The data transfer read/write requests between the director and the cache. An I/O may require multiple requests depending on I/O size, alignment, or both. The requests rate should be either equal to or greater than the I/O rate. |
Read Response Time | A calculated average response time for reads. |
Write Response Time | A calculated average response time for writes. |