NetBackup IT Analytics Certified Configuration Guide
- Introduction
- Portal and database servers
- Data Collector server configurations
- Capacity Manager configurations
- Supported systems and access requirements
- IBM Arrays: Modify profile
- Creating a NetApp user with API privileges
- Creating a NetApp cluster-mode user with API privileges
- Array/LUN performance Data Collection
- EMC Isilon array performance metrics
- NetApp Cluster-Mode performance metrics
- NetApp Cluster-Mode Aggregate Performance
- NetApp Cluster-Mode CIFS Performance
- NetApp Cluster-Mode Disk Performance
- NetApp Cluster-Mode Fiber Channel Protocol Logical Interface Performance
- NetApp Cluster-Mode LUN Performance
- NetApp Cluster-Mode NFS Performance
- NetApp Cluster-Mode Processor Node Performance
- NetApp Cluster-Mode Processor Performance
- NetApp Cluster-Mode RAID Performance
- NetApp Cluster-Mode SMB (Server Message Block) Performance
- NetApp Cluster-Mode System Performance
- NetApp Cluster-Mode Target Port Performance
- NetApp Cluster-Mode Volume Performance
- EMC Symmetrix enhanced performance metrics
- Create enhanced EMC Symmetrix Performance report templates
- EMC Symmetrix Array Performance
- EMC Symmetrix Backend Director Performance
- EMC Symmetrix Frontend Director Performance
- EMC Symmetrix Front-end Port Performance
- EMC Symmetrix Storage Group Performance
- EMC Symmetrix Database Performance
- EMC Symmetrix Disk Group Performance
- EMC Symmetrix Disk Performance
- EMC Symmetrix Device Groups Performance
- EMC Symmetrix Disk by Technology Performance
- EMC Symmetrix Storage Tier Performance
- EMC Symmetrix Thin Tier Performance
- EMC Symmetrix Thin Pool Performance
- EMC Symmetrix Enhanced Performance metrics
- Hitachi Vantara array performance metrics
- Host resources prerequisites and configurations
- Host access privileges, sudo commands, ports, and WMI proxy requirements
- WMI proxy requirements for Windows host Data Collection
- Host resources supported configurations
- Pure Storage Flash Array performance metrics
- Supported host bus adapters (HBAs)
- Compute Resources supported configurations
- Cloud configurations
- Virtualization Manager configurations
- File Analytics configurations
- Fabric Manager configurations
- Backup Manager configurations
- ServiceNow configurations
- Internal TCP port requirements
Switch vendors
Note:
Refer to the Software and hardware disclaimer supported and tested by Veritas.
Fabric Manager provides reports that include topological views of the interrelationships of objects attached to the switches--end-to-end paths for objects such as LUNs and File Systems. Fabric Manager can collect data for the following switches.
Table: Switch information to collect
Vendor | Agent/Interface | Notes |
|---|---|---|
Brocade | Preferred SMI Integrated Agents:
REST API exposed by Brocade Switches with FOS version - 8.1.x and above and 9.0.x Collection Method: Command Line Interface (CLI) exposed by Brocade Switches with Brocade FOS versions 7.4.x, 8.x, 9.0.x |
Brocade Server Address*: This field is enabled if Collection Method is Command Line Interface (CLI). Specify only one Principal Switch IP address or fully qualified one Switch name for the Brocade Switch. Note: The port number is optional. The format should be: <ip_address>[:port_number]. Note: When collection method is Command Line Interface, TCP port 22 and UDP port 161 on Brocade Switch must be open, and those must be accessible to Data Collector. |
Cisco | Preferred SMI Agent:
|
|