Veritas NetBackup™ Appliance 命令参考指南
- 概述
- 附录 A. Main > Appliance 命令
- 附录 B. Main > Manage > FibreChannel 命令
- 附录 C. Main > Manage > HighAvailability 命令
- 附录 D. Main > Manage > Libraries 命令
- 附录 E. Main > Manage > Libraries > Advanced > ACS 命令
- Manage > Libraries > Advanced > ACS > ACS_CSI_HOSTPORT
- Manage > Libraries > Advanced > ACS > ACS_SEL_SOCKET
- Manage > Libraries > Advanced > ACS > ACS_SSI_HOSTNAME
- Manage > Libraries > Advanced > ACS > ACS_SSI_INET_PORT
- Manage > Libraries > Advanced > ACS > ACS_SSI_SOCKET
- Manage > Libraries > Advanced > ACS > ACS_TCP_RPCSERVICE
- Manage > Libraries > Advanced > ACS > ACS_UDP_RPCSERVICE
- Manage > Libraries > Advanced > ACS > API_BARCODE_RULES
- Manage > Libraries > Advanced > ACS > TestACS
- Manage > Libraries > Advanced > ACS > ViewVMconf
- 附录 F. Main > Manage > License 命令
- 附录 G. Main > Manage > MountPoints 命令
- 附录 H. Main > Manage > NetBackup CLI 命令
- 附录 I. Main > Manage > OpenStorage 命令
- 附录 J. Main > Manage > Software 命令
- Manage > Software > Cancel
- Manage > Software > Delete
- Manage > Software > Download
- Manage > Software > DownloadProgress
- Manage > Software > Firmware
- Manage > Software > Install
- Manage > Software > List
- Manage > Software > Readme
- Manage > Software > Rollback
- Manage > Software > Share
- Manage > Software > UpgradeStatus
- Manage > Software > VxUpdate
- 附录 K. Main > Manage > Storage 命令
- 附录 L. Main > Manage > Tapes 命令
- 附录 M. Main > Manage > Certificates 命令
- 附录 N. Main > Monitor 命令
- 附录 O. Main > Network 命令
- Network > Configure
- Network > Date
- Network > DNS
- Network > Gateway
- Network > Hostname
- Network > Hosts
- Network > IPv4
- Network > IPv6
- Network > LinkAggregation
- Network > NetStat
- Network > NTPServer
- Network > Ping
- Network > SetProperty
- Network > Show
- Network > TimeZone
- Network > TraceRoute
- Network > Unconfigure
- Network > VLAN
- Network > WANOptimization
- 附录 P. Main > Network > Security 命令 (IPsec)
- 附录 Q. Main > Reports 命令
- 附录 R. Main > Settings 命令
- Settings > Cloud
- Settings > Deduplication
- Settings > FibreTransport
- Settings > iSCSI > Initiator
- Settings > iSCSI > Interface
- Settings > iSCSI > Target
- Settings > LogForwarding
- Settings > LifeCycle
- Settings > NetBackup
- Settings > Password
- Settings > Share
- Settings > SNMP polling
- Settings > Sysctl
- Settings > SystemLocale
- Settings > NetBackup DNAT
- 附录 S. Main > Settings > Alerts 命令
- 附录 T. Main > Settings > Notifications 视图命令
- 附录 U. Main > Settings > Security 命令
- Settings > Security > Authorization
- Settings > Security > Authentication > ActiveDirectory
- Settings > Security > Authentication > Kerberos
- Settings > Security > Authentication > LDAP
- Settings > Security > Authentication > LocalUser
- Main > Settings > Security > Certificate
- Main > Settings > Security > FIPS
- Main > Settings > Security > Ports
- Main > Settings > Security > STIG
- 附录 V. Main > Support 命令
- Support > Checkpoint
- Support > Cleanup > RemoveShelfEntries
- Support > Cleanup > ResetDIMMErrors
- Support > Collect
- Support > DataCollect
- Support > Disk
- Support > Errors
- Support > FactoryReset
- Support > FibreTransport
- Support > InfraServices
- Support > iostat
- Support > IPMI
- Support > KillRemoteCall
- Support > Logs
- Support > Maintenance
- Support > Messages
- Support > NBDNA
- Support > nbperfchk
- Support > NBSU
- Support > Processes
- Support > RAID
- Support > Reboot
- Support > RecoverStorage
- Support > Service
- Support > ServiceAllowed
- Support > Show
- Support > Shutdown
- Support > Storage ClearReservations
- Support > Storage Reset
- Support > Storage SanityCheck
- Support > Test
名称
Main > Manage > FibreChannel > Show — 用于查看 FC HBA 卡的端口和设备配置。
大纲
Show [端口]
描述
使用此命令可查看此设备的 FC HBA 卡的端口和设备配置。
选项
- Show Ports
使用此命令可仅查看此设备的 FC HBA 卡的端口信息。
端口信息包括以下内容:
总线 ID
插槽位置 (1-6)
端口位置 (1-2)
端口全球通用名称 (WWN)
状态
联机
脱机
结构
已断开
链接失效
循环
Ptp
物理状态(启动器或目标)
配置类型
启动器- 已标记为标准启动器端口。
目标 (FTMS) - 已标记为 SAN 客户端 FTMS 目标端口。
目标 (MSDP) - 已标记为用于从其他 NetBackup 52xx 或 53xx 设备复制数据的目标端口。
速度
远程端口
Physical State 列显示 HBA 端口的实际状态。
Configuration Type 列显示用户指定的端口模式。如果用户尚未做出更改,则显示默认端口类型配置。
启用 FC 功能时,标记为该功能目标端口的端口将进入目标模式。启用操作之前,端口处于标准启动器模式,显示 Initiator 的实际物理状态。
通过对 Configuration Type 和 Physical State 列进行比较,可确定是否启用了相关 FC 功能。
- Show
使用此命令可查看此设备的以下 FC HBA 卡的端口和设备配置:
光纤传输介质服务器 (FTMS) 的配置状态
HBA 卡的配置状态和卡名称
是否加载了驱动程序
端口信息
设备信息
通过 FC 的远程设备
注意:
如果看不到为此设备配置的目标设备,请使用 Main> Manage> FibreChannel> Scan 并再次运行 Show 命令扫描通过 FC 的远程设备。
示例
下面是运行 Main> Manage> FibreChannel> Show 命令时的信息示例。
appliance.FC> Show
- [Info] FTMS mode: none
- [Info] Fibre Transport Deduplication state: disabled
**** FC HBA Cards ****
08:00.0 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel to PCI Express HBA (rev 02)
08:00.1 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel to PCI Express HBA (rev 02)
**** Drivers ****
qla2xxx is loaded
windrvr6 is not loaded
qla2x00tgt is loaded
scst is loaded
scst_user is loaded
**** Ports ****
BusID Slot Port Port WWN Status PhysicalState ConfigurationType Speed Remote Ports
08:00.0 Slot6 1 21:00:00:24:FF:88:1E:52 Online Initiator Initiator 8 gbit/s 0x21000024ff8cd275
0x21000024ff8cd265
08:00.1 Slot6 2 21:00:00:24:FF:88:1E:53 Online Initiator Target(MSDP) 8 gbit/s 0x21000024ff8cd274
0x21000024ff8cd264
**** Devices ****
Device Vendor ID Type Remote Port
/dev/sg11 VERITAS TEST-NET-2 FCPIPE (Dedup Target) 0x21000024ff8cd265
/dev/sg12 VERITAS TEST-NET-2 FCPIPE (Dedup Target) 0x21000024ff8cd275
**** Remote Appliances over FC ****
The result is based on the scan at December 28 2015 Monday 06:01:35 PST
/dev/sg11 203.0.113.0
98.51.100.0(TEST-NET-2.veritas.com)
/dev/sg12 203.0.113.0
98.51.100.0(TEST-NET-2.veritas.com)