Veritas NetBackup™ Appliance 命令参考指南
- 概述
 - 附录 A. Main > Appliance 命令
 - 附录 B. Main > Manage > FibreChannel 命令
 - 附录 C. Main > Manage > HighAvailability 命令
 - 附录 D. Main > Manage > Libraries 命令
 - 附录 E. Main > Manage > Libraries > Advanced > ACS 命令
- Manage > Libraries > Advanced > ACS > ACS_CSI_HOSTPORT
 - Manage > Libraries > Advanced > ACS > ACS_SEL_SOCKET
 - Manage > Libraries > Advanced > ACS > ACS_SSI_HOSTNAME
 - Manage > Libraries > Advanced > ACS > ACS_SSI_INET_PORT
 - Manage > Libraries > Advanced > ACS > ACS_SSI_SOCKET
 - Manage > Libraries > Advanced > ACS > ACS_TCP_RPCSERVICE
 - Manage > Libraries > Advanced > ACS > ACS_UDP_RPCSERVICE
 - Manage > Libraries > Advanced > ACS > API_BARCODE_RULES
 - Manage > Libraries > Advanced > ACS > TestACS
 - Manage > Libraries > Advanced > ACS > ViewVMconf
 
 - 附录 F. Main > Manage > License 命令
 - 附录 G. Main > Manage > MountPoints 命令
 - 附录 H. Main > Manage > NetBackup CLI 命令
 - 附录 I. Main > Manage > OpenStorage 命令
 - 附录 J. Main > Manage > Software 命令
- Manage > Software > Cancel
 - Manage > Software > Delete
 - Manage > Software > Download
 - Manage > Software > DownloadProgress
 - Manage > Software > Firmware
 - Manage > Software > Install
 - Manage > Software > List
 - Manage > Software > Readme
 - Manage > Software > Rollback
 - Manage > Software > Share
 - Manage > Software > UpgradeStatus
 - Manage > Software > VxUpdate
 
 - 附录 K. Main > Manage > Storage 命令
 - 附录 L. Main > Manage > Tapes 命令
 - 附录 M. Main > Manage > Certificates 命令
 - 附录 N. Main > Monitor 命令
 - 附录 O. Main > Network 命令
- Network > Configure
 - Network > Date
 - Network > DNS
 - Network > Gateway
 - Network > Hostname
 - Network > Hosts
 - Network > IPv4
 - Network > IPv6
 - Network > LinkAggregation
 - Network > NetStat
 - Network > NTPServer
 - Network > Ping
 - Network > SetProperty
 - Network > Show
 - Network > TimeZone
 - Network > TraceRoute
 - Network > Unconfigure
 - Network > VLAN
 - Network > WANOptimization
 
 - 附录 P. Main > Network > Security 命令 (IPsec)
 - 附录 Q. Main > Reports 命令
 - 附录 R. Main > Settings 命令
- Settings > Cloud
 - Settings > Deduplication
 - Settings > FibreTransport
 - Settings > iSCSI > Initiator
 - Settings > iSCSI > Interface
 - Settings > iSCSI > Target
 - Settings > LogForwarding
 - Settings > LifeCycle
 - Settings > NetBackup
 - Settings > Password
 - Settings > Share
 - Settings > SNMP polling
 - Settings > Sysctl
 - Settings > SystemLocale
 - Settings > NetBackup DNAT
 
 - 附录 S. Main > Settings > Alerts 命令
 - 附录 T. Main > Settings > Notifications 视图命令
 - 附录 U. Main > Settings > Security 命令
- Settings > Security > Authorization
 - Settings > Security > Authentication > ActiveDirectory
 - Settings > Security > Authentication > Kerberos
 - Settings > Security > Authentication > LDAP
 - Settings > Security > Authentication > LocalUser
 - Main > Settings > Security > Certificate
 - Main > Settings > Security > FIPS
 - Main > Settings > Security > Ports
 - Main > Settings > Security > STIG
 
 - 附录 V. Main > Support 命令
- Support > Checkpoint
 - Support > Cleanup > RemoveShelfEntries
 - Support > Cleanup > ResetDIMMErrors
 - Support > Collect
 - Support > DataCollect
 - Support > Disk
 - Support > Errors
 - Support > FactoryReset
 - Support > FibreTransport
 - Support > InfraServices
 - Support > iostat
 - Support > IPMI
 - Support > KillRemoteCall
 - Support > Logs
 - Support > Maintenance
 - Support > Messages
 - Support > NBDNA
 - Support > nbperfchk
 - Support > NBSU
 - Support > Processes
 - Support > RAID
 - Support > Reboot
 - Support > RecoverStorage
 - Support > Service
 - Support > ServiceAllowed
 - Support > Show
 - Support > Shutdown
 - Support > Storage ClearReservations
 - Support > Storage Reset
 - Support > Storage SanityCheck
 - Support > Test
 
 
名称
Main > Settings > Alerts > SNMP — 在设备上添加 SNMP 信息,该信息使主机能够发送针对监视的 SNMP 通知。
大纲
SNMP Disable 
SNMP Enable 
SNMP Set Server[Community][Port] 
SNMP Show 
SNMP ShowMIB 
描述
NetBackup appliance 使用 SNMPv2-SMI 应用程序协议来监视设备。使用此命令可在服务器上添加或更改 SNMP 参数。可以使用以下命令显示当前参数以及对 SNMP 信息所做的更改。可以使用此命令启用和禁用针对设备监视的 SNMP 通知。
创建并启用 SNMP 社区后,即可在该设备上通过 SNMP 协议进行设备监视。对通知或陷阱进行了编程,使其发生在设备上。此外,可以使用此命令查看已为该设备配置的通知陷阱。
以下列表是针对该设备通过 SNMP 监视的硬件通知类型的示例:
CPU
磁盘
风扇
光纤通道
电源
RAID
温度
选项
- SNMP Disable
 禁用发送针对监视的 SNMP 通知(陷阱)的功能。
- SNMP Enable
 启用发送针对监视的 SNMP 通知(陷阱)的功能。
- SNMP Set Server [Community] [Port]
 添加有关 SNMP 的信息。其中 Server 是 SNMP 服务器的名称,[Community] 是 SNMP 团体,[Port] 是 SNMP 端口。
注意:
NetBackup appliance 支持市场上的所有 SNMP 服务器。但是,ManageEngine™ SNMP 服务器和 HP OpenView SNMP 服务器仅通过针对 2.6 及更高版本的测试和认证。
- SNMP Show
 显示在您运行 SNMP Set Server 命令之后设置的参数。如果在运行 SNMP SetServer 命令之前运行此命令,则会显示 [Community] 和 [Port] 的默认值,但不显示 Server 的值。
- SNMP ShowMIB
 显示管理信息库 (MIB) 文件的内容。此文件包含配置用于监视设备的通知陷阱。
示例
可以使用以下任一方法在端口 8080 上配置公用 SNMP 团体。 该示例使用 [Community] 和 [Port] 选项。
abc123.Alerts> SNMP Set pqr222.xyz.com public 8080 Successfully set SNMP manager
运行 Settings> Alerts > SNMP ShowMIB 命令时,将显示类似以下内容的输出。
VERITAS-APPLIANCE-MONITORING-MIB DEFINITIONS ::= BEGIN
	 
	  IMPORTS 
	    DisplayString, mib-2 FROM RFC1213-MIB
	    enterprises, OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI;
	 
	  
	  applianceMonitoringMib MODULE-IDENTITY
	  LAST-UPDATED "2016083000Z"
	  ORGANIZATION "Veritas Technologies LLC"
	  CONTACT-INFO "500 East Middlefield Road
	                Mountain View, CA 94043 US
	                Subject: appliance.mib"
	  DESCRIPTION  "The MIB module for Veritas Appliance Monitoring"
	 
 	 REVISION     "201609060000Z"
 	 DESCRIPTION  "Changed symc strings to vrts."
	 
	  ::= { products 9 }
	  
	  veritassoftware          OBJECT IDENTIFIER ::= { enterprises 48328 }
	  products                  OBJECT IDENTIFIER ::= { veritassoftware 3 }
	 
	  systems                   OBJECT IDENTIFIER ::= { applianceMonitoringMib 1 }
	  software                  OBJECT IDENTIFIER ::= { applianceMonitoringMib 2 }
	  
	-- system traps 
	 
	  vrtssystemName OBJECT-TYPE
	    SYNTAX DisplayString (SIZE(0..80))
	    MAX-ACCESS read-only
	    STATUS current 
	    DESCRIPTION "System Name"
	  ::= { systems 1 }
	 
	  vrtsfanTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps fan failures"
	  ::= { systems 3 }
	 
	  vrtspowerTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps power failures"
	  ::= { systems 4 }
	 
	  vrtsfibrechannelTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps FibreChannel failures"
	  ::= { systems 5 }
	 
	  vrtstemperatureTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps temperature failures"
	  ::= { systems 6 }
	 
	  vrtscpuTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps cpu failures"
	  ::= { systems 7 }
	 
	  vrtsdiskTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps disk failures"
	  ::= { systems 8 }
	 
	  vrtsraidgroupTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps raid failures"
	  ::= { systems 9 }
	 
	 
	  vrtsenclosurefanTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps enclosure fan failures"
	  ::= { systems 10 }
	 
	  vrtsenclosurepowerTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps enclosure power failures"
	  ::= { systems 11 }
	 
	  vrtsenclosuretemperatureTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps enclosure temperature failures"
	  ::= { systems 12 }
	 
	  vrtsenclosurediskTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps enclosure disk failures"
	  ::= { systems 13 }
	 
	  vrtsadapterTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps adapter failures"
	  ::= { systems 14 }
	 
	  vrtsfirmwareTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps firmware failures"
	  ::= { systems 15 }
	  
	  vrtspciTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps pci failures"
	  ::= { systems 16 }
	  
	  vrtsnetworkcardTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps network card failures"
	  ::= { systems 17 }
	 
	  vrtsvolumeTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps volume failures"
	  ::= { systems 18 }
	 
	  vrtsbbuTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps BBU failures"
	  ::= { systems 19 }
	  
	  vrtsconnectionTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps connection failures"
	  ::= { systems 20 }
	 
	  vrtspartitionTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Partition alert traps"
	  ::= { systems 21 }
	 
	  vrtsstoragestatusTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps StorageArray HealthStatus failures"
	  ::= { systems 22 }
	  
	  vrtsdimmTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Traps Dimm failures"
	  ::= { systems 23 }
	 
	-- software traps
	 
	  vrtsfailedJobsTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Job failures Trap"
	  ::= { software 1 }
	 
	  vrtsprocessTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Processes stopped traps"
	  ::= { software 2 }
	 
	  vrtsdiskSpaceTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Low disk space traps"
	  ::= { software 3 }
	  
	  vrtssoftwareUpdateSuccessTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Software update success trap"
	  ::= { software 4 }
	  
	  vrtssoftwareUpdateFailedRollbackSuccessTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Software update failed but rollback was successful trap"
	  ::= { software 5 }
	  
	  vrtssoftwareUpdateFailedRollbackFailedTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Software update and rollback failed trap"
	  ::= { software 6 }
	  
	  vrtsrollbackSuccessTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Software rollback success trap"
	  ::= { software 7 }
	  
	  vrtsrollbackFailedTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Software rollback failed trap"
	  ::= { software 8 }
	  
	  vrtsclusterStateTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Cluster node failed trap"
	  ::= { software 9 }
	  
	  vrtsdiskPerfTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Disk performance alert trap"
	  ::= { software 10 }
	  
	  vrtscollectorserviceTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
	    DESCRIPTION "Collector plugin loading failed trap"
	  ::= { software 11 }
	  
	  vrtshaclusternameTrap NOTIFICATION-TYPE
	    OBJECTS { vrtssystemName }
	    STATUS current
 	    DESCRIPTION "HA cluster name trap"
	  ::= { software 12 }
	  
	END