Veritas NetBackup™ Appliance 命令参考指南
- 概述
- 附录 A. Main > Appliance 命令
- 附录 B. Main > Manage > FibreChannel 命令
- 附录 C. Main > Manage > HighAvailability 命令
- 附录 D. Main > Manage > Libraries 命令
- 附录 E. Main > Manage > Libraries > Advanced > ACS 命令
- Manage > Libraries > Advanced > ACS > ACS_CSI_HOSTPORT
- Manage > Libraries > Advanced > ACS > ACS_SEL_SOCKET
- Manage > Libraries > Advanced > ACS > ACS_SSI_HOSTNAME
- Manage > Libraries > Advanced > ACS > ACS_SSI_INET_PORT
- Manage > Libraries > Advanced > ACS > ACS_SSI_SOCKET
- Manage > Libraries > Advanced > ACS > ACS_TCP_RPCSERVICE
- Manage > Libraries > Advanced > ACS > ACS_UDP_RPCSERVICE
- Manage > Libraries > Advanced > ACS > API_BARCODE_RULES
- Manage > Libraries > Advanced > ACS > TestACS
- Manage > Libraries > Advanced > ACS > ViewVMconf
- 附录 F. Main > Manage > License 命令
- 附录 G. Main > Manage > MountPoints 命令
- 附录 H. Main > Manage > NetBackup CLI 命令
- 附录 I. Main > Manage > OpenStorage 命令
- 附录 J. Main > Manage > Software 命令
- Manage > Software > Cancel
- Manage > Software > Delete
- Manage > Software > Download
- Manage > Software > DownloadProgress
- Manage > Software > Firmware
- Manage > Software > Install
- Manage > Software > List
- Manage > Software > Readme
- Manage > Software > Rollback
- Manage > Software > Share
- Manage > Software > UpgradeStatus
- Manage > Software > VxUpdate
- 附录 K. Main > Manage > Storage 命令
- 附录 L. Main > Manage > Tapes 命令
- 附录 M. Main > Manage > Certificates 命令
- 附录 N. Main > Monitor 命令
- 附录 O. Main > Network 命令
- Network > Configure
- Network > Date
- Network > DNS
- Network > Gateway
- Network > Hostname
- Network > Hosts
- Network > IPv4
- Network > IPv6
- Network > LinkAggregation
- Network > NetStat
- Network > NTPServer
- Network > Ping
- Network > SetProperty
- Network > Show
- Network > TimeZone
- Network > TraceRoute
- Network > Unconfigure
- Network > VLAN
- Network > WANOptimization
- 附录 P. Main > Network > Security 命令 (IPsec)
- 附录 Q. Main > Reports 命令
- 附录 R. Main > Settings 命令
- Settings > Cloud
- Settings > Deduplication
- Settings > FibreTransport
- Settings > iSCSI > Initiator
- Settings > iSCSI > Interface
- Settings > iSCSI > Target
- Settings > LogForwarding
- Settings > LifeCycle
- Settings > NetBackup
- Settings > Password
- Settings > Share
- Settings > SNMP polling
- Settings > Sysctl
- Settings > SystemLocale
- Settings > NetBackup DNAT
- 附录 S. Main > Settings > Alerts 命令
- 附录 T. Main > Settings > Notifications 视图命令
- 附录 U. Main > Settings > Security 命令
- Settings > Security > Authorization
- Settings > Security > Authentication > ActiveDirectory
- Settings > Security > Authentication > Kerberos
- Settings > Security > Authentication > LDAP
- Settings > Security > Authentication > LocalUser
- Main > Settings > Security > Certificate
- Main > Settings > Security > FIPS
- Main > Settings > Security > Ports
- Main > Settings > Security > STIG
- 附录 V. Main > Support 命令
- Support > Checkpoint
- Support > Cleanup > RemoveShelfEntries
- Support > Cleanup > ResetDIMMErrors
- Support > Collect
- Support > DataCollect
- Support > Disk
- Support > Errors
- Support > FactoryReset
- Support > FibreTransport
- Support > InfraServices
- Support > iostat
- Support > IPMI
- Support > KillRemoteCall
- Support > Logs
- Support > Maintenance
- Support > Messages
- Support > NBDNA
- Support > nbperfchk
- Support > NBSU
- Support > Processes
- Support > RAID
- Support > Reboot
- Support > RecoverStorage
- Support > Service
- Support > ServiceAllowed
- Support > Show
- Support > Shutdown
- Support > Storage ClearReservations
- Support > Storage Reset
- Support > Storage SanityCheck
- Support > Test
名称
Main > Settings > Alerts > SNMP — 在设备上添加 SNMP 信息,该信息使主机能够发送针对监视的 SNMP 通知。
大纲
SNMP Disable
SNMP Enable
SNMP Set Server[Community][Port]
SNMP Show
SNMP ShowMIB
描述
NetBackup appliance 使用 SNMPv2-SMI 应用程序协议来监视设备。使用此命令可在服务器上添加或更改 SNMP 参数。可以使用以下命令显示当前参数以及对 SNMP 信息所做的更改。可以使用此命令启用和禁用针对设备监视的 SNMP 通知。
创建并启用 SNMP 社区后,即可在该设备上通过 SNMP 协议进行设备监视。对通知或陷阱进行了编程,使其发生在设备上。此外,可以使用此命令查看已为该设备配置的通知陷阱。
以下列表是针对该设备通过 SNMP 监视的硬件通知类型的示例:
CPU
磁盘
风扇
光纤通道
电源
RAID
温度
选项
- SNMP Disable
禁用发送针对监视的 SNMP 通知(陷阱)的功能。
- SNMP Enable
启用发送针对监视的 SNMP 通知(陷阱)的功能。
- SNMP Set Server [Community] [Port]
添加有关 SNMP 的信息。其中 Server 是 SNMP 服务器的名称,[Community] 是 SNMP 团体,[Port] 是 SNMP 端口。
注意:
NetBackup appliance 支持市场上的所有 SNMP 服务器。但是,ManageEngine™ SNMP 服务器和 HP OpenView SNMP 服务器仅通过针对 2.6 及更高版本的测试和认证。
- SNMP Show
显示在您运行 SNMP Set Server 命令之后设置的参数。如果在运行 SNMP SetServer 命令之前运行此命令,则会显示 [Community] 和 [Port] 的默认值,但不显示 Server 的值。
- SNMP ShowMIB
显示管理信息库 (MIB) 文件的内容。此文件包含配置用于监视设备的通知陷阱。
示例
可以使用以下任一方法在端口 8080 上配置公用 SNMP 团体。 该示例使用 [Community] 和 [Port] 选项。
abc123.Alerts> SNMP Set pqr222.xyz.com public 8080 Successfully set SNMP manager
运行 Settings> Alerts > SNMP ShowMIB 命令时,将显示类似以下内容的输出。
VERITAS-APPLIANCE-MONITORING-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString, mib-2 FROM RFC1213-MIB
enterprises, OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI;
applianceMonitoringMib MODULE-IDENTITY
LAST-UPDATED "2016083000Z"
ORGANIZATION "Veritas Technologies LLC"
CONTACT-INFO "500 East Middlefield Road
Mountain View, CA 94043 US
Subject: appliance.mib"
DESCRIPTION "The MIB module for Veritas Appliance Monitoring"
REVISION "201609060000Z"
DESCRIPTION "Changed symc strings to vrts."
::= { products 9 }
veritassoftware OBJECT IDENTIFIER ::= { enterprises 48328 }
products OBJECT IDENTIFIER ::= { veritassoftware 3 }
systems OBJECT IDENTIFIER ::= { applianceMonitoringMib 1 }
software OBJECT IDENTIFIER ::= { applianceMonitoringMib 2 }
-- system traps
vrtssystemName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System Name"
::= { systems 1 }
vrtsfanTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps fan failures"
::= { systems 3 }
vrtspowerTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps power failures"
::= { systems 4 }
vrtsfibrechannelTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps FibreChannel failures"
::= { systems 5 }
vrtstemperatureTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps temperature failures"
::= { systems 6 }
vrtscpuTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps cpu failures"
::= { systems 7 }
vrtsdiskTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps disk failures"
::= { systems 8 }
vrtsraidgroupTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps raid failures"
::= { systems 9 }
vrtsenclosurefanTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps enclosure fan failures"
::= { systems 10 }
vrtsenclosurepowerTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps enclosure power failures"
::= { systems 11 }
vrtsenclosuretemperatureTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps enclosure temperature failures"
::= { systems 12 }
vrtsenclosurediskTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps enclosure disk failures"
::= { systems 13 }
vrtsadapterTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps adapter failures"
::= { systems 14 }
vrtsfirmwareTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps firmware failures"
::= { systems 15 }
vrtspciTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps pci failures"
::= { systems 16 }
vrtsnetworkcardTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps network card failures"
::= { systems 17 }
vrtsvolumeTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps volume failures"
::= { systems 18 }
vrtsbbuTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps BBU failures"
::= { systems 19 }
vrtsconnectionTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps connection failures"
::= { systems 20 }
vrtspartitionTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Partition alert traps"
::= { systems 21 }
vrtsstoragestatusTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps StorageArray HealthStatus failures"
::= { systems 22 }
vrtsdimmTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Traps Dimm failures"
::= { systems 23 }
-- software traps
vrtsfailedJobsTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Job failures Trap"
::= { software 1 }
vrtsprocessTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Processes stopped traps"
::= { software 2 }
vrtsdiskSpaceTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Low disk space traps"
::= { software 3 }
vrtssoftwareUpdateSuccessTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Software update success trap"
::= { software 4 }
vrtssoftwareUpdateFailedRollbackSuccessTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Software update failed but rollback was successful trap"
::= { software 5 }
vrtssoftwareUpdateFailedRollbackFailedTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Software update and rollback failed trap"
::= { software 6 }
vrtsrollbackSuccessTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Software rollback success trap"
::= { software 7 }
vrtsrollbackFailedTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Software rollback failed trap"
::= { software 8 }
vrtsclusterStateTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Cluster node failed trap"
::= { software 9 }
vrtsdiskPerfTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Disk performance alert trap"
::= { software 10 }
vrtscollectorserviceTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "Collector plugin loading failed trap"
::= { software 11 }
vrtshaclusternameTrap NOTIFICATION-TYPE
OBJECTS { vrtssystemName }
STATUS current
DESCRIPTION "HA cluster name trap"
::= { software 12 }
END