Veritas NetBackup™ Flex Scale Best Practices and Troubleshooting Guide
- Introduction
- Configuration requirements
- Best practices
- NetBackup Flex Scale tuning and sizing
- Troubleshooting NetBackup Flex Scale
- NetBackup Flex Scale logs
- Services management
- Audit logs
- Collecting logs for cluster nodes
- Error messages displayed during the pre-upgrade check
- Troubleshooting NetBackup Flex Scale issues
- If cluster configuration fails (for example because an IP address that was already in use is specified) and you try to reconfigure the cluster, the UI displays an error but the configuration process continues to run
- Validation error while adding VMware credentials to NetBackup
- NetBackup Web UI incorrectly displays some NetBackup Flex Scale processes as failed
- Unable to create BMR Shared Resource Tree (SRT) on NetBackup Flex Scale Appliance
- NetBackup configuration files are not persistent across operations that require restarting the system
- Connection timeout errors during patch installs, upgrades, and rollback operations
- Initial configuration wizard displays a driver node not selected error
- Initial configuration wizard displays a license error after successfully configuring the cluster
Physical environment
NetBackup Flex Scale nodes must remain unopened and stored in the same location, preferably the datacenter. If cardboard is not allowed in the datacenter, specify where the equipment will be located on the day of installation.
American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) A3 and A4 Standards.
Operating temperature: (+10°C to +35°C) (+50°F to +95°F)
Non-operating temperature: (-30°C to +60°C) (-22°F to +140°F)
Operating humidity of Appliance: (8% RH to 90% RH)
Non-operating humidity: (5% RH to 95% RH)
Power Cable Specifications: IEC 60320 C14 To IEC 60320 C13 - AC 250 V - 10 A - 6.6 Ft - Black
AC power requirements:
100 VAC - 127 VAC at 5.7A
200 VAC - 240 VAC at 2.8A
Typical power consumption: 361 watts
Maximum power consumption: 500 watts
NetBackup Flex Scale requires at least four Flex Scale Appliance nodes to form a cluster. Install all the Flex Scale Appliance nodes in an EIA standard rack that is 19 inch (48.26 cm) wide and at least 39.37 inches (100 cm) deep.
Note:
1 inch = 2.54 cm
Each node is two rack units (2RU) high.
The compute node rails are extensible to 81.28mm (32in). This distance is the maximum depth that is allowed between rack posts.
Each node dimensions are as follows:
Height: 73.25 cm (28.84 in.)
Width: 44.8 cm (17.64 in.)
Depth: 8.75 cm (3.44 in.)
Weight: 37 kg (81.57 lbs)