Please enter search query.
Search <book_title>...
Veritas NetBackup™ 5230 Appliance and Storage Shelf Product Description
Last Published:
2019-10-30
Product(s):
Appliances (Version Not Specified)
Platform: Veritas 5230
- Product overview
- About the appliance
- About storage capacity
- About best practices for rack installation
- About the appliance rear panel
- About the mainboard RAID controller
- About the external RAID controller
- About the NetBackup 5230 rear panel configurations
- About the FC HBA port configurations
- About the 2-port 8 Gb FC HBA
- About the dual-port 10 Gb Ethernet card
- About the Veritas 3U16 24TB Storage Shelf / Veritas 3U16 36TB Storage Shelf
- Appliance and storage shelf connections
- NetBackup 5230 documentation
- Cables
- Technical specifications, standards, and compliance information
- Appendix A. About the optional Veritas 2U12 49TB Storage Shelf
Power Cooling Module LEDs
Power Cooling Modules (PCM) use four LEDs to indicate the status of the PCM.
Table: Power Cooling Module LED legend
Number | LED condition |
|---|---|
1 | AC fail |
2 | Fan fail |
3 | Power Cooling Module OK |
4 | DC fail |
Table: Power Cooling Module LED conditions
Status | Power Cooling Module OK (Green) | Fan Fail (Amber) | AC Fail (Amber) | DC Fail (Amber) |
|---|---|---|---|---|
No AC Power (any Power Cooling Module) | Off | Off | Off | Off |
No AC Power (this Power Cooling Module only) | Off | Off | On | On |
AC Present (Power Cooling Module On OK) | On | Off | Off | Off |
Power Cooling Module fan out of tolerance | On | Off | Off | On |
Power Cooling Module fan fail | Off | On | Off | Off |
Power Cooling Module Fault (Over temp, over volts, over current) | Off | On | On | On |
Standby Mode | Flashing | Off | Off | Off |
Power Cooling Module firmware download | Off | Flashing | Flashing | Flashing |