Dynamic Multi-Pathing 7.3.1 Administrator's Guide - AIX
- Understanding DMP
- Setting up DMP to manage native devices
- About setting up DMP to manage native devices
- Displaying the native multi-pathing configuration
- Migrating LVM volume groups to DMP
- Migrating to DMP from EMC PowerPath
- Migrating to DMP from Hitachi Data Link Manager (HDLM)
- Migrating to DMP from IBM Multipath IO (MPIO) or MPIO path control module (PCM)
- Using Dynamic Multi-Pathing (DMP) devices with Oracle Automatic Storage Management (ASM)
- Enabling Dynamic Multi-Pathing (DMP) devices for use with Oracle Automatic Storage Management (ASM)
- Removing Dynamic Multi-Pathing (DMP) devices from the listing of Oracle Automatic Storage Management (ASM) disks
- Migrating Oracle Automatic Storage Management (ASM) disk groups on operating system devices to Dynamic Multi-Pathing (DMP) devices
- Adding DMP devices to an existing LVM volume group or creating a new LVM volume group
- Removing DMP support for native devices
- Dynamic Multi-Pathing for the Virtual I/O Server
- About Dynamic Multi-Pathing in a Virtual I/O server
- About the Volume Manager (VxVM) component in a Virtual I/O server
- Configuring Dynamic Multi-Pathing (DMP) on Virtual I/O server
- Configuring Dynamic Multi-Pathing (DMP) pseudo devices as virtual SCSI devices
- Extended attributes in VIO client for a virtual SCSI disk
- Administering DMP
- About enabling and disabling I/O for controllers and storage processors
- About displaying DMP database information
- Displaying the paths to a disk
- Setting customized names for DMP nodes
- Configuring DMP for SAN booting
- Administering the root volume group (rootvg) under DMP control
- Running the bosboot command when LVM rootvg is enabled for DMP
- Extending an LVM rootvg that is enabled for DMP
- Reducing the native rootvg that is enabled for DMP
- Mirroring the root volume group
- Removing the mirror for the root volume group (rootvg)
- Cloning a LVM rootvg that is enabled for DMP
- Cleaning up the alternate disk volume group when LVM rootvg is enabled for DMP
- Using mksysb when the root volume group is under DMP control
- Upgrading Dynamic Multi-Pathing and AIX on a DMP-enabled rootvg
- Using Storage Foundation in the logical partition (LPAR) with virtual SCSI devices
- Setting up DMP for vSCSI devices in the logical partition (LPAR)
- About disabling DMP for vSCSI devices in the logical partition (LPAR)
- Preparing to install or upgrade Storage Foundation with DMP disabled for vSCSI devices in the logical partition (LPAR)
- Disabling DMP multi-pathing for vSCSI devices in the logical partition (LPAR) after installation or upgrade
- Adding and removing DMP support for vSCSI devices for an array
- How DMP handles I/O for vSCSI devices
- Running alt_disk_install, alt_disk_copy and related commands on the OS device when DMP native support is enabled
- Administering DMP using the vxdmpadm utility
- Retrieving information about a DMP node
- Displaying consolidated information about the DMP nodes
- Displaying the members of a LUN group
- Displaying paths controlled by a DMP node, controller, enclosure, or array port
- Displaying information about controllers
- Displaying information about enclosures
- Displaying information about array ports
- User-friendly CLI outputs for ALUA arrays
- Displaying information about devices controlled by third-party drivers
- Displaying extended device attributes
- Suppressing or including devices from VxVM control
- Gathering and displaying I/O statistics
- Setting the attributes of the paths to an enclosure
- Displaying the redundancy level of a device or enclosure
- Specifying the minimum number of active paths
- Displaying the I/O policy
- Specifying the I/O policy
- Disabling I/O for paths, controllers, array ports, or DMP nodes
- Enabling I/O for paths, controllers, array ports, or DMP nodes
- Renaming an enclosure
- Configuring the response to I/O failures
- Configuring the I/O throttling mechanism
- Configuring Subpaths Failover Groups (SFG)
- Configuring Low Impact Path Probing (LIPP)
- Displaying recovery option values
- Configuring DMP path restoration policies
- Stopping the DMP path restoration thread
- Displaying the status of the DMP path restoration thread
- Configuring Array Policy Modules
- Administering disks
- About disk management
- Discovering and configuring newly added disk devices
- Partial device discovery
- About discovering disks and dynamically adding disk arrays
- About third-party driver coexistence
- How to administer the Device Discovery Layer
- Listing all the devices including iSCSI
- Listing all the Host Bus Adapters including iSCSI
- Listing the ports configured on a Host Bus Adapter
- Listing the targets configured from a Host Bus Adapter or a port
- Listing the devices configured from a Host Bus Adapter and target
- Getting or setting the iSCSI operational parameters
- Listing all supported disk arrays
- Excluding support for a disk array library
- Re-including support for an excluded disk array library
- Listing excluded disk arrays
- Listing disks claimed in the DISKS category
- Displaying details about an Array Support Library
- Adding unsupported disk arrays to the DISKS category
- Removing disks from the DISKS category
- Foreign devices
- Changing the disk device naming scheme
- Discovering the association between enclosure-based disk names and OS-based disk names
- Dynamic Reconfiguration of devices
- About online Dynamic Reconfiguration
- Reconfiguring a LUN online that is under DMP control using the Dynamic Reconfiguration tool
- Manually reconfiguring a LUN online that is under DMP control
- Overview of manually reconfiguring a LUN
- Manually removing LUNs dynamically from an existing target ID
- Manually adding new LUNs dynamically to a new target ID
- About detecting target ID reuse if the operating system device tree is not cleaned up
- Scanning an operating system device tree after adding or removing LUNs
- Manually cleaning up the operating system device tree after removing LUNs
- Manually replacing a host bus adapter online
- Changing the characteristics of a LUN from the array side
- Upgrading the array controller firmware online
- Event monitoring
- Performance monitoring and tuning
- About tuning Dynamic Multi-Pathing (DMP) with templates
- DMP tuning templates
- Example DMP tuning template
- Tuning a DMP host with a configuration attribute template
- Managing the DMP configuration files
- Resetting the DMP tunable parameters and attributes to the default values
- DMP tunable parameters and attributes that are supported for templates
- DMP tunable parameters
- DMP driver tunables
- Appendix A. DMP troubleshooting
- Appendix B. Reference
Displaying paths controlled by a DMP node, controller, enclosure, or array port
The vxdmpadm getsubpaths command lists all of the paths known to Dynamic Multi-Pathing (DMP). The vxdmpadm getsubpaths command also provides options to list the subpaths through a particular DMP node, controller, enclosure, or array port. To list the paths through an array port, specify either a combination of enclosure name and array port id, or array port worldwide name (WWN).
To list all subpaths known to DMP:
# vxdmpadm getsubpaths
NAME STATE[A] PATH-TYPE[M] DMPNODENAME ENCLR-NAME CTLR ATTRS ============================================================================= hdisk1 ENABLED(A) - disk_0 disk scsi0 - hdisk0 ENABLED(A) - disk_1 disk scsi0 - hdisk107 ENABLED(A) PRIMARY emc_clariion0_17 emc_clariion0 fscsi1 - hdisk17 ENABLED SECONDARY emc_clariion0_17 emc_clariion0 fscsi0 - hdisk108 ENABLED(A) PRIMARY emc_clariion0_74 emc_clariion0 fscsi1 - hdisk18 ENABLED SECONDARY emc_clariion0_74 emc_clariion0 fscsi0 - hdisk109 ENABLED(A) PRIMARY emc_clariion0_75 emc_clariion0 fscsi1 - hdisk19 ENABLED SECONDARY emc_clariion0_75 emc_clariion0 fscsi0 -
The vxdmpadm getsubpaths command combined with the dmpnodename attribute displays all the paths to a LUN that are controlled by the specified DMP node name from the /dev/vx/rdmp directory:
# vxdmpadm getsubpaths dmpnodename=hdisk22 NAME STATE[A] PATH-TYPE[M] CTLR-NAME ENCLR-TYPE ENCLR-NAME ATTRS ==================================================================== hdisk22 ENABLED(A) PRIMARY scsi2 ACME enc0 - hdisk21 ENABLED PRIMARY scsi1 ACME enc0 -
For A/A arrays, all enabled paths that are available for I/O are shown as ENABLED(A).
For A/P arrays in which the I/O policy is set to singleactive, only one path is shown as ENABLED(A). The other paths are enabled but not available for I/O. If the I/O policy is not set to singleactive, DMP can use a group of paths (all primary or all secondary) for I/O, which are shown as ENABLED(A).
Paths that are in the DISABLED state are not available for I/O operations.
A path that was manually disabled by the system administrator displays as DISABLED(M). A path that failed displays as DISABLED.
You can use getsubpaths to obtain information about all the paths that are connected to a particular HBA controller:
# vxdmpadm getsubpaths ctlr=fscsi1 NAME STATE[A] PATH-TYPE[M] DMPNODENAME ENCLR-TYPE ENCLR-NAME ATTRS ============================================================================= hdisk107 ENABLED(A) PRIMARY emc_clariion0_17 EMC_CLARiiON emc_clariion0 - hdisk62 ENABLED SECONDARY emc_clariion0_17 EMC_CLARiiON emc_clariion0 - hdisk108 ENABLED(A) PRIMARY emc_clariion0_74 EMC_CLARiiON emc_clariion0 - hdisk63 ENABED SECONDARY emc_clariion0_74 EMC_CLARiiON emc_clariion0 -
You can also use getsubpaths to obtain information about all the paths that are connected to a port on an array. The array port can be specified by the name of the enclosure and the array port ID, or by the WWN identifier of the array port:
# vxdmpadm getsubpaths enclosure=enclosure portid=portid # vxdmpadm getsubpaths pwwn=pwwn
For example, to list subpaths through an array port through the enclosure and the array port ID:
# vxdmpadm getsubpaths enclosure=emc_clariion0 portid=A2
NAME STATE[A] PATH-TYPE[M] DMPNODENAME ENCLR-NAME CTLR ATTRS ======================================================================== hdisk111 ENABLED(A) PRIMARY emc_clariion0_80 emc_clariion0 fscsi1 - hdisk51 ENABLED(A) PRIMARY emc_clariion0_80 emc_clariion0 fscsi0 - hdisk112 ENABLED(A) PRIMARY emc_clariion0_81 emc_clariion0 fscsi1 - hdisk52 ENABLED(A) PRIMARY emc_clariion0_81 emc_clariion0 fscsi0 -
For example, to list subpaths through an array port through the WWN:
NAME STATE[A] PATH-TYPE[M] DMPNODENAME ENCLR-NAME CTLR ATTRS ======================================================================== hdisk111 ENABLED(A) PRIMARY emc_clariion0_80 emc_clariion0 fscsi1 - hdisk51 ENABLED(A) PRIMARY emc_clariion0_80 emc_clariion0 fscsi0 - hdisk112 ENABLED(A) PRIMARY emc_clariion0_81 emc_clariion0 fscsi1 - hdisk52 ENABLED(A) PRIMARY emc_clariion0_81 emc_clariion0 fscsi0 -
You can use getsubpaths to obtain information about all the subpaths of an enclosure.
# vxdmpadm getsubpaths enclosure=enclosure_name [ctlr=ctlrname]
To list all subpaths of an enclosure:
# vxdmpadm getsubpaths enclosure=emc_clariion0 NAME STATE[A] PATH-TYPE[M] DMPNODENAME ENCLR-NAME CTLR ATTRS ================================================================================ hdisk107 ENABLED(A) PRIMARY emc_clariion0_17 emc_clariion0 fscsi1 - hdisk17 ENABLED SECONDARY emc_clariion0_17 emc_clariion0 fscsi0 - hdisk110 ENABLED(A) PRIMARY emc_clariion0_76 emc_clariion0 fscsi1 - hdisk20 ENABLED SECONDARY emc_clariion0_76 emc_clariion0 fscsi0 -
To list all subpaths of a controller on an enclosure:
By default, the output of the vxdmpadm getsubpaths command is sorted by enclosure name, DMP node name, and within that, path name.
To sort the output based on the pathname, the DMP node name, the enclosure name, or the host controller name, use the -s option.
To sort subpaths information, use the following command:
# vxdmpadm -s {path | dmpnode | enclosure | ctlr} getsubpaths \
[all | ctlr=ctlr_name | dmpnodename=dmp_device_name | \
enclosure=enclr_name [ctlr=ctlr_name | portid=array_port_ID] | \
pwwn=port_WWN | tpdnodename=tpd_node_name] More Information