Veritas InfoScale™ Operations Manager 8.0.2 Add-ons User's Guide
- Section I. VCS Utilities Add-on 8.0.2
- Section II. Distribution Manager Add-on 8.0.2
- Section III. Fabric Insight Add-on 8.0.2
- Section IV. Patch Installer Add-on 1.0
- Introduction to Patch Installer Add-on
- Using Patch Installer Add-on
- Prerequisites for deploying SFHA hot fixes
- Deploying SFHA hot fixes
- Requirements for scripts to customize SFHA hot fix deployment
- Adding pre-installation and post-installation scripts to SFHA hot fixes
- Removing or replacing custom scripts for SFHA hot fixes
- Viewing information about SFHA hot fix deployment requests
- Section V. Storage Insight Add-on 8.0.2
- Performing the deep discovery of enclosures
- About Storage Insight Add-on
- About the discovery host
- About the network-attached storage discovery
- Adding HITACHI storage enclosures for deep discovery
- Adding EMC Symmetrix storage enclosures for deep discovery
- Adding IBM XIV storage enclosures for deep discovery
- Adding NetApp storage enclosures for deep discovery
- Adding EMC CLARiiON storage enclosures for deep discovery
- Adding HP EVA storage enclosures for deep discovery
- Adding IBM System Storage DS enclosures for deep discovery
- Adding EMC Celerra storage enclosures for deep discovery
- Adding EMC VNX storage enclosures for deep discovery
- Adding EMC VPLEX storage enclosures for deep discovery
- Adding 3PAR storage enclosures for deep discovery
- Adding IBM SVC storage enclosures for deep discovery
- Editing the deep discovery configuration for an enclosure
- Removing deep discovery for a storage enclosure
- Refreshing the enclosures that are configured for deep array discovery
- Monitoring the usage of thin pools
- Monitoring storage array metering data
- Managing LUN classifications
- Appendix A. Enclosure configuration prerequisites
- HITACHI enclosure configuration prerequisites
- EMC Symmetrix storage array configuration prerequisites
- Physical connection requirements for EMC Symmetrix enclosure
- Device setup requirements for EMC Symmetrix arrays
- Veritas InfoScale Operations Manager setup requirements for in-band EMC Symmetrix storage arrays
- Veritas InfoScale Operations Manager setup requirements to discover EMC Symmetrix storage arrays through remote SYMAPI servers
- IBM XIV enclosure configuration prerequisites
- NetApp storage enclosure configuration prerequisites
- EMC CLARiiON storage enclosures configuration prerequisites
- Hewlett-Packard Enterprise Virtual Array (HP EVA) configuration prerequisites
- IBM System Storage DS enclosure configuration prerequisites
- IBM SVC enclosure configuration prerequisites
- EMC Celerra enclosure configuration prerequisites
- EMC VNX storage enclosure configuration prerequisites
- EMC VPLEX storage enclosure configuration prerequisites
- 3PAR storage enclosure configuration prerequisites
- Appendix B. Commands used by Management Server for deep discovery of enclosures
- HITACHI storage enclosure commands
- EMC Symmetrix storage enclosure commands
- IBM XIV storage enclosures commands
- NetApp storage enclosure commands
- EMC CLARiiON storage enclosure commands
- HP EVA storage enclosure commands
- IBM System Storage DS enclosure commands
- EMC Celerra storage enclosure commands
- EMC VNX (Block) storage enclosure commands
- EMC VNX (File) storage enclosure commands
- EMC VPLEX storage enclosure commands
- 3PAR storage enclosure commands
- IBM SVC storage enclosure commands
- Performing the deep discovery of enclosures
- Section VI. Storage Insight SDK Add-on 8.0.2
- Overview of Storage Insight SDK Add-on 8.0.2
- Managing Veritas InfoScale Operations Manager Storage Insight plug-ins
- About creating Storage Insight plug-in
- About installing Storage Insight SDK Add-on
- About discovery script
- About the enclosure discovery command output
- --list encls command to discover all enclosures
- --list pdevs --encl enclosure Id command to discover all physical disks in an enclosure
- --list ldevs --encl enclosure Id command to discover all logical disks for an enclosure
- --list adapters --encl enclosure Id command to discover all adapters of an enclosure
- --list ports --encl enclosure Id command to discover all ports for an enclosure
- --list capacities --encl enclosure Id command to discover aggregate physical, RAID group, and logical capacities for an enclosure
- --list ldevpdevmap --encl enclosure Id command to discover logical disk-physical disk mapping for an enclosure
- --list ldevhostmap --encl enclosure Id command to discover logical device-host mapping for an enclosure
- --list meta-ldevs --encl enclosure Id command to discover the mapping of meta logical disks with segment logical disks for an enclosure
- --list raidgroups --encl enclosure Id command to discover RAID groups for an enclosure
- --list thinpools --encl enclosure Id command to discover all thin pools for an enclosure
- --list rgpdevmap --encl enclosure Id command to discover RAID group-physical disk mapping for an enclosure
- --list rgldevmap --encl enclosure Id command to discover RAID group-logical device mapping for an enclosure
- --list tpsrcldevmap --encl enclosure Id command to discover thin pool-source logical device mapping for an enclosure
- --list tpldevmap --encl enclosure Id command to discover thin pool logical device mapping for an enclosure
- --list replications --encl enclosure Id command to discover the replications for an enclosure
- About additional scripts
- About device identifiers
- Storage Insight Plug-in sample
- Creating a Storage Insight plug-in
- Editing a Storage Insight plug-in
- Testing a Storage Insight plug-in
- About creating Storage Insight plug-in
- Section VII. Storage Provisioning and Enclosure Migration Add-on 8.0.2
- Provisioning storage
- About storage provisioning
- About creating a storage template
- Creating a storage template using VxFS file systems
- Creating a storage template using NTFS file systems
- Creating a storage template using volumes
- Updating a storage template
- Provisioning storage
- Uploading storage templates
- Downloading storage templates
- Deleting storage templates
- Locking storage templates
- Unlocking storage templates
- Migrating volumes
- Provisioning storage
- Section VIII. Application Migration Add-on
- Introduction to Application Migration Add-on
- Creating and managing an application migration plan
- Supported versions and platforms
- User privileges
- Prerequisites for creating an application migration plan
- Prerequisites for migration to AWS
- VVR Replication: Environment variables used in application migration
- Creating an application migration plan
- Understanding user-defined tasks
- Understanding application migration operations
- Understanding the cleanup operation
- Understanding the tasks executed in each operation
- Validations performed before migration plan execution
- Executing the application migration plan
- Editing an application migration plan
- Deleting application migration plan(s)
- Exporting application migration plan(s)
- Importing application migration plan(s)
- Viewing historical runs
- Viewing properties of an application migration plan
- Application migration logs
- Index
VVR Replication: Environment variables used in application migration
In the source and target cluster nodes, configure every disk group that must be migrated with a Storage Replicator Log (SRL) volume. During Rehearse operation, create cache volume in every disk group on the secondary site so that space-optimized snapshots can be created. The application migration plan creates the required SRL volume and cache volume. For creating these volumes, 10% of the used size of the disk group is taken as the default size.
To override the default size of both SRL volume and cache volume, mention the size required for a disk group using specific variables in the appmig.conf file. The file is not present by default. On the node where the disk group is online, create the file in the /opt/VRTSsfmh/etc directory. In the file, define the variable for each disk group.
For example, for a set of service groups to be migrated, if one disk group is online on one node and another disk group is online on another node, create the file for each node and define the variable in the file where the corresponding disk groups are online.
Veritas recommends keeping one copy of the environment file with all necessary entries and copy the same file across all nodes in the source and target clusters.
Note:
Mention the size in megabytes.
Define the following environment variables in the file:
SRLVOL_SIZE_DiskGroup
CACHEVOL_SIZE_DiskGroup
To specify 1 GB size for SRL volume and 2 GB size for cache volume for disk group dg1, define the variables as follows:
SRLVOL_SIZE_dg1 = 1024M
CACHEVOL_SIZE_dg1 = 2048M
During plan creation from the source cluster node the file checks whether:
Sufficient space is available in the source disk group for creating SRL volume.
Sum of the size of disks selected for creating disk group in the target cluster is greater than the sum of the used space in the source disk group, plus SRL volume and cache volume size calculated by the plan.
During the Setup Storage operation, the SRL volume size is retrieved from the file in the source cluster node and the size is used to create the SRL volume for the disk group in the source and target cluster nodes.
During the Rehearse operation, the cache volume size is retrieved from the file in the target cluster node and the size is used to create the cache volume for the disk group in the target cluster node.