Please enter search query.
Search <book_title>...
Veritas InfoScale 7.0 Installation and Upgrade Guide - Windows
Last Published:
2018-09-04
Product(s):
InfoScale & Storage Foundation (7.0)
Platform: Windows
- Preinstallation and planning
- Installing the Infoscale products
- About installing Veritas InfoScale products
- About InfoScale products co-existence
- Installing the server components using the product installer
- Installing the server components using CLI
- Available product options and supported DMPW DSMs
- Registering InfoScale Storage resource DLLs
- Installing the client components
- Upgrading to InfoScale products
- Performing the post upgrade tasks
- Deployment scenarios and applicable post upgrade tasks
- Re-enabling Volume Replicator in a non-clustered environment
- Re-enabling Volume Replicator in a Windows Server Failover Cluster environment
- Reconnecting DMPW DSM paths after the upgrade
- Re-configuring the Veritas Scheduler Service
- Re-configuring the VxSAS service
- Importing the configured rules
- Upgrading the dynamic disk group version
- Reinstalling the custom agents
- Including custom resources
- Administering InfoScale product installation
- Uninstalling InfoScale products
- Performing application upgrades in an InfoScale environment
- Upgrading Microsoft SQL Server
- Upgrading SQL Server 2008 to SQL Server 2008 R2
- Preupgrade tasks for upgrading SQL Server 2008 to SQL Server 2008 R2 in a disaster recovery environment
- Upgrading SQL Server 2008 to SQL Server 2008 R2 on the first cluster node
- Upgrading SQL Server 2008 to SQL Server 2008 R2 on additional failover nodes
- Modifying the SQL Server 2008 service group configuration
- Deleting the SQL Server 2008 service group and creating the SQL Server 2008 R2 service group
- Upgrading to later versions of SQL Server
- Upgrading SQL Server 2008 to SQL Server 2008 R2
- Upgrading Oracle
- Upgrading application service packs in an InfoScale environment
- Upgrading Microsoft SQL Server
- Appendix A. Services and ports
- Appendix B. Migrating from 3rd party multi-pathing solution to Dynamic Multi-pathing
Migrating from EMC PowerPath
Migrating from EMC PowerPath involves removing the devices from EMC PowerPath (PP) control and enabling InfoScale Foundation on the devices.
The migration process requires you to:
Stop the applications
Stop VCS services, if using VCS
As a result, the migration process involves some downtime for the applications running on the systems.
To uninstall EMC PowerPath and install InfoScale Foundation, perform the following:
- Disable/disconnect all but one path from the system to the storage.
- Remove the EMC PowerPath (PP).
Refer to the EMC instructions for removing PowerPath.
- Reboot the system after the PowerPath has been removed.
- Install InfoScale Foundation.
During installation, select MPIO device-specific modules (DSMs) for the attached storage (for example, EMC CLARiiON and Hitachi AMS).
- Reboot the system.