Veritas NetBackup™ 命令参考指南
- 介绍
- 附录 A. NetBackup 命令
- acsd
- add_media_server_on_clients
- backupdbtrace
- backuptrace
- bmrc
- bmrconfig
- bmrepadm
- bmrprep
- bmrs
- bmrsrtadm
- bp
- bparchive
- bpbackup
- bpbackupdb
- bpcatarc
- bpcatlist
- bpcatres
- bpcatrm
- bpcd
- bpchangeprimary
- bpclient
- bpclimagelist
- bpclntcmd
- bpclusterutil
- bpcompatd
- bpconfig
- bpdbjobs
- bpdbm
- bpdgclone
- bpdown
- bpduplicate
- bperror
- bpexpdate
- bpfis
- bpflist
- bpgetconfig
- bpgetdebuglog
- bpimage
- bpimagelist
- bpimmedia
- bpimport
- bpinst
- bpkeyfile
- bpkeyutil
- bplabel
- bplist
- bpmedia
- bpmedialist
- bpminlicense
- bpnbat
- bpnbaz
- bppficorr
- bpplcatdrinfo
- bpplclients
- bppldelete
- bpplinclude
- bpplinfo
- bppllist
- bpplsched
- bpplschedrep
- bpplschedwin
- bppolicynew
- bpps
- bprd
- bprecover
- bprestore
- bpretlevel
- bpschedule
- bpschedulerep
- bpsetconfig
- bpstsinfo
- bpstuadd
- bpstudel
- bpstulist
- bpsturep
- bptestbpcd
- bptestnetconn
- bptpcinfo
- bpup
- bpverify
- cat_convert
- cat_export
- cat_import
- configureCertsForPlugins
- configureMQ
- configurePorts
- configureWebServerCerts
- create_nbdb
- csconfig cldinstance
- csconfig cldprovider
- csconfig meter
- csconfig throttle
- csconfig reinitialize
- duplicatetrace
- importtrace
- jbpSA
- jnbSA
- ltid
- manageClientCerts
- mklogdir
- nbauditreport
- nbcatsync
- NBCC
- NBCCR
- nbcertcmd
- nbcertupdater
- nbcldutil
- nbcloudrestore
- nbcomponentupdate
- nbcplogs
- nbdb_admin
- nbdb_backup
- nbdb_move
- nbdb_ping
- nbdb_restore
- nbdb_unload
- nbdbms_start_server
- nbdbms_start_stop
- nbdc
- nbdecommission
- nbdelete
- nbdeployutil
- nbdevconfig
- nbdevquery
- nbdiscover
- nbdna
- nbemm
- nbemmcmd
- nbfindfile
- nbfirescan
- nbftadm
- nbftconfig
- nbgetconfig
- nbhba
- nbholdutil
- nbhostidentity
- nbhostmgmt
- nbhypervtool
- nbimageshare
- nbinstallcmd
- nbjm
- nbkmsutil
- nboraadm
- nborair
- nbpem
- nbpemreq
- nbperfchk
- nbplupgrade
- nbrb
- nbrbutil
- nbregopsc
- nbreplicate
- nbrepo
- nbrestorevm
- nbseccmd
- nbsetconfig
- nbsnapimport
- nbsnapreplicate
- nbsqladm
- nbstl
- nbstlutil
- nbstop
- nbsu
- nbsvrgrp
- resilient_clients
- restoretrace
- stopltid
- tl4d
- tl8d
- tl8cd
- tldd
- tldcd
- tlhd
- tlhcd
- tlmd
- tpautoconf
- tpclean
- tpconfig
- tpext
- tpreq
- tpunmount
- verifytrace
- vltadm
- vltcontainers
- vlteject
- vltinject
- vltoffsitemedia
- vltopmenu
- vltrun
- vmadd
- vmchange
- vmcheckxxx
- vmd
- vmdelete
- vmoprcmd
- vmphyinv
- vmpool
- vmquery
- vmrule
- vmupdate
- vnetd
- vssat
- vwcp_manage
- vxlogcfg
- vxlogmgr
- vxlogview
- W2KOption
名称
bpcompatd — 运行 NetBackup 兼容性服务
大纲
[-max_time seconds] [-console] [-debug]
-alive [-debug]
-terminate [-debug]
-bpcd_connect clientname [-debug]
-bpdbm_connect hostname [-debug]
-bpjobd_connect hostname [-debug]
-bprd_connect hostname [-debug]
-robot_connect hostname robot_type [-debug]
-vmd_connect hostname [-debug]
在 UNIX 系统上,此命令的目录路径为 /usr/openv/netbackup/bin/
在 Windows 系统中,此命令的目录路径为 install_path\NetBackup\bin\
描述
新的 NetBackup 服务在内部使用此命令与旧式的 NetBackup 服务进行通信。
选项
- -alive
测试本地 bpcompatd 后台驻留程序或服务以查看其是否正在运行。
- -bpcd_connect clientname
使用 bpcompatd 命令测试与 clientname 的 bpcd 连接。
- -bpdbm_connect hostname
使用 bpcompatd 命令测试与 hostname 的 bpdbm 连接。
- -bpjobd_connect hostname
使用 bpcompatd 命令测试与 hostname 的 bpjobd 连接。
- -bprd_connect hostname
使用 bpcompatd 命令测试与 hostname 的 bprd 连接。
如果指定 -debug,则将通常记录到 bpcompatd 的调试日志文件中的信息写入标准错误。
如果未指定上述任何选项,则 bpcompatd 将作为后台驻留程序(对于 UNIX)或服务(对于 Windows)运行。当 bpcompatd 作为后台驻留程序或服务运行时,可以使用下列选项:
- -console
此选项仅适用于 Windows。通常,bpcompatd 是通过服务管理器运行的。可以使用 -console 选项从命令行运行 bpcompatd 服务。
- -debug
如果指定 -debug,则将通常记录到 bpcompatd 的调试日志文件中的信息写入标准错误。对于 Windows,此选项指的是 -console 选项。在 UNIX 系统上,此选项禁止在后台运行 bpcompatd 服务。
- -max_time seconds
bpcompatd 在执行日常任务之前等待新连接的最长时间。在 UNIX 系统上,默认值为 60 秒。在 Windows 系统中,默认值为 1 秒。
- -robot_connect hostname robot_type
对于 robot_type,使用 bpcompatd 命令测试与 hostname 的机械手后台驻留程序连接。
有效的机械手类型包括:
NONE - 非机械手
ACS - 自动盒式系统
TL4 - 4 毫米磁带库
TL8 - 8 毫米磁带库
TLD - DLT 磁带库
TLH - 1/2 英寸磁带库
TLM - 多介质磁带库
- -terminate
如果本地 bpcompatd 后台驻留程序或服务正在运行,则将其终止。
- -vmd_connect hostname
使用 bpcompatd 命令测试与 hostname 的 vmd 连接。