InfoScale™ 9.0 SmartIO for Solid-State Drives Solutions Guide - Linux
- Introducing SFHA Solutions SmartIO
- Using the SmartIO feature: use cases
- About SmartIO read caching for applications running on VxVM volumes
- About SmartIO read caching for applications running on VxFS file systems
- About SmartIO caching on SSD devices exported by FSS
- About SmartIO write-back caching for applications running on VxFS file systems- DLV 11 to 13
- About SmartIO FEL-based writeback caching for applications running on VxFS file systems- DLV 14 and later
- About multiple SmartIO cache areas for read and write-back caching on VxFS file systems
- About SmartIO caching for Oracle databases on VxFS file systems
- Prerequisites and configuration for using the SmartIO plug-in for Oracle
- Setting default SmartIO caching policies for a database running on a VxFS file system
- Setting SmartIO caching policies for database objects
- Pinning and unpinning database objects
- Enabling and disabling caching for the database
- Listing cache policy details for the database
- Listing cache statistics for the database
- About SmartIO caching for databases on VxVM volumes
- Technology Preview: Distributed SmartIO in Arctera InfoScale storage environments
- Administering SmartIO
- Creating a cache area
- Displaying information about a cache area
- Enabling or disabling caching for a data object
- Adding a device to the cache area
- Pausing caching from a volume to a cache area
- Removing a device from the cache area
- Destroying a cache area
- Setting the attributes of the VxVM cache area
- Setting or changing the caching mode for a VxFS cache area
- Flushing dirty data from a writeback cache area
- Tuning the writeback caching
- Viewing the SmartIO cache statistics
- Troubleshooting and error handling
- Appendix A. Command reference
Viewing the SmartIO cache statistics
Use the sfcache stat command to display the cache statistics for the system.
Table: Cache statistics describes the cache statistics in the output.
Table: Cache statistics
Field | Description |
|---|---|
HIT RATIO (VxVM cache) | Percentage of total I/Os that are satisfied from the cache. Displayed for reads and writes. |
ART(Hit)ms (VxVM cache) | Average response time for I/Os that are satisfied from the cache.Displayed for reads (RD) and writes (WR). |
ART(Miss)ms (VxVM cache) | Average response time for I/Os that are not satisfied from the cache. Displayed for r reads (RD) and writes (WR) . |
BYTES (VxVM cache) | Total size of I/Os for reads (RD) and writes (WR). |
NAME (VxVM cache) | Name of the cache area. |
TYPE (VxVM cache) | Whether the cache area is VxVM or VxFS. |
%CACHE (VxVM cache) | Percentage of the cache area that is currently used for data.for all data objects. |
Cache Size (VxFS cache) | Size of the cache area. |
Cache Utilization (VxFS cache) | Percentage of the cache area that is currently used for data. |
File Systems Using Cache (VxFS cache) | Number of file systems using the cache. |
Writeback Cache Use Limit (VxFS cache) | Size of the cache area that is used for writeback. You can set the size with the writeback_size attribute. If no size is set, the field displays Unlimited. |
Writeback Flush Timelag | Interval between when the data is written to the cache and when it is flushed to the disk. If the Writeback Flush Timelag is small, such as 10 seconds, then sfcache statistics will not show. Data is flushed to disk faster. In this case, you can determine the caching usage based on the WB Hit Ratio. |
Hit Ratio (VxFS cache) | Percentage of total I/Os that are satisfied from the cache. Displayed for reads and writes. |
Data Read (VxFS cache) | Data read from the cache. |
Data Written (VxFS cache) | Data written to the cache. |
Files Cached (VxFS cache) | Number of files present in the cache. |
Files Pinned (VxFS cache) | Number of pinned files in the cache. |
Data Pinned (VxFS cache) | Amount of data pinned in the cache. |
To view the cache statistics
- Use the following command:
# sfcache stat
HIT RATIO ART(Hit)ms ART(Miss)ms BYTES NAME %CACHE RD WR RD WR RD WR RD WR TYPE: VxVM sfcachearea_1 13.43 91.24 94.20 0.142 0.819 0.414 0.798 15.31g 4.21g TYPE: VxFS NAME: sfcachearea_2 Cache Size: 48.0 GB Cache Utilization: 72.2 MB ( 0.15 %) File Systems Using Cache: 1 Writeback Cache Use Limit: Unlimited Writeback Flush Timelag: 10 s Read Cache Hit Ratio Data Read Data Written Files Cached Files Pinned Data Pinned 0.00 % 0 KB 0 KB 0 0 0 KB