Veritas NetBackup™ Appliance Administrator's Guide
- Overview
- About accessing the NetBackup Appliance Web Console
- About the NetBackup Appliance Shell Menu
- About appliance console components
- Monitoring the NetBackup appliance
- About hardware monitoring and alerts
- About Symantec Data Center Security on the NetBackup appliance
- Managing a NetBackup appliance from the NetBackup Appliance Web Console
- About storage configuration
- About Copilot functionality and Share management
- About viewing storage space information using the Show command
- About appliance supported tape devices
- About configuring Host parameters for your appliance
- Manage > Appliance Restore
- Manage > License
- About the Migration Utility
- Software release updates for NetBackup Appliances
- About installing an EEB
- About installing NetBackup Administration Console and client software
- Manage > Additional Servers
- Manage > High Availability
- Managing NetBackup appliance using the NetBackup Appliance Shell Menu
- About OpenStorage plugin installation
- About mounting a remote NFS
- About running NetBackup commands from the appliance
- About NetBackup administrator capabilities
- Creating a NetBackup touch file from the NetBackup appliance
- Creating NetBackup administrator user accounts
- About NetBackup administrator capabilities
- About Auto Image Replication between appliances
- About forwarding logs to an external server
- About high availability configuration
- About the non-certified disk erasure
- Understanding the NetBackup appliance settings
- Settings > Notifications
- Settings > Network
- Settings > Network > Network Settings
- Settings > Network > Fibre Transport
- Settings > Network > Host
- Settings > Authentication
- About configuring user authentication
- About authorizing NetBackup appliance users
- Settings > Authentication > LDAP
- Settings > Authentication > Active Directory
- Settings > Authentication > Kerberos-NIS
- Settings > Authentication > User Management
- Troubleshooting
- Deduplication pool catalog backup and recovery
Installing a NetBackup appliance software update using the NetBackup Appliance Shell Menu
Use the following procedure to start the appliance upgrade.
To install a downloaded release update using the NetBackup Appliance Shell Menu
- Check to make sure that the following pre-upgrade tasks have already been performed:
All jobs have been stopped or suspended and all SLPs have been paused.
The Support > Test Software command has been run and it returned a Pass result.
All of the necessary RHEL plug-in packages have been copied into the appropriate location.
- Log in to the NetBackup Appliance Shell Menu from the IPMI console.
Note:
Veritas recommends that you log in using the shell menu from the IPMI console instead of an SSH session. The IPMI console is also known as the Veritas Remote Manager interface. For details about how to access and use the Veritas Remote Manager, refer to the following document: NetBackup Appliance Hardware Installation Guide.
- To install the software release update, run the following command:
Main_Menu > Manage > Software > Install patch_name
Where patch_name is the name of the release update to install. Make sure that this patch name is the one that you want to install.
- Monitor the preflight check and watch for any Check failed messages.
After the preflight check has finished, proceed as follows:
If no Check failed messages appear, you are prompted to continue to the next step to start the upgrade.
If any Check failed messages appear, the upgrade is not allowed. You must resolve the reported failures, then launch the upgrade script again so that the preflight check can verify that the failures have been resolved. Click on the UMI links (V-409-xxx-xxxx) for information about how to resolve the reported issues.
If any Check failed messages indicate that a RHEL version third-party plug-in was not found, you must obtain the plug-in from the appropriate vendor. Refer to the following topic for installation details:
- After all preflight check items have passed, you may need to trust the CA certificate and the host ID-based certificate to start the upgrade process.
To trust and deploy the CA certificates, do the following:
Verify the CA certificate detail and enter yes to trust the CA certificate, as follows:
To continue with the upgrade, verify the following CA certificate detail and enter "yes" to trust the CA certificate. CA Certificate Details: Subject Name : /CN=nbatd/OU=root@abc.example.com/O=vx Start Date : Jul 14 12:59:18 2017 GMT Expiry Date : Jul 09 14:14:18 2037 GMT SHA1 Fingerprint : 31:E9:97:2E:50:11:51:7C:D6:25:7F:32:86:3D: 6B:D5:33:5C:11:E2 >> Do you want to trust the CA certificate? [yes, no](yes)
If the security level of the master server is Very High, you must manually enter an authorization token to deploy the host ID-based certificate on the appliance, as follows:
>> Enter token:
Note:
If the appliance is ever factory reset or re-imaged after it has been upgraded to version 3.1, a reissue token is required for the next upgrade.
If the security level of the master server is High or Medium, the authentication token is not required. The host ID-based certificate is automatically deployed onto the appliance.
For more information about security certificates, refer to the chapter "Security certificates in NetBackup" in the NetBackup Security and Encryption Guide.
- To check the upgrade status before the AIM window appears, enter the following command:
Main_Menu > Manage > Software >UpgradeStatus
The system reboots several times during the upgrade process. After the first reboot, the NetBackup Appliance Web Console and any SSH-based connections to the server are unavailable until the reboot process has completed. This condition may last two hours or more, depending on the complexity of the appliance configuration. It is important that you do not attempt to manually reboot the appliance during this time. You can use the Veritas Remote Management interface (IPMI) to view the system status. In addition, you may view the logs under
/log
or wait for the appliance to send an email upon completion of the upgrade process.After the third reboot occurs, the AIM window appears automatically and shows the upgrade progress and the estimated remaining time.
Note:
Do not close the AIM window until after the upgrade has completed.
- If problems are detected during the post-upgrade self-test, the AIM window shows the upgrade status as Paused. Other SSH sessions and email notifications also indicate this status.
Note:
If a Paused status occurs, the AIM window on the IPMI console becomes locked and does not respond to keyboard input. Before you can clear the Paused status, you must unlock the AIM window as described below.
To clear the Paused status, perform the following tasks:
Unlock the AIM window on the IPMI console as follows:
Press the Enter key several times until the login prompt appears.
Enter the user account name and the password to log in to the IPMI console again. After logging in, the AIM window reappears and should respond to keyboard input.
Continue with the following tasks to clear the Paused status.
Press the V key to switch to the Verbose view to see the logs. If there are any Unique Message Identification (UMI) codes for the errors, search for them on the Veritas Support website to get more detailed information.
Try to fix the problem that the AIM window reports.
If you need to use the shell menu, log on to the NetBackup Appliance Shell Menu through an SSH session. When the AIM window appears, press the S key to close it.
Go back to the AIM window on the IPMI console.
If you tried fixing the problem, press the A key to attempt the self-test again. If you cannot fix the problem, contact Veritas Technical Support or press the R key to roll back the appliance to the previous software version.
Note:
A rollback occurs automatically after one hour if there is no user response on the AIM window during a pause condition.
- After the upgrade has completed, the AIM window shows a summary of the upgrade results.
After the upgrade has completed and the disk pools are back online, the appliance runs a self-diagnostic test. Refer to the following file for the test results:
/log/selftest_report_<appliance_serial>_<timedate>.txt
If SMTP is configured, an email notification that contains the self-test result is sent.
- Complete this step only if your backup environment includes SAN client computers.
The Fibre Channel (FC) ports must be re-scanned to allow any SAN client computers to reconnect to the Fibre Transport (FT) devices. The re-scan must be done from the NetBackup CLI view on the appliance.
To re-scan the FC ports:
Enter the following command to see a list of NetBackup user accounts:
Manage > NetBackupCLI > List
Log on to this appliance as one of the listed NetBackup users.
Run the following command to rescan the FC ports:
nbftconfig -rescanallclients
If any SAN clients still do not work, run the following commands on each of those clients in the order as shown:
On UNIX clients:
/usr/openv/netbackup/bin/bp.kill_all
/usr/openv/netbackup/bin/bp.start_all
On Windows clients:
<install_path>\NetBackup\bin\bpdown
<install_path>\NetBackup\bin\bpup
If any SAN clients still do not work, manually initiate a SCSI device refresh at the OS level. The refresh method depends on the operating system of the client. Once the refresh has completed, attempt the nbftconfig -rescanallclients command again.
If any SAN clients still do not work, restart those clients.
Note:
If you have SLES 10 or SLES 11 SAN clients that still do not work, Veritas recommends upgrading the QLogic driver on those clients. For the affected SLES 10 clients, upgrade to version 8.04.00.06.10.3-K. For the affected SLES 11 clients, upgrade to version 8.04.00.06.11.1.