Veritas NetBackup™ Replication Director Solutions Guide
- Introduction
- Additional configuration topics
- Creating a NetBackup storage server for snapshot replication
- Configuring disk pools for snapshot and replication
- About disk pools for snapshots and snapshot replication
- Using bpstsinfo to view the replication topology of a device
- Configuring storage units and storage unit groups for snapshots and snapshot replication
- Configuring storage lifecycle policies for snapshots and snapshot replication
- Operation types in a storage lifecycle policy
- Snapshot operation in an SLP
- Index From Snapshot operation in an SLP
- Snapshot operation in an SLP
- Retention types for storage lifecycle policy operations
- Configuring backup policies for snapshots and snapshot replication
- About NDMP support for Replication Director
- Restoring from a snapshot
- About restores from array-based snapshots of virtual machines
- OpsCenter reporting
- Using NetApp disk arrays with Replication Director
- Supported NetApp topologies
- Using NetApp Data ONTAP 7-mode with Replication Director
- About using NetApp SAN-connected storage with Replication Director
- Using NetApp Clustered Data ONTAP with Replication Director
- Using Oracle with Replication Director
- Using Virtual Machines with Replication Director
- Terminology
Configuring an alert for OpenStorage events
The administrator can configure OpsCenter to send alerts based on events on OpenStorage devices (storage servers):
The storage server can generate threshold or Volume Almost Full alarms.
Alerts based on the auto-discovery of unprotected NAS file services data.
The alert policy can consider the following information before OpsCenter sends an alert:
Whether the event is considered to be an error, an informational notification, or a warning; or to consider all events regardless of classification. For example, send alerts only when the storage server generates a warning.
Whether the event contains specific words or if it is generated by a specific vendor. For example, send alerts that are generated only from the NetApp device of label xyz.
Whether the event is from a specific master server; or to consider events from all master servers.
When alerts occur, they are sent at a specified severity level to multiple email addresses. When the alerts are cleared, the same email addresses are notified. The severity level for the clearing alerts can also be specified.
See the Veritas OpsCenter Administrator's Guide for information about configuring alerts.