Veritas InfoScale 7.3.1 Release Notes - Windows
- Release notes for Veritas InfoScale
- Limitations
- Deployment limitations
- Cluster management limitations
- Storage management limitations
- Multi-pathing limitations
- Replication limitations
- Solution configuration limitations
- Internationalization and localization limitations
- Interoperability limitations
- Known issues
- Deployment issues
- Cluster management issues
- Cluster Server (VCS) issues
- Cluster Manager (Java Console) issues
- Global service group issues
- VMware virtual environment-related issues
- Cluster Server (VCS) issues
- Storage management issues
- Storage Foundation
- VEA console issues
- Snapshot and restore issues
- Snapshot scheduling issues
- Storage Foundation
- Multi-pathing issues
- Replication issues
- Solution configuration issues
- Disaster recovery (DR) configuration issues
- Fire drill (FD) configuration issues
- Quick recovery (QR) configuration issues
- Internationalization and localization issues
- Interoperability issues
- Miscellaneous issues
- Fibre Channel adapter issues
- Deployment issues
The Disaster Recovery Configuration Wizard or the Fire Drill Wizard cannot proceed when configuring an application in an EMC SRDF replication environment
When configuring an application for disaster recovery (DR) or for fire drill (FD) in an EMC SRDF replication environment, the wizard might encounter an issue and fail to proceed. (3412223, 3384096)
The wizard might display the following error:
V-52410-49479-116 0 Failed to discover 'SRDF' on node 'clusterNodeName'
This issue occurs when the wizard is unable to parse a SYMCLI output (XML file) that describes the replication configuration.
Workaround: To resolve this issue, ensure that the replication array is configured correctly.
Then, run the following EMC Symmetrix command on the system where you want to configure the application for DR or FD:
symrdf list -v pd -output xml >> XMLFilePath
If the generated XML is valid, it indicates that the array is configured correctly. Launch the wizard again to configure DR or FD.
If the generated XML is invalid or if you still encounter this error when running the wizard, you might want to configure DR or FD manually.