Please enter search query.
Search <book_title>...
Veritas InfoScale 7.3.1 Release Notes - Windows
Last Published:
2017-12-15
Product(s):
InfoScale & Storage Foundation (7.3.1)
- Release notes for Veritas InfoScale
- Limitations
- Deployment limitations
- Cluster management limitations
- Storage management limitations
- Multi-pathing limitations
- Replication limitations
- Solution configuration limitations
- Internationalization and localization limitations
- Interoperability limitations
- Known issues
- Deployment issues
- Cluster management issues
- Cluster Server (VCS) issues
- Cluster Manager (Java Console) issues
- Global service group issues
- VMware virtual environment-related issues
- Cluster Server (VCS) issues
- Storage management issues
- Storage Foundation
- VEA console issues
- Snapshot and restore issues
- Snapshot scheduling issues
- Storage Foundation
- Multi-pathing issues
- Replication issues
- Solution configuration issues
- Disaster recovery (DR) configuration issues
- Fire drill (FD) configuration issues
- Quick recovery (QR) configuration issues
- Internationalization and localization issues
- Interoperability issues
- Miscellaneous issues
- Fibre Channel adapter issues
- Deployment issues
Some Volume Replicator operations may fail to complete in a cluster environment
If an RVG is a part of a VCS cluster and the cluster resource for this RVG exists, then Volume Replicator fails the Delete RDS, Delete Secondary RVG, Delete Primary RVG, Disable Data Access, Migrate, or Make Secondary operations with the following error:
Cannot complete operation. Remote node closed connection.
This is a timing issue. The Volume Replicator VRAS module times out before completing the check to determine if the RVGs participating in the operation already have a resource created. (309295, 2603103)
Workaround: To prevent the timeout, make the following change on all cluster nodes of the Primary and Secondary cluster:
To change the timeout value
- Open the Registry Editor, and then navigate to the following location:
HKEY_LOCAL_MACHINE\SOFTWARE\VERITAS\VxSvc\CurrentVersion\VolumeManager\constants
- Modify the registry DWORD value for the AE_TIMEOUT entry, from the default value of 30 seconds to 60 seconds or higher.
- In order for the registry key change to take effect, run the following:
vxassist refresh