Veritas NetBackup™ Appliance Upgrade Guide

Last Published:
Product(s): Appliances (3.1.2)
Platform: NetBackup Appliance OS

About NetBackup Appliance firmware updates

Starting with NetBackup Appliance release 3.1.2, you can update the following appliance firmware components:

  • BIOS

  • HDD

  • JBOD

  • NIC

Updating the firmware components can be done from the NetBackup Appliance Shell Menu with the following command:

Manage > Software > Firmware > Update

This command verifies the appliance model number and then builds a list of the components that require a firmware update. You are prompted to confirm the update operation for each hardware component. If you respond with no to any prompt, a warning appears to alert you to any potential conflict.

Deployment of firmware updates

The firmware update files must reside on the appliance before you can deploy them. The following describes the supported deployment methods:

Table: Firmware update deployment

Method

Description

New installation (ISO)

Starting with version 3.1.2, firmware updates are included. After the appliance has been configured, you can run the Manage > Software > Firmware > Update command to update the components.

Upgrade (RPM)

Starting with version 3.1.2, firmware updates are included. After the appliance software has been upgraded, you can run the Manage > Software > Firmware > Update command to update the components.

EEB