InfoScale™ 9.0 Dynamic Multi-Pathing Administrator's Guide - Solaris
Last Published:
2025-09-09
Product(s):
InfoScale & Storage Foundation (9.0)
Platform: Solaris
- Understanding DMP
- About Dynamic Multi-Pathing (DMP)
- How DMP works
- Multi-controller ALUA support
- Multiple paths to disk arrays
- Device discovery
- Disk devices
- Disk device naming in DMP
- Setting up DMP to manage native devices
- About setting up DMP to manage native devices
- Displaying the native multi-pathing configuration
- Migrating ZFS pools to DMP
- Migrating to DMP from EMC PowerPath
- Migrating to DMP from Hitachi Data Link Manager (HDLM)
- Migrating to DMP from Solaris Multiplexed I/O (MPxIO)
- Using Dynamic Multi-Pathing (DMP) devices with Oracle Automatic Storage Management (ASM)
- Enabling Dynamic Multi-Pathing (DMP) devices for use with Oracle Automatic Storage Management (ASM)
- Removing Dynamic Multi-Pathing (DMP) devices from the listing of Oracle Automatic Storage Management (ASM) disks
- Migrating Oracle Automatic Storage Management (ASM) disk groups on operating system devices to Dynamic Multi-Pathing (DMP) devices
- Enabling and disabling DMP support for the ZFS root pool
- Adding DMP devices to an existing ZFS pool or creating a new ZFS pool
- Removing DMP support for native devices
- Administering DMP
- About enabling and disabling I/O for controllers and storage processors
- About displaying DMP database information
- Displaying the paths to a disk
- Setting customized names for DMP nodes
- Managing DMP devices for the ZFS root pool
- Administering DMP using the vxdmpadm utility
- Retrieving information about a DMP node
- Displaying consolidated information about the DMP nodes
- Displaying the members of a LUN group
- Displaying paths controlled by a DMP node, controller, enclosure, or array port
- Displaying information about controllers
- Displaying information about enclosures
- Displaying information about array ports
- User-friendly CLI outputs for ALUA arrays
- Displaying information about devices controlled by third-party drivers
- Displaying extended device attributes
- Suppressing or including devices from VxVM control
- Gathering and displaying I/O statistics
- Setting the attributes of the paths to an enclosure
- Displaying the redundancy level of a device or enclosure
- Specifying the minimum number of active paths
- Displaying the I/O policy
- Specifying the I/O policy
- Disabling I/O for paths, controllers, array ports, or DMP nodes
- Enabling I/O for paths, controllers, array ports, or DMP nodes
- Renaming an enclosure
- Configuring the response to I/O failures
- Configuring the I/O throttling mechanism
- Configuring Subpaths Failover Groups (SFG)
- Configuring Low Impact Path Probing (LIPP)
- Displaying recovery option values
- Configuring DMP path restoration policies
- Stopping the DMP path restoration thread
- Displaying the status of the DMP path restoration thread
- Configuring Array Policy Modules
- Configuring latency threshold tunable for metro/geo array
- Administering disks
- About disk management
- Discovering and configuring newly added disk devices
- Partial device discovery
- About discovering disks and dynamically adding disk arrays
- About third-party driver coexistence
- How to administer the Device Discovery Layer
- Listing all the devices including iSCSI
- Listing all the Host Bus Adapters including iSCSI
- Listing the ports configured on a Host Bus Adapter
- Listing the targets configured from a Host Bus Adapter or a port
- Listing the devices configured from a Host Bus Adapter and target
- Getting or setting the iSCSI operational parameters
- Listing all supported disk arrays
- Excluding support for a disk array library
- Re-including support for an excluded disk array library
- Listing excluded disk arrays
- Listing disks claimed in the DISKS category
- Displaying details about an Array Support Library
- Adding unsupported disk arrays to the DISKS category
- Removing disks from the DISKS category
- Foreign devices
- VxVM coexistence with ZFS
- Changing the disk device naming scheme
- Discovering the association between enclosure-based disk names and OS-based disk names
- Dynamic Reconfiguration of devices
- About online Dynamic Reconfiguration
- About the DMPDR utility
- Reconfiguring a LUN online that is under DMP control using the Dynamic Reconfiguration tool
- Manually reconfiguring a LUN online that is under DMP control
- Overview of manually reconfiguring a LUN
- Manually removing LUNs dynamically from an existing target ID
- Manually adding new LUNs dynamically to a new target ID
- About detecting target ID reuse if the operating system device tree is not cleaned up
- Scanning an operating system device tree after adding or removing LUNs
- Manually cleaning up the operating system device tree after removing LUNs
- Manually replacing a host bus adapter on an M5000 server
- Changing the characteristics of a LUN from the array side
- Upgrading the array controller firmware online
- Event monitoring
- About the Dynamic Multi-Pathing (DMP) event source daemon (vxesd)
- Fabric Monitoring and proactive error detection
- Dynamic Multi-Pathing (DMP) automated device discovery
- Dynamic Multi-Pathing (DMP) discovery of iSCSI and SAN Fibre Channel topology
- DMP event logging
- Starting and stopping the Dynamic Multi-Pathing (DMP) event source daemon
- Performance monitoring and tuning
- About tuning Dynamic Multi-Pathing (DMP) with templates
- DMP tuning templates
- Example DMP tuning template
- Tuning a DMP host with a configuration attribute template
- Managing the DMP configuration files
- Resetting the DMP tunable parameters and attributes to the default values
- DMP tunable parameters and attributes that are supported for templates
- DMP tunable parameters
- Appendix A. DMP troubleshooting
- Appendix B. Reference
Updating the boot device settings
For the system to be bootable with the mirror disk, update the eeprom variable boot-device with the paths of the mirrored DMP device.
The boot-device variable has a string limit. To add multiple physical path names without exceeding the string limit, use aliases for the physical paths.
To configure a mirror for the ZFS root pool using a DMP device.
- Display the subpaths of the DMP device.
# vxdmpadm getsubpaths dmpnodename=hitachi_vsp0_00f3
NAME STATE[A] PATH-TYPE[M] CTLR-NAME ENCLR-TYPE ENCLR-NAME ATTRS ======================================================================================== c3t50060E8006D43C20d3s2 ENABLED(A) - c3 Hitachi_VSP hitachi_vsp0 - c3t50060E8006D43C30d3s2 ENABLED(A) - c3 Hitachi_VSP hitachi_vsp0 - c4t50060E8006D43C20d3s2 ENABLED(A) - c4 Hitachi_VSP hitachi_vsp0 - c4t50060E8006D43C30d3s2 ENABLED(A) - c4 Hitachi_VSP hitachi_vsp0 -
- Obtain the physical path of each of the active enabled paths in step 1.
# readlink /dev/dsk/c3t50060E8006D43C20d3s0 ../../devices/pci@780/SUNW,qlc@0/fp@0,0/ssd@w5006016141e048ee,2:a
- Display the settings for the boot-device variable. The command shows the physical path for the existing boot device.
# eeprom boot-device boot-device=/pci@780/SUNW,qlc@0/fp@0,0/ssd@w5006016941e048ee,4:a
- To ensure that the eeprom boot-device settings are persistent, disable the ldmd services before changing the settings.
# svcs disable svc:/ldoms/ldmd:default
- Make sure that the attribute use-nvramrc? is set to true.
# eeprom use-nvramrc? use-nvramrc?=true
- Create aliases for the physical paths using the devalias command. The following command shows creation of aliases vxdmp1 and vxdmp2 for two paths of root disk:
# eeprom "nvramrc=devalias vxdmp1 /pci@780/SUNW,qlc@0/fp@0,0/disk@w5006016941e048ee,4:a \ vxdmp2 /pci@780/SUNW,qlc@0/fp@0,0/disk@w5006016141e048ee,2:a"
- Add the device alias for each physical path to the boot device, to enable booting from the path.
# eeprom "boot-device=vxdmp1 vxdmp2"
- Verify that the paths are added to the boot-device variable.
# eeprom boot-device boot-device=vxdmp1 vxdmp2
- Enable the ldmd services as follows:
# svcs enable svc:/ldoms/ldmd:default