Please enter search query.
Search <book_title>...
InfoScale™ 9.0 Troubleshooting Guide - AIX
Last Published:
2025-07-24
Product(s):
InfoScale & Storage Foundation (9.0)
Platform: AIX
- Introduction
- Section I. Troubleshooting VxFS configurations
- Section II. Troubleshooting VxVM configurations
- Recovering from hardware failure
- Failures on RAID-5 volumes
- Recovery from failure of a DCO volume
- Recovering from instant snapshot failure
- Recovering from failed vxresize operation
- Recovering from boot disk failure
- Managing commands, tasks, and transactions
- Backing up and restoring disk group configurations
- Troubleshooting issues with importing disk groups
- Recovering from CDS errors
- Logging and error messages
- Troubleshooting VVR configurations
- Recovery from configuration errors
- Errors during an RLINK attach
- Errors during modification of an RVG
- Recovery on the Primary or Secondary
- Recovering from Primary data volume error
- Primary SRL volume error cleanup and restart
- Primary SRL header error cleanup and recovery
- Secondary data volume error cleanup and recovery
- Recovering from hardware failure
- Section III. Troubleshooting DMP configurations
- Section IV. Troubleshooting SFCFSHA configurations
- Troubleshooting Storage Foundation Cluster File System High Availability
- Troubleshooting CFS
- Troubleshooting fenced configurations
- Troubleshooting Cluster Volume Manager in Arctera InfoScale products clusters
- Troubleshooting Storage Foundation Cluster File System High Availability
- Section V. Troubleshooting VCS configurations
- Troubleshooting and recovery for VCS
- VCS message logging
- Gathering VCS information for support analysis
- Troubleshooting the VCS engine
- Troubleshooting Low Latency Transport (LLT)
- Troubleshooting Group Membership Services/Atomic Broadcast (GAB)
- Troubleshooting VCS startup
- Troubleshooting service groups
- Troubleshooting resources
- Troubleshooting I/O fencing
- System panics to prevent potential data corruption
- Fencing startup reports preexisting split-brain
- Troubleshooting CP server
- Troubleshooting server-based fencing on the Arctera InfoScale products cluster nodes
- Issues during online migration of coordination points
- Troubleshooting notification
- Troubleshooting and recovery for global clusters
- Troubleshooting licensing
- Licensing error messages
- VCS message logging
- Troubleshooting and recovery for VCS
- Section VI. Troubleshooting SFDB configurations
Finding UMI descriptions and solutions on SORT
The SORT portal provides descriptions and solutions for InfoScale UMIs.
To find a UMI description and solution
- Access the following URL in a browser:
- In the Search field on the top right corner of any SORT page, enter the UMI code, and then click the Search icon.
- On the Search result page, click the link to your message code.
The Error Code Details page for the UMI code appears, which provides the description and any possible solutions.
(Optional) If you have a large number of search results, use the Category check boxes on the left of the page to display only error codes to find your code more easily.
- If the information on the page does not provide an adequate solution to your issue, you can click the appropriate link on the page to take one of the following actions:
Comment on the UMI or its solution.
Request a solution.
Add a solution of your own.