NetBackup™ 命令参考指南

Last Published:
Product(s): NetBackup (10.3)
  1. 介绍
    1.  
      关于 NetBackup 命令
    2.  
      浏览多个菜单级别
    3.  
      NetBackup 命令约定
    4.  
      NetBackup 介质管理器命令说明
    5.  
      IPv6 更新
  2. 附录 A. NetBackup 命令
    1.  
      acsd
    2.  
      backupdbtrace
    3.  
      backuptrace
    4.  
      bmrc
    5.  
      bmrconfig
    6.  
      bmrepadm
    7.  
      bmrprep
    8.  
      bmrs
    9.  
      bmrsrtadm
    10.  
      bp
    11.  
      bparchive
    12.  
      bpbackup
    13.  
      bpbackupdb
    14.  
      bpcatarc
    15.  
      bpcatlist
    16.  
      bpcatres
    17.  
      bpcatrm
    18.  
      bpcd
    19.  
      bpchangeprimary
    20.  
      bpcleanrestore
    21.  
      bpclient
    22.  
      bpclimagelist
    23.  
      bpclntcmd
    24.  
      bpclusterutil
    25.  
      bpcompatd
    26.  
      bpconfig
    27.  
      bpdbjobs
    28.  
      bpdbm
    29.  
      bpdgclone
    30.  
      bpdown
    31.  
      bpduplicate
    32.  
      bperror
    33.  
      bpexpdate
    34.  
      bpfis
    35.  
      bpflist
    36.  
      bpgetconfig
    37.  
      bpgetdebuglog
    38.  
      bpimage
    39.  
      bpimagelist
    40.  
      bpimmedia
    41.  
      bpimport
    42.  
      bpinst
    43.  
      bpkeyfile
    44.  
      bpkeyutil
    45.  
      bplabel
    46.  
      bplist
    47.  
      bpmedia
    48.  
      bpmedialist
    49.  
      bpminlicense
    50.  
      bpnbat
    51.  
      bpnbaz
    52.  
      bppficorr
    53.  
      bpplcatdrinfo
    54.  
      bpplclients
    55.  
      bppldelete
    56.  
      bpplinclude
    57.  
      bpplinfo
    58.  
      bppllist
    59.  
      bpplsched
    60.  
      bpplschedrep
    61.  
      bpplschedwin
    62.  
      bppolicynew
    63.  
      bpps
    64.  
      bprd
    65.  
      bprecover
    66.  
      bprestore
    67.  
      bpretlevel
    68.  
      bpschedule
    69.  
      bpschedulerep
    70.  
      bpsetconfig
    71.  
      bpstsinfo
    72.  
      bpstuadd
    73.  
      bpstudel
    74.  
      bpstulist
    75.  
      bpsturep
    76.  
      bptestbpcd
    77.  
      bptestnetconn
    78.  
      bpup
    79.  
      bpverify
    80.  
      cat_convert
    81.  
      cat_export
    82.  
      cat_import
    83.  
      configureCerts
    84.  
      configureMQ
    85.  
      configureWebServerCerts
    86.  
      create_nbdb
    87.  
      csconfig cldinstance
    88.  
      csconfig cldprovider
    89.  
      csconfig meter
    90.  
      csconfig reinitialize
    91.  
      csconfig throttle
    92.  
      duplicatetrace
    93.  
      importtrace
    94.  
      jbpSA
    95.  
      jnbSA
    96.  
      ltid
    97.  
      mklogdir
    98.  
      msdpcldutil
    99.  
      nbauditreport
    100.  
      nbcallhomeproxyconfig
    101.  
      nbcatsync
    102.  
      NBCC
    103.  
      NBCCR
    104.  
      nbcertcmd
    105.  
      nbcertupdater
    106.  
      nbcldutil
    107.  
      nbcmdrun
    108.  
      nbcomponentupdate
    109.  
      nbcplogs
    110.  
      nbcredkeyutil
    111.  
      nbdb_admin
    112.  
      nbdb_backup
    113.  
      nbdb_move
    114.  
      nbdb_ping
    115.  
      nbdb_restore
    116.  
      nbdb_unload
    117.  
      nbdb2adutl
    118.  
      nbdbms_start_server
    119.  
      nbdbms_start_stop
    120.  
      nbdc
    121.  
      nbdecommission
    122.  
      nbdelete
    123.  
      nbdeployutil
    124.  
      nbdevconfig
    125.  
      nbdevquery
    126.  
      nbdiscover
    127.  
      nbdna
    128.  
      nbemm
    129.  
      nbemmcmd
    130.  
      nbfindfile
    131.  
      nbfirescan
    132.  
      nbfp
    133.  
      nbftadm
    134.  
      nbftconfig
    135.  
      nbgetconfig
    136.  
      nbhba
    137.  
      nbholdutil
    138.  
      nbhostidentity
    139.  
      nbhostmgmt
    140.  
      nbhypervtool
    141.  
      nbidpcmd
    142.  
      nbimageshare
    143.  
      nbinstallcmd
    144.  
      nbjm
    145.  
      nbkmiputil
    146.  
      nbkmscmd
    147.  
      nbkmsutil
    148.  
      nboraadm
    149.  
      nborair
    150.  
      nbpem
    151.  
      nbpemreq
    152.  
      nbmariadb
    153.  
      nbmlb
    154.  
      nbperfchk
    155.  
      nbplupgrade
    156.  
      nbrb
    157.  
      nbrbutil
    158.  
      nbreplicate
    159.  
      nbrepo
    160.  
      nbrestorevm
    161.  
      nbseccmd
    162.  
      nbserviceusercmd
    163.  
      nbsetconfig
    164.  
      nbshvault
    165.  
      nbsmartdiag
    166.  
      nbsnapimport
    167.  
      nbsnapreplicate
    168.  
      nbsqladm
    169.  
      nbsqlite
    170.  
      nbstl
    171.  
      nbstlutil
    172.  
      nbstop
    173.  
      nbsu
    174.  
      nbsvrgrp
    175.  
      netbackup_deployment_insights
    176.  
      resilient_clients
    177.  
      restoretrace
    178.  
      stopltid
    179.  
      tldd
    180.  
      tldcd
    181.  
      tpautoconf
    182.  
      tpclean
    183.  
      tpconfig
    184.  
      tpext
    185.  
      tpreq
    186.  
      tpunmount
    187.  
      verifytrace
    188.  
      vltadm
    189.  
      vltcontainers
    190.  
      vlteject
    191.  
      vltinject
    192.  
      vltoffsitemedia
    193.  
      vltopmenu
    194.  
      vltrun
    195.  
      vmadd
    196.  
      vmchange
    197.  
      vmcheckxxx
    198.  
      vmd
    199.  
      vmdelete
    200.  
      vmoprcmd
    201.  
      vmphyinv
    202.  
      vmpool
    203.  
      vmquery
    204.  
      vmrule
    205.  
      vmupdate
    206.  
      vnetd
    207.  
      vssat
    208.  
      vwcp_manage
    209.  
      vxlogcfg
    210.  
      vxlogmgr
    211.  
      vxlogview
    212.  
      W2KOption

名称

vmphyinv — 清点磁带库或独立驱动器的介质内容并更新卷数据库

大纲

vmphyinv -rn robot_number] [-rh robot_control_host] [-h device_host][-pn pool_name] [-v volume_group] [-rc1 robot_coord1 -number number] [-drv_cnt count] [-non_interactive] [-mount_timeout timeout] [-priority number] [-verbose]

vmphyinv -rn robot_number] [-rh robot_control_host] [-h device_host] -ml media_id:media_id:...:media_id [-drv_cnt count] [-non_interactive] [-mount_timeout timeout] [-priority number] [-verbose]

vmphyinv -rn robot_number] [-rh robot_control_host] [-h device_host] [ { { [-slot_range from to] [-slot_list s1:s2:...:sN] } -d density } { { [-slot_range from to] [-slot_list s1:s2:...:sN] } -d density } ] [-drv_cnt count] [-non_interactive] [-mount_timeout timeout] [-priority number] [-verbose]

vmphyinv {-u drive_number | -n drive_name} [-h device_host] [-non_interactive] [-mount_timeout timeout] [-verbose]

 

On UNIX systems, the directory path to this command is /usr/openv/volmgr/bin/

On Windows systems, the directory path to this command is install_path\Volmgr\bin\

描述

物理清点磁带库或独立驱动器的介质内容并更新 EMM 数据库。根据磁带头中的信息,vmphyinv 装入搜索条件所指定的每个介质,读取磁带头,并更新 EMM 数据库。

有关此命令的更多信息,请参考 NetBackup 管理指南,第 I 卷

任何得到授权的用户均可运行此命令。

有关 NetBackup 授权的更多信息,请参考 NetBackup 安全和加密指南

选项

-rn robot_number

指定要清点其介质的介质管理器机械手编号。robot_number 应为已配置了驱动器的机械手。vmphyinv 将清点每个介质。它在 robot_number 的卷数据库中具有 robot_number。

-rh robot_host

指定控制机械手的主机的名称。如果没有指定主机,则采用执行此命令时所在的主机。

-h device_host

指定设备主机名。此选项用于获取企业介质管理器服务器名。如果没有指定,则使用当前主机来获取 EMM 服务器名。

-pn pool_name

指定需要清点的卷(对应于 -rn 选项所指定的机械手)的池名称,该名称区分大小写。仅当指定了 -rn 选项时才有效。

-priority number

为清点作业指定一个新优先级,该优先级将覆盖默认作业优先级。

-v volume_group

指定需要清点的卷(对应于 -rn 选项所指定的机械手)的卷组。仅当指定了 -rn 选项时才有效。

-rc1 robot_coord1

指定需要清点的介质的起始插槽。仅当指定了 -rn 选项时才有效。

-number number

指定需要清点的插槽数(从 robot_coord1 开始)。仅当同时指定了 -rn 和 -rc1 时才有效。

-ml media_id1:media_id2: ... :media_id

指定需要清点的介质的列表。仅当指定了 -rn 选项时才有效。如果指定的介质 ID 不属于指定的机械手,则跳过该介质。

-slot_range from to

指定需要清点的插槽的范围。如果一个或多个插槽为空,则跳过这些插槽。

-slot_list s1:s2:...sN

指定需要清点的插槽的列表。如果一个或多个插槽为空,则跳过这些插槽。

-d density

指定介质的密度。用户必须指定介质密度并按插槽范围或插槽列表清点介质。

-u drive_number

指定需要清点的驱动器索引。该驱动器必须包含介质并且已准备就绪。可以从管理控制台的“介质和设备管理”中获得该驱动器的编号。

-n drive_name

指定需要清点的驱动器名称。该驱动器必须包含介质并且已准备就绪。可以从管理控制台的“介质和设备管理”中获得该驱动器的名称。

-non_interactive

在默认情况下,vmphyinv 先显示一个建议列表并请求确认,然后再修改卷数据库和 EMM 数据库(如果需要)。如果指定了此选项,则无需任何确认,即可应用更改。

-mount_timeout timeout

指定装入超时时间(以秒为单位)。如果无法在指定的时间内装入介质,装入请求将被取消。默认值是 15 分钟。

-drv_cnt count

指定 vmphyinv 最多可以同时使用的驱动器数。配置的驱动器总数和此值决定了 vmphyinv 使用的驱动器的实际数目。vmphyinv 使用的驱动器数是指定的驱动器数和配置的驱动器总数两者中的最小值。默认为使用所有驱动器。

-verbose

选择详细模式。指定此选项时,将出现更多信息。例如,此信息包含以下内容: 在每个磁带上发现的可用驱动器数目以及目录库标识(如果该介质为目录库)。

示例

示例 1 - 更新连接到主机 shark 的机械手 1 的 EMM 数据库:

# vmphyinv -rn 1 -rh shark

示例 2 - 更新连接到主机 whale 的机械手 7 的 EMM 数据库。仅清点属于名称为 some_pool 的池的介质:

# vmphyinv -rn 7 -rh whale -pn some_pool

示例 3 - 更新连接到主机 dolphin 的机械手 3 的 EMM 数据库。仅清点介质 A00001、A00002 和 A00003。

# vmphyinv -rn 3 -rh dolphin -ml A00001:A00002:A00003

示例 4 - 更新连接到主机 phantom 的机械手 2(类型为 TLD)的 EMM 数据库。仅清点插槽 3 到 8 中的介质。

# vmphyinv -rn 2 -rh phantom -slot_range 3 8 -d dlt

示例 5 - 更新挂接到主机 tigerfish 上的独立驱动器(驱动器索引 3)的 EMM 数据库:

# vmphyinv -u 0 -h tigerfish

另请参见

请参见vmupdate(1m)。

请参见vmcheckxxx(1m)。

请参见vmoprcmd(1m)。