NetBackup™ Snapshot Client Administrator's Guide
- Introduction
- Installation
- Policy configuration
- Notes on policies
- Configuring a policy
- Backup Selections tab options when configuring a policy
- Off-host backup configuration options
- Selecting the snapshot method
- Configuring backup scripts
- About using alternate client backup
- Configuring alternate client backup
- Policy configuration tips
- About disabling snapshots
- NAS snapshot configuration
- About NAS snapshot overview
- Dynamic data streaming for D-NAS workloads
- Prerequisites for NetBackup DNAS configuration
- Configuring dynamic data streaming with backup host pool
- Configuring a backup host pool
- Discover plugins
- Minimum supported backup host versions for different features
- Limitations and considerations
- Setting up a NAS-Data-Protection policy
- FlashBackup configuration
- Instant Recovery configuration
- About Instant Recovery capabilities
- Instant Recovery requirements
- Instant Recovery restrictions
- Giving full server privileges to the media server
- About Instant Recovery
- Configuring a policy for Instant Recovery
- About sizing the cache for Instant Recovery copy-on-write snapshots
- Instant Recovery for databases
- About storage lifecycle policies for snapshots
- Configuration of software-based snapshot methods
- Support for Cluster Volume Manager Environments (CVM)
- Configuration of snapshot methods for disk arrays
- OS-specific configuration tasks
- About IBM DS6000 and DS8000 arrays
- IBM DS6000 and DS8000 software requirements
- Preconfiguration for IBM arrays
- Configuring NetBackup to access the IBM DS6000 or DS8000 array
- Configuring the IBM array for NetBackup
- Using DSCLI commands to obtain unique IBM identifiers
- Configuring a NetBackup policy for IBM_DiskStorage_FlashCopy
- For further reference on IBM arrays
- About IBM DS4000 array
- About Hitachi SMS/WMS/AMS, USP/NSC, USP-V/VM
- Hitachi array software requirements
- Preconfiguration for Hitachi
- About communication between NetBackup and the Hitachi array
- Determining if the Hitachi command devices are visible
- About configuring the Hitachi array for NetBackup
- Obtaining the Hitachi array serial number and the unique device identifiers
- Configuring a NetBackup policy for Hitachi_ShadowImage or Hitachi_CopyOnWrite
- About HP-XP arrays
- HP-XP array software requirements
- Preconfiguration for HP-XP
- About communication between NetBackup and the HP-XP array
- Determining if the HP-XP command devices are visible
- About configuring the HP-XP array for NetBackup
- Obtaining the array serial number and unique HP-XP identifiers
- Configuring a NetBackup policy for HP_XP_BusinessCopy and HP_XP_Snapshot
- About array troubleshooting
- Notes on Media Server and Third-Party Copy methods
- Disk requirements for Media Server and Third-Party Copy methods
- Directives for Media Server and Third-Party Copy methods
- Storage units for Media Server and Third-Party Copy methods
- Preventing multiplexing on a third-party copy backup
- Raw partition backups
- Increasing the client read timeout for all clients
- Further information on off-host data mover backups
- Backup and restore procedures
- Snapshot management
- Troubleshooting
- About gathering information and checking logs
- Logging directories for UNIX platforms
- Logging folders for Windows platforms
- Customer support contact information
- Latest patches and updates
- Snapshot provider information
- Important notes on &newProductName;
- &newProductName; installation problems
- FlashBackup and status code 13
- Single file restore from a FlashBackup Instant Recovery snapshot of a file protected by Windows VSS writer fails
- Identifying and removing a left-over snapshot
- Removing a VxVM volume clone
- Alternate client restore and backup from a snapshot fails
- Restore from a snapshot fails with status 2800
- Raw Partition restore fails with the message 'FlashBackup-Windows policy restore error'
- Snapshot creation fails with error 156
- Snapshot fails with error 20
- Restore from a snapshot fails with status 133
- Backup from snapshot fails with error 50
- Backup from snapshot parent job fails with error 4213: Snapshot import failed
- Snapshot job fails and the snapshot command does not recognize the volume name
- Snapshot creation fails with error 4220
- Snapshot creation fails when the same volume is mounted on multiple mount points of the same host
- Snapshot-based backup and restore failure
- Multiple snapshot jobs fail with code 156 or 1541.
- FlashBackup policy fails, with multiple backup selections [Cache =]
- Partial backup failure with 'Snapshot encountered error 156'
- Backup of file system validation fails with error 223
- Policy validation fails if the specified CIFS share path contains a forward slash
- Policy validation fails with status code 223
- An NDMP snapshot policy for wildcard backup fails with error 4201
- Troubleshooting with bpfis log
- Limitations of using HP-UX 11.31
- While configuring a policy for snapshot operations, the NetBackup Administration Console hangs
- Accelerator enabled incremental backup of NetApp NAS volume
- Snapshot method: Auto
- Appendix A. Managing nbu_snap (Solaris)
- Appendix B. Overview of snapshot operations
- Index
Verifying NetBackup client access, zoning, and LUN masking
You can use the nbfirescan command to verify the following: that NetBackup clients have access to the array devices, and that the arrays are properly zoned and LUNs are unmasked. Note that nbfirescan only displays LUNs that have been unmasked and mapped to the host.
To verify NetBackup client access, zoning, and LUN masking
- Enter the following on the client:
/usr/openv/netbackup/bin/nbfirescan
This command queries the host's SCSI bus for all the SCSI (or Fibre) attached devices that are visible.
Example output from an AIX host, for Hitachi and IBM arrays, followed by a description:
DevicePath Vendor Product ID EnclosureId DeviceId [Ctl,Bus,Tgt,Lun] ------------------------------------------------------------------------- /dev/hdisk8 HITACHI OPEN-V-CM 10266 241 [00,00,144640,00] /dev/hdisk9 HITACHI OPEN-V 10266 840 [00,00,144640,01] /dev/hdisk45 IBM 1814 FAStT IBM.1814-600A0B800042212 2000000004804132760:0A:0B:80:00:42:33:6E:00:00:16:EF:48:DC:3C:1F [00,00 ,327936,01] /dev/hdisk46 IBM 1814 FAStT IBM.1814-600A0B800042212 2000000004804132760:0A:0B:80:00:42:33:6E:00:00:16:F7:48:DC:57:F3 [00,00 ,327936,02] /dev/hdisk43 IBM 1814 FAStT IBM.1814-600A0B800042212 2000000004804132760:0A:0B:80:00:42:33:6E:00:00:14:A4:48:AA:52:87 [00,00 ,327936,03] /dev/rdsk/c2t6d11s6 HITACHI DF600F 6484 48 [00,00,00,00] /dev/rdsk/c2t6d10s6 HITACHI DF600F 6484 46 [00,00,00,00] /dev/rdsk/c2t10d3s6 HITACHI OPEN-V -SUN 45027 18 [00,00,00,00] /dev/rdsk/c2t10d0s6 HITACHI OPEN-V-CM 45027 0 [00,00,00,00]
Note the following descriptions:
DevicePath
Represents the actual access point for the device as it exists on the client host.
EnclosureId
Unique for each physical disk array.
DeviceId
Unique for a physical disk or virtual disk in an enclosure. The EnclosureId/DeviceId pair constitutes a host-independent designation of a particular physical or virtual disk within a disk array.
Ctl,Bus,Tgt,LUN
Controller, bus, target, and LUN numbers are the elements that designate a particular physical or virtual disk from the perspective of the client host computer.
More Information