Please enter search query.
Search <book_title>...
NetBackup™ Deployment Guide for Kubernetes Clusters
Last Published:
2024-06-17
Product(s):
NetBackup (10.4.0.1)
- Introduction
- Section I. Configurations
- Prerequisites
- Recommendations and Limitations
- Configurations
- Configuration of key parameters in Cloud Scale deployments
- Section II. Deployment
- Section III. Monitoring and Management
- Monitoring NetBackup
- Monitoring Snapshot Manager
- Monitoring MSDP Scaleout
- Managing NetBackup
- Managing the Load Balancer service
- Managing PostrgreSQL DBaaS
- Performing catalog backup and recovery
- Managing MSDP Scaleout
- Section IV. Maintenance
- MSDP Scaleout Maintenance
- PostgreSQL DBaaS Maintenance
- Patching mechanism for Primary and Media servers
- Upgrading
- Cloud Scale Disaster Recovery
- Uninstalling
- Troubleshooting
- Troubleshooting AKS and EKS issues
- View the list of operator resources
- View the list of product resources
- View operator logs
- View primary logs
- Socket connection failure
- Resolving an issue where external IP address is not assigned to a NetBackup server's load balancer services
- Resolving the issue where the NetBackup server pod is not scheduled for long time
- Resolving an issue where the Storage class does not exist
- Resolving an issue where the primary server or media server deployment does not proceed
- Resolving an issue of failed probes
- Resolving token issues
- Resolving an issue related to insufficient storage
- Resolving an issue related to invalid nodepool
- Resolving a token expiry issue
- Resolve an issue related to KMS database
- Resolve an issue related to pulling an image from the container registry
- Resolving an issue related to recovery of data
- Check primary server status
- Pod status field shows as pending
- Ensure that the container is running the patched image
- Getting EEB information from an image, a running container, or persistent data
- Resolving the certificate error issue in NetBackup operator pod logs
- Pod restart failure due to liveness probe time-out
- NetBackup messaging queue broker take more time to start
- Host mapping conflict in NetBackup
- Issue with capacity licensing reporting which takes longer time
- Local connection is getting treated as insecure connection
- Primary pod is in pending state for a long duration
- Backing up data from Primary server's /mnt/nbdata/ directory fails with primary server as a client
- Storage server not supporting Instant Access capability on Web UI after upgrading NetBackup
- Taint, Toleration, and Node affinity related issues in cpServer
- Operations performed on cpServer in environment.yaml file are not reflected
- Elastic media server related issues
- Failed to register Snapshot Manager with NetBackup
- Post Kubernetes cluster restart, flexsnap-listener pod went into CrashLoopBackoff state or pods were unable to connect to flexsnap-rabbitmq
- Post Kubernetes cluster restart, issues observed in case of containerized Postgres deployment
- Troubleshooting AKS-specific issues
- Troubleshooting EKS-specific issues
- Troubleshooting AKS and EKS issues
- Appendix A. CR template
Adding MSDP engines
You can add new MSDP engines by updating the CR. You can add maximum 16 MSDP engines.
Prerequisites:
Allocate new static IP/FQDN pairs in the same node resource group.
The node number must not be less than the MSDP Scaleout size that you plan to change.
CR YAML file of MSDP Scaleout
To add the MSDP engines by updating the CR YAML file
- Open the CR YAML file to edit.
- Append the new IP/FQDN pairs in the spec.serviceIPFQDNs field.
- Update the spec.size field to increase the cluster size accordingly.
- Apply new CR YAML to update the CR in the Kubernetes environment.
kubectl apply -f <your-cr-yaml>
To add the MSDP engines using the kubectl command directly
- Run the following command to append the IP/FQDN pairs in the spec.serviceIPFQDNs field and increase the cluster size in spec.size field.
kubectl -n <sample-namespace> edit msdpscaleout <your-cr-name> [-o json | yaml]
The MSDP Scaleout services are not interrupted when MSDP engines are added.