NetBackup IT Analytics Certified Configuration Guide
- Introduction
 - Portal and database servers
 - Data Collector server configurations
 - Capacity Manager configurations
- Supported systems and access requirements
 - IBM Arrays: Modify profile
 - Creating a NetApp user with API privileges
 - Creating a NetApp cluster-mode user with API privileges
 - Array/LUN performance Data Collection
 - EMC Isilon array performance metrics
 - NetApp Cluster-Mode performance metrics
- NetApp Cluster-Mode Aggregate Performance
 - NetApp Cluster-Mode CIFS Performance
 - NetApp Cluster-Mode Disk Performance
 - NetApp Cluster-Mode Fiber Channel Protocol Logical Interface Performance
 - NetApp Cluster-Mode LUN Performance
 - NetApp Cluster-Mode NFS Performance
 - NetApp Cluster-Mode Processor Node Performance
 - NetApp Cluster-Mode Processor Performance
 - NetApp Cluster-Mode RAID Performance
 - NetApp Cluster-Mode SMB (Server Message Block) Performance
 - NetApp Cluster-Mode System Performance
 - NetApp Cluster-Mode Target Port Performance
 - NetApp Cluster-Mode Volume Performance
 
 - EMC Symmetrix enhanced performance metrics
- Create enhanced EMC Symmetrix Performance report templates
 - EMC Symmetrix Array Performance
 - EMC Symmetrix Backend Director Performance
 - EMC Symmetrix Frontend Director Performance
 - EMC Symmetrix Front-end Port Performance
 - EMC Symmetrix Storage Group Performance
 - EMC Symmetrix Database Performance
 - EMC Symmetrix Disk Group Performance
 - EMC Symmetrix Disk Performance
 - EMC Symmetrix Device Groups Performance
 - EMC Symmetrix Disk by Technology Performance
 - EMC Symmetrix Storage Tier Performance
 - EMC Symmetrix Thin Tier Performance
 - EMC Symmetrix Thin Pool Performance
 - EMC Symmetrix Enhanced Performance metrics
 
 - Hitachi Vantara array performance metrics
 - Host resources prerequisites and configurations
 - Host access privileges, sudo commands, ports, and WMI proxy requirements
 - WMI proxy requirements for Windows host Data Collection
 - Host resources supported configurations
 - Pure Storage Flash Array performance metrics
 - Supported host bus adapters (HBAs)
 - Compute Resources supported configurations
 
 - Cloud configurations
 - Virtualization Manager configurations
 - File Analytics configurations
 - Fabric Manager configurations
 - Backup Manager configurations
 - ServiceNow configurations
 - Internal TCP port requirements
 
Switch vendors
Note:
Refer to the Software and hardware disclaimer supported and tested by Veritas.
See Software and hardware disclaimer.
Fabric Manager provides reports that include topological views of the interrelationships of objects attached to the switches--end-to-end paths for objects such as LUNs and File Systems. Fabric Manager can collect data for the following switches.
Table: Switch information to collect
Vendor  | Agent/Interface  | Notes  | 
|---|---|---|
Brocade  | Preferred SMI Integrated Agents: 
 REST API exposed by Brocade Switches with FOS version - 8.1.x and above and 9.0.x Collection Method: Command Line Interface (CLI) exposed by Brocade Switches with Brocade FOS versions 7.4.x, 8.x, 9.0.x, 9.1.x, and 9.2.x  | 
 Brocade Server Address*: This field is enabled if Collection Method is Command Line Interface (CLI). Specify only one Principal Switch IP address or fully qualified one Switch name for the Brocade Switch. Note: The port number is optional. The format should be: <ip_address>[:port_number]. Note: When collection method is Command Line Interface, TCP port 22 and UDP port 161 on Brocade Switch must be open, and those must be accessible to Data Collector.  | 
Cisco  | Preferred SMI Agent: 
  | 
  |