- Introduction
- Upgrading Access Appliance
- Installing EEBs using the UI
Running a pre-check from the appliance shell menu
Use the following procedure to run the pre-check from the appliance shell menu:
To run a pre-upgrade check:
- Open an SSH session and use the admin credentials to log in the appliance.
The Veritas Appliance Shell menu is displayed.
- To run the pre-upgrade check run the following command:
start appliance preupgrade-check patch=update_name
where update-name is the name of the software update that you want to install.
- Monitor the pre-upgrade check and ensure that all the pre-upgrade checks pass successfully. To check the status, run the show appliance preupgrade-check status command.
Note:
Wait for a few seconds before you check the status. If you check the status immediately after running the preupgrade-check command, the status of the preupgrade checks might not be available. If you check the status without running the preupgrade-check command, Operation failed error message is displayed.