Veritas InfoScale™ Operations Manager 7.4 Add-ons User's Guide
- Section I. VCS Utilities Add-on 7.4
- Section II. Distribution Manager Add-on 7.4
- Section III. Fabric Insight Add-on 7.4
- Section IV. Patch Installer Add-on 7.4
- Introduction to Patch Installer Add-on
- Using Patch Installer Add-on
- Prerequisites for deploying SFHA hot fixes
- Deploying SFHA hot fixes
- Requirements for scripts to customize SFHA hot fix deployment
- Adding pre-installation and post-installation scripts to SFHA hot fixes
- Removing or replacing custom scripts for SFHA hot fixes
- Viewing information about SFHA hot fix deployment requests
- Section V. Storage Insight Add-on 7.4
- Performing the deep discovery of enclosures
- About Storage Insight Add-on
- About the discovery host
- About the network-attached storage discovery
- Adding HITACHI storage enclosures for deep discovery
- Adding EMC Symmetrix storage enclosures for deep discovery
- Adding IBM XIV storage enclosures for deep discovery
- Adding NetApp storage enclosures for deep discovery
- Adding EMC CLARiiON storage enclosures for deep discovery
- Adding HP EVA storage enclosures for deep discovery
- Adding IBM System Storage DS enclosures for deep discovery
- Adding EMC Celerra storage enclosures for deep discovery
- Adding EMC VNX storage enclosures for deep discovery
- Adding EMC VPLEX storage enclosures for deep discovery
- Adding 3PAR storage enclosures for deep discovery
- Adding IBM SVC storage enclosures for deep discovery
- Editing the deep discovery configuration for an enclosure
- Removing deep discovery for a storage enclosure
- Refreshing the enclosures that are configured for deep array discovery
- Monitoring the usage of thin pools
- Monitoring storage array metering data
- Managing LUN classifications
- Appendix A. Enclosure configuration prerequisites
- HITACHI enclosure configuration prerequisites
- EMC Symmetrix storage array configuration prerequisites
- Physical connection requirements for EMC Symmetrix enclosure
- Device setup requirements for EMC Symmetrix arrays
- Veritas InfoScale Operations Manager setup requirements for in-band EMC Symmetrix storage arrays
- Veritas InfoScale Operations Manager setup requirements to discover EMC Symmetrix storage arrays through remote SYMAPI servers
- IBM XIV enclosure configuration prerequisites
- NetApp storage enclosure configuration prerequisites
- EMC CLARiiON storage enclosures configuration prerequisites
- Hewlett-Packard Enterprise Virtual Array (HP EVA) configuration prerequisites
- IBM System Storage DS enclosure configuration prerequisites
- IBM SVC enclosure configuration prerequisites
- EMC Celerra enclosure configuration prerequisites
- EMC VNX storage enclosure configuration prerequisites
- EMC VPLEX storage enclosure configuration prerequisites
- 3PAR storage enclosure configuration prerequisites
- Appendix B. Commands used by Management Server for deep discovery of enclosures
- HITACHI storage enclosure commands
- EMC Symmetrix storage enclosure commands
- IBM XIV storage enclosures commands
- NetApp storage enclosure commands
- EMC CLARiiON storage enclosure commands
- HP EVA storage enclosure commands
- IBM System Storage DS enclosure commands
- EMC Celerra storage enclosure commands
- EMC VNX (Block) storage enclosure commands
- EMC VNX (File) storage enclosure commands
- EMC VPLEX storage enclosure commands
- 3PAR storage enclosure commands
- IBM SVC storage enclosure commands
- Performing the deep discovery of enclosures
- Section VI. Storage Insight SDK Add-on 7.4
- Overview of Storage Insight SDK Add-on 7.4
- Managing Veritas InfoScale Operations Manager Storage Insight plug-ins
- About creating Storage Insight plug-in
- About installing Storage Insight SDK Add-on
- About discovery script
- About the enclosure discovery command output
- --list encls command to discover all enclosures
- --list pdevs --encl enclosure Id command to discover all physical disks in an enclosure
- --list ldevs --encl enclosure Id command to discover all logical disks for an enclosure
- --list adapters --encl enclosure Id command to discover all adapters of an enclosure
- --list ports --encl enclosure Id command to discover all ports for an enclosure
- --list capacities --encl enclosure Id command to discover aggregate physical, RAID group, and logical capacities for an enclosure
- --list ldevpdevmap --encl enclosure Id command to discover logical disk-physical disk mapping for an enclosure
- --list ldevhostmap --encl enclosure Id command to discover logical device-host mapping for an enclosure
- --list meta-ldevs --encl enclosure Id command to discover the mapping of meta logical disks with segment logical disks for an enclosure
- --list raidgroups --encl enclosure Id command to discover RAID groups for an enclosure
- --list thinpools --encl enclosure Id command to discover all thin pools for an enclosure
- --list rgpdevmap --encl enclosure Id command to discover RAID group-physical disk mapping for an enclosure
- --list rgldevmap --encl enclosure Id command to discover RAID group-logical device mapping for an enclosure
- --list tpsrcldevmap --encl enclosure Id command to discover thin pool-source logical device mapping for an enclosure
- --list tpldevmap --encl enclosure Id command to discover thin pool logical device mapping for an enclosure
- --list replications --encl enclosure Id command to discover the replications for an enclosure
- About additional scripts
- About device identifiers
- Storage Insight Plug-in sample
- Creating a Storage Insight plug-in
- Editing a Storage Insight plug-in
- Testing a Storage Insight plug-in
- About creating Storage Insight plug-in
- Section VII. Storage Provisioning and Enclosure Migration Add-on 7.4
- Provisioning storage
- About storage provisioning
- About creating a storage template
- Creating a storage template using VxFS file systems
- Creating a storage template using NTFS file systems
- Creating a storage template using volumes
- Updating a storage template
- Provisioning storage
- Uploading storage templates
- Downloading storage templates
- Deleting storage templates
- Locking storage templates
- Unlocking storage templates
- Migrating volumes
- Provisioning storage
- Section VIII. Veritas HA Plug-in for VMware vSphere Web Client
- Introduction to Veritas HA Plug-in for vSphere Web Client
- Installation and uninstallation of Veritas HA Plug-in for vSphere Web Client
- Configurations for Veritas HA Plug-in for vSphere Web Client
- Registering the HA Plug-in with VMware vCenter Server
- Unregistering the HA Plug-in from VMware vCenter Server
- Deploying the HA Plug-in if the Management Server is configured in a high availability environment
- Adding managed hosts to the Management Server
- Migrating virtual machines to Veritas InfoScale Operations Manager
- Section IX. Application Migration Add-on
- Introduction to Application Migration Add-on
- Creating and managing an application migration plan
- Supported versions and platforms
- User privileges
- Prerequisites for creating an application migration plan
- Prerequisites for migration to AWS
- VVR Replication: Environment variables used in application migration
- Creating an application migration plan
- Understanding user-defined tasks
- Understanding application migration operations
- Understanding the cleanup operation
- Understanding the tasks executed in each operation
- Validations performed before migration plan execution
- Executing the application migration plan
- Editing an application migration plan
- Deleting application migration plan(s)
- Exporting application migration plan(s)
- Importing application migration plan(s)
- Viewing historical runs
- Viewing properties of an application migration plan
- Application migration logs
Add switch panel options for specifying discovery host and other information for Cisco switch discovery
Use this wizard panel to specify the discovery host, seed switch, and other parameters that are required for the discovery of Cisco switches.
Table: Add switch panel options for specifying discovery host and other information for Cisco switch discovery
Field | Description |
|---|---|
Switch Vendor | Displays the switch vendor. |
Discovery Method | Displays the discovery method for the discovery of the Cisco switch. |
Discovery Host | Select the discovery host. |
Seed Switch Name/IP | Enter the name or the IP address of the seed switch that is required for the discovery. For Cisco, a switch in the N Port Virtualization (NPV) mode should not be configured as a seed switch. |
SNMP Version | Select the SNMP version to be used for the SNMP communication. |
SNMPv3 | The options in this section are available only when you select in the SNMP Version field. User Name: Enter the name of the SNMP user. The user must have at least network-operator role. Security Level: Select the appropriate security level from the drop-down list. The available levels are NoAuthNoPriv, AuthNoPriv, and AuthPriv. Authentication Protocol: Select the authentication protocol. It is applicable to AuthNoPriv and AuthPriv security levels. Authentication Password: Enter the authentication password for the user. It is applicable to AuthNoPriv, and AuthPriv security levels. Privacy Protocol: Select the privacy protocol. It is applicable to AuthPriv security level. Privacy Password: Enter the privacy password for the SNMP user. It is applicable to AuthPriv security level. |
SNMPv1/2c | The option in this section is available only when you select SNMPv1/2c in the SNMP Version field. Community String: Enter the SNMP community string. The community can be read-only or read-write. |
More Information