Veritas Access Appliance Command Reference Guide

Last Published:
Product(s): Appliances (7.4.3)
Platform: Veritas 3340,Access Appliance OS
  1. Overview
    1.  
      Scope of the Veritas Access Command Reference Guide
    2.  
      Where to find the documentation
    3.  
      Using the Access Appliance shell menu
  2. Appendix A. Main > Appliance
    1.  
      Appliance > Status
  3. Appendix B. Main > Manage > Cluster
    1.  
      Cluster > Configure
  4. Appendix C. Main > Manage > Software
    1.  
      Manage > Software > Cancel
    2.  
      Manage > Software > Delete
    3.  
      Manage > Software > Download
    4.  
      Manage > Software > DownloadProgress
    5.  
      Manage > Software > Install
    6.  
      Manage > Software > List
    7.  
      Manage > Software > Readme
    8.  
      Manage > Software > Rollback
    9.  
      Manage > Software > Share
    10.  
      Manage > Software > UpgradeStatus
  5. Appendix D. Main > Manage > Storage
    1.  
      Manage > Storage > Show
    2.  
      Manage > Storage > Scan
    3.  
      Manage > Storage > Erase
  6. Appendix E. Main > Monitor
    1.  
      Monitor > Beacon
    2.  
      Monitor > MemoryStatus
    3.  
      Monitor > NetworkStatus
    4.  
      Monitor > SDCS
    5.  
      Monitor > Top
    6.  
      Monitor > Uptime
    7.  
      Monitor > Who
    8.  
      Monitor > Hardware
  7. Appendix F. Main > Network
    1.  
      Network > Configure
    2.  
      Network > Date
    3.  
      Network > DNS
    4.  
      Network > Gateway
    5.  
      Network > Hostname
    6.  
      Network > Hosts
    7.  
      Network > IPv4
    8.  
      Network > IPv6
    9.  
      Network > NetStat
    10.  
      Network > NTPServer
    11.  
      Network > Ping
    12.  
      Network > Proxy
    13.  
      Network > SetProperty
    14.  
      Network > Show
    15.  
      Network > TimeZone
    16.  
      Network > TraceRoute
    17.  
      Network > Unconfigure
  8. Appendix G. Main > Settings
    1.  
      Settings > Password
    2.  
      Settings > Alerts > CallHome
    3.  
      Settings > Alerts > Email
    4.  
      Settings > Alerts > Hardware
    5.  
      Settings > Alerts > SNMP
    6.  
      Settings > LogForwarding
    7.  
      Security > Certificates > DeviceCertificate > Export
    8.  
      Security > Certificates > DeviceCertificate > Import
  9. Appendix H. Main > Support
    1.  
      Support > Cleanup > ResetDIMMErrors
    2.  
      Support > Collect
    3.  
      Support > DataCollect
    4.  
      Support > FactoryReset
    5.  
      Support > InfraServices
    6.  
      Support > IPMI
    7.  
      Support > LogBrowser
    8.  
      Support > Logs
    9.  
      Support > Maintenance
    10.  
      Support > RAID
    11.  
      Support > Reboot
    12.  
      Support > Services
    13.  
      Support > Shutdown
    14.  
      Support > Storage Reset
    15.  
      Support > Test

Name

main > Monitor > Beacon — Start or stop flashing hard disk drive LEDs

SYNOPSIS

Beacon Start WWID

Beacon Stop WWID

Beacon Start HDD

Beacon Stop HDD

DESCRIPTION

Use this command to operate the LEDs of a disk drive. This command enables you to flash or stop flashing the LEDs of a disk drive.

OPTIONS

Beacon Start WWID MINS WWID

Start flashing the LEDs by WWID of the disk drive. Minutes is the duration of time, in minutes, that LEDs can flash. If the specified WWID is not valid, the WWID of all the disk drives in the appliance are displayed.

Beacon Stop WWID WWID

Stop flashing the LEDs by WWID of disk drive. If the specified WWID is not valid, the WWID of all the disk drives in the appliance are displayed.

Beacon Start HDD MINS EID [SID]

Start flashing the LEDs by Enclosure ID and Slot ID of the disk drive. Minutes is the duration of time, in minutes, that lights can flash. The slot ID is set to a default value of all. If slot ID is not specified, LEDs of the entire enclosure start flashing. For the Enclosure ID, you can set the value to 0 or 62. The EID 0 represents the disk drives located in the primary storage shelf and 62 represents the drives located in the compute node.

Beacon Stop HDD EID [SID]

Stop flashing the LEDs by Enclosure ID and Slot ID of a disk drive. The slot ID is set to the default value of all. If slot ID is not specified, LEDs of the whole enclosure stop flashing.