Veritas InfoScale™ 7.3.1 Troubleshooting Guide - Solaris
- Introduction
- Section I. Troubleshooting Veritas File System
- Section II. Troubleshooting Veritas Volume Manager
- Recovering from hardware failure
- About recovery from hardware failure
- Listing unstartable volumes
- Displaying volume and plex states
- The plex state cycle
- Recovering an unstartable mirrored volume
- Recovering an unstartable volume with a disabled plex in the RECOVER state
- Forcibly restarting a disabled volume
- Clearing the failing flag on a disk
- Reattaching failed disks
- Recovering from a failed plex attach or synchronization operation
- Failures on RAID-5 volumes
- Recovering from an incomplete disk group move
- Restarting volumes after recovery when some nodes in the cluster become unavailable
- Recovery from failure of a DCO volume
- Recovering from instant snapshot failure
- Recovering from the failure of vxsnap prepare
- Recovering from the failure of vxsnap make for full-sized instant snapshots
- Recovering from the failure of vxsnap make for break-off instant snapshots
- Recovering from the failure of vxsnap make for space-optimized instant snapshots
- Recovering from the failure of vxsnap restore
- Recovering from the failure of vxsnap refresh
- Recovering from copy-on-write failure
- Recovering from I/O errors during resynchronization
- Recovering from I/O failure on a DCO volume
- Recovering from failure of vxsnap upgrade of instant snap data change objects (DCOs)
- Recovering from failed vxresize operation
- Recovering from boot disk failure
- VxVM and boot disk failure
- Possible root, swap, and usr configurations
- Booting from an alternate boot disk on Solaris SPARC systems
- The boot process on Solaris SPARC systems
- Hot-relocation and boot disk failure
- Recovery from boot failure
- Repair of root or /usr file systems on mirrored volumes
- Replacement of boot disks
- Recovery by reinstallation
- Managing commands, tasks, and transactions
- Backing up and restoring disk group configurations
- Troubleshooting issues with importing disk groups
- Recovering from CDS errors
- Logging and error messages
- Troubleshooting Veritas Volume Replicator
- Recovery from RLINK connect problems
- Recovery from configuration errors
- Errors during an RLINK attach
- Errors during modification of an RVG
- Recovery on the Primary or Secondary
- About recovery from a Primary-host crash
- Recovering from Primary data volume error
- Primary SRL volume error cleanup and restart
- Primary SRL volume error at reboot
- Primary SRL volume overflow recovery
- Primary SRL header error cleanup and recovery
- Secondary data volume error cleanup and recovery
- Secondary SRL volume error cleanup and recovery
- Secondary SRL header error cleanup and recovery
- Secondary SRL header error at reboot
- Troubleshooting issues in cloud deployments
- Recovering from hardware failure
- Section III. Troubleshooting Dynamic Multi-Pathing
- Section IV. Troubleshooting Storage Foundation Cluster File System High Availability
- Troubleshooting Storage Foundation Cluster File System High Availability
- About troubleshooting Storage Foundation Cluster File System High Availability
- Troubleshooting CFS
- Troubleshooting fenced configurations
- Troubleshooting Cluster Volume Manager in Veritas InfoScale products clusters
- CVM group is not online after adding a node to the Veritas InfoScale products cluster
- Shared disk group cannot be imported in Veritas InfoScale products cluster
- Unable to start CVM in Veritas InfoScale products cluster
- Removing preexisting keys
- CVMVolDg not online even though CVMCluster is online in Veritas InfoScale products cluster
- Shared disks not visible in Veritas InfoScale products cluster
- Troubleshooting Storage Foundation Cluster File System High Availability
- Section V. Troubleshooting Cluster Server
- Troubleshooting and recovery for VCS
- VCS message logging
- Log unification of VCS agent's entry points
- Enhancing First Failure Data Capture (FFDC) to troubleshoot VCS resource's unexpected behavior
- GAB message logging
- Enabling debug logs for agents
- Enabling debug logs for IMF
- Enabling debug logs for the VCS engine
- About debug log tags usage
- Gathering VCS information for support analysis
- Gathering LLT and GAB information for support analysis
- Gathering IMF information for support analysis
- Message catalogs
- Troubleshooting the VCS engine
- Troubleshooting Low Latency Transport (LLT)
- Troubleshooting Group Membership Services/Atomic Broadcast (GAB)
- Troubleshooting VCS startup
- Troubleshooting Intelligent Monitoring Framework (IMF)
- Troubleshooting service groups
- VCS does not automatically start service group
- System is not in RUNNING state
- Service group not configured to run on the system
- Service group not configured to autostart
- Service group is frozen
- Failover service group is online on another system
- A critical resource faulted
- Service group autodisabled
- Service group is waiting for the resource to be brought online/taken offline
- Service group is waiting for a dependency to be met.
- Service group not fully probed.
- Service group does not fail over to the forecasted system
- Service group does not fail over to the BiggestAvailable system even if FailOverPolicy is set to BiggestAvailable
- Restoring metering database from backup taken by VCS
- Initialization of metering database fails
- Troubleshooting resources
- Troubleshooting I/O fencing
- Node is unable to join cluster while another node is being ejected
- The vxfentsthdw utility fails when SCSI TEST UNIT READY command fails
- Manually removing existing keys from SCSI-3 disks
- System panics to prevent potential data corruption
- Cluster ID on the I/O fencing key of coordinator disk does not match the local cluster's ID
- Fencing startup reports preexisting split-brain
- Registered keys are lost on the coordinator disks
- Replacing defective disks when the cluster is offline
- The vxfenswap utility exits if rcp or scp commands are not functional
- Troubleshooting CP server
- Troubleshooting server-based fencing on the Veritas InfoScale products cluster nodes
- Issues during online migration of coordination points
- Troubleshooting notification
- Troubleshooting and recovery for global clusters
- Troubleshooting the steward process
- Troubleshooting licensing
- Validating license keys
- Licensing error messages
- [Licensing] Insufficient memory to perform operation
- [Licensing] No valid VCS license keys were found
- [Licensing] Unable to find a valid base VCS license key
- [Licensing] License key cannot be used on this OS platform
- [Licensing] VCS evaluation period has expired
- [Licensing] License key can not be used on this system
- [Licensing] Unable to initialize the licensing framework
- [Licensing] QuickStart is not supported in this release
- [Licensing] Your evaluation period for the feature has expired. This feature will not be enabled the next time VCS starts
- Verifying the metered or forecasted values for CPU, Mem, and Swap
- VCS message logging
- Troubleshooting and recovery for VCS
- Section VI. Troubleshooting SFDB
Fencing startup reports preexisting split-brain
The vxfen driver functions to prevent an ejected node from rejoining the cluster after the failure of the private network links and before the private network links are repaired.
For example, suppose the cluster of system 1 and system 2 is functioning normally when the private network links are broken. Also suppose system 1 is the ejected system. When system 1 restarts before the private network links are restored, its membership configuration does not show system 2; however, when it attempts to register with the coordinator disks, it discovers system 2 is registered with them. Given this conflicting information about system 2, system 1 does not join the cluster and returns an error from vxfenconfig that resembles:
vxfenconfig: ERROR: There exists the potential for a preexisting split-brain. The coordinator disks list no nodes which are in the current membership. However, they also list nodes which are not in the current membership. I/O Fencing Disabled!
Also, the following information is displayed on the console:
<date> <system name> vxfen: WARNING: Potentially a preexisting <date> <system name> split-brain. <date> <system name> Dropping out of cluster. <date> <system name> Refer to user documentation for steps <date> <system name> required to clear preexisting split-brain. <date> <system name> <date> <system name> I/O Fencing DISABLED! <date> <system name> <date> <system name> gab: GAB:20032: Port b closed
However, the same error can occur when the private network links are working and both systems go down, system 1 restarts, and system 2 fails to come back up. From the view of the cluster from system 1, system 2 may still have the registrations on the coordination points.
Assume the following situations to understand preexisting split-brain in server-based fencing:
There are three CP servers acting as coordination points. One of the three CP servers then becomes inaccessible. While in this state, one client node leaves the cluster, whose registration cannot be removed from the inaccessible CP server. When the inaccessible CP server restarts, it has a stale registration from the node which left the VCS. In this case, no new nodes can join the cluster. Each node that attempts to join the cluster gets a list of registrations from the CP server. One CP server includes an extra registration (of the node which left earlier). This makes the joiner node conclude that there exists a preexisting split-brain between the joiner node and the node which is represented by the stale registration.
All the client nodes have crashed simultaneously, due to which fencing keys are not cleared from the CP servers. Consequently, when the nodes restart, the vxfen configuration fails reporting preexisting split brain.
These situations are similar to that of preexisting split-brain with coordinator disks, where you can solve the problem running the vxfenclearpre command. A similar solution is required in server-based fencing using the cpsadm command.