Veritas Access Appliance Initial Configuration Guide

Last Published:
Product(s): Appliances (7.4.3)
Platform: Veritas 3340,Access Appliance OS
  1. Getting to know the Access Appliance
    1.  
      About the Veritas Access Appliance
    2. About the Access Appliance administration interfaces
      1.  
        Using the Access Appliance shell menu
    3.  
      About licensing the Access Appliance
    4.  
      Where to find the documentation
  2. Preparing to configure the appliance
    1.  
      Initial configuration requirements
    2.  
      About obtaining IP addresses for Veritas Access
    3.  
      Network and firewall requirements
  3. Configuring the appliance for the first time
    1. How to configure the Access Appliance for the first time
      1.  
        Configuring the Access cluster on the appliance
  4. Getting started with the Veritas Access GUI
    1.  
      Accessing the Veritas Access web interface
  5. Storage management
    1.  
      About the appliance storage
    2.  
      Viewing the storage on the appliance
    3.  
      Scanning the storage on the appliance
  6. Network connection management
    1. Configuring network address settings on the appliance nodes
      1.  
        About NIC1 (eth0) port usage on the appliance nodes
      2.  
        About IPv4-IPv6-based network support on the Access Appliance
    2.  
      Configuring static routes on the appliance
    3.  
      Configuring DNS settings on the appliance
    4.  
      Configuring host name on the appliance
    5.  
      About the maximum transmission unit size on the appliance
    6. About the Veritas Remote Management Console
      1.  
        Configuring the IPMI port on an appliance node
      2.  
        Managing IPMI users on an appliance node
      3.  
        Resetting the IPMI on an appliance node
    7.  
      Setting the date and time on the appliance
  7. Monitoring the appliance
    1.  
      About hardware monitoring in the Access GUI
    2. About Veritas AutoSupport on the Access Appliance
      1.  
        Setting up AutoSupport on the appliance
      2.  
        Using a proxy server with the appliance
    3.  
      Setting up email notifications on the appliance
    4.  
      Setting up SNMP notifications on the appliance
    5.  
      Testing the appliance hardware
  8. Resetting the appliance to factory settings
    1.  
      About appliance factory reset
    2.  
      Performing factory reset for cluster nodes
    3.  
      Performing factory reset for a node not in a cluster
  9. Appliance security
    1.  
      About Access Appliance security
    2. About Access appliance user account privileges
      1. Access appliance admin password specifications
        1.  
          Password encryption and handling on the Access appliance
    3.  
      About forced password changes
    4.  
      Changing the Maintenance user account password
    5. About the Access Appliance intrusion detection system
      1.  
        Reviewing SDCS events on the Access Appliance
      2.  
        Auditing the SDCS logs on an Access Appliance
      3.  
        About SDCS event type codes and severity codes on an Access appliance node
      4.  
        Changing the SDCS log retention settings on an Access Appliance node
    6.  
      About the Access Appliance intrusion prevention system
    7. About Access appliance operating system security
      1.  
        Vulnerability scanning of the Access Appliance
      2.  
        Disabled service accounts on the Access appliance
    8.  
      About data security on the Access appliance
    9.  
      About data integrity on the Access appliance
    10. Recommended IPMI settings on the Access appliance
      1.  
        Replacing the default IPMI SSL certificate on the Access appliance

About the appliance storage

The Veritas Access 3340 Appliance must be connected to one Primary Storage Shelf. The storage space can be expanded by using up to three Expansion Storage Shelves. After you have physically connected the storage shelves, use the Access Appliance shell menu to discover and refresh the storage devices information. All the appliance nodes share the external storage that is attached to the appliance.

Note:

The Veritas Access 3340 compute nodes do not have internal disk space available for Access storage. Only the space available on the Primary Storage Shelf and Expansion Storage Shelves can be used for Access data.

The physical disk storage in the Primary Storage Shelf contains five Data volumes, five Fencing volumes, and one Configuration volume.

The physical disk storage in the Expansion Storage Shelf contains five Data volumes.

The Data, Fencing, and Configuration volumes are created when you scan the storage that is attached to the appliance. The Access software only uses the Data volumes to provision storage.