Veritas NetBackup™ 5240 Appliance Product Description
- About the NetBackup 5240 Appliance
- NetBackup 5240 Appliance front panel disk drive configurations
- NetBackup 5240 Appliance control panel
- NetBackup 5240 Appliance rear panel
- NetBackup 5240 Appliance I/O configuration options
- NetBackup 5240 Appliance I/O configuration options
- About the Veritas 2U12 49TB Storage Shelf
- NetBackup 5240 Appliance and Veritas 2U12 49TB Storage Shelf cables
- Appendix A. Technical specifications and compliance standards
- Regulatory, compliance, and certification information
NetBackup 5240 Appliance I/O configuration options
The rear panel of the NetBackup 5240 Appliance contains three PCIe riser card assemblies. PCIe riser card assemblies 1 and 2 each support three standard PCIe cards, while PCIe riser card assembly 3 supports two low profile PCIe cards. The slots are labeled 1 to 8. Slots 1, 2, and 3 are located in PCIe riser card assembly 2. Slots 4, 5, and 6 are located in PCIe riser card assembly 1, while slots 7 and 8 are located in PCIe riser card assembly 3.
The NetBackup 5240 Appliance supports multiple PCIe-based I/O configuration options. The following table shows the different I/O configuration options that are available.
Table: Available NetBackup 5240 Appliance PCIe-based I/O configuration options
I/O configuration option | Slot 1 * | Slot 2 | Slot 3 | Slot 4 | Slot 5 | Slot 6 | Slot 7 ** | Slot 8 *** |
---|---|---|---|---|---|---|---|---|
A | - | - | - | - | - | - | - | - |
B | - | - | - | - | - | 8Gb FC HBA 3 (FC-R) | - | - |
C | - | - | 10GbE NIC 1, 3, | - | - | 8Gb FC HBA 3 (FC-R) | - | - |
D **** | - | 8Gb FC HBA 3 (FC-R) | 10GbE NIC 1, 3 | 8Gb FC HBA 3 (FC-R) | 8Gb FC HBA 3 (FTMS) | 8Gb FC HBA 3 (FTMS) | - | - |
E **** | - | 8Gb FC HBA 3 (FC-R) | 8Gb FC HBA 3 | 8Gb FC HBA 3 (FC-R) | 8Gb FC HBA 3 (FTMS) | 8Gb FC HBA 3 (FTMS) | - | - |
F | - | - | 1GbE NIC 2 (4 port - RJ45) | - | - | 8Gb FC HBA 3 (FC-R) | - | - |
G † | - | 10GbE NIC 1, 3, | 10GbE NIC 1, 3, | - | 10GbE NIC 1, 3 | 8Gb FC HBA 3 (FC-R) | - | - |
H **** | - | 10GbE NIC 1, 3, (iSCSI capable) | 10GbE NIC 1, 3 | - | 8Gb FC HBA 3 (FTMS) | 8Gb FC HBA 3 (FTMS) | - | - |
J | - | - | 10GbE NIC 1, 3, | - | - | - | - | - |
K **** | - | 10GbE NIC 1, 3, | 10GbE NIC 1, 3, | 8Gb FC HBA 3 (FC-R) | 8Gb FC HBA 3 (FTMS) | 8Gb FC HBA 3 (FTMS) | - | - |
L | - | 10GbE NIC 1, 3, | 1GbE NIC 2 (4 port - RJ45) | - | - | 8Gb FC HBA 3 (FC-R) | - | - |
M **** | - | - | - | - | - | 16Gb FC HBA 3 (FC-R) | - | - |
N **** | - | 10GbE NIC 1, 3, | - | - | 16Gb FC HBA 3 (FC-R) | - | - | |
P **** | - | 16Gb FC HBA 3 (FC-R) | 10GbE NIC 1, 3, | 16Gb FC HBA 3 (FC-R) | 16Gb FC HBA 3 (FTMS) | 16Gb FC HBA 3 (FTMS) | - | - |
R **** | - | 16Gb FC HBA 3 (FC-R) | 16Gb FC HBA 3 | 16Gb FC HBA 3 (FC-R) | 16Gb FC HBA 3 (FTMS) | 16Gb FC HBA 3 (FTMS) | - | - |
S **** | - | - | 1GbE NIC 2 (4 port - RJ45) | - | - | 16Gb FC HBA 3 (FC-R) | - | - |
T **** | - | 10GbE NIC 1, 3, | 10GbE NIC 1, 3, | - | 10GbE NIC 1, 3 | 16Gb FC HBA 3 (FC-R) | - | - |
V **** | - | 10GbE NIC 1, 3, (iSCSI capable) | 10GbE NIC 1, 3, | - | 16Gb FC HBA 3 (FTMS) | 16Gb FC HBA 3 (FTMS) | - | - |
W **** | - | 10GbE NIC 1, 3, | 10GbE NIC 1, 3, | 16Gb FC HBA 3 (FC-R) | 16Gb FC HBA 3 (FTMS) | 16Gb FC HBA 3 (FTMS) | - | - |
X **** | - | 10GbE NIC 1, 3, | 1GbE NIC 2 (4 port - RJ45) | - | - | 16Gb FC HBA 3 (FC-R) | - | - |
† Includes the Veritas NetBackup™ 5240 CloudCatalyst Appliance * Slot 1 contains a factory installed PCIe RAID 6 controller when at least one Veritas 2U12 49TB Storage Shelf is purchased with the NetBackup 5240 Appliance. Otherwise, slot 1 is not populated and is reserved for future use. ** Slot 7 contains the NetBackup 5240 Appliance's internal PCIe raid controller. This RAID controller is used to create the RAID 1 Array for the disk drives on which the appliance operating system is installed. The operating system disk drives are located in slots 0 and 1 of the front panel. *** Slot 8 is reserved for the optional SAS tape-out adapter, which is used to connect external SAS devices to the NetBackup 5240 Appliance. PCIe card cable connection types: 1 Direct-Attach copper cable (also called a Twinaxial cable or Twinax) 2 Standard copper cable 3 Fiber optic cable | ||||||||
**** I/O configuration option notes:
|