Veritas™ 5260 Appliance Product Description Guide
- About the Veritas 5260 Appliance
- Veritas 5260 Appliance overview
- Features and components of the Veritas 5260 Appliance
- Locating the appliance serial number
- Veritas 5260 Appliance front panel drive configurations
- About the Veritas 5260 Appliance front panel USB port
- About the 5260 Appliance control panel
- About the 5260 Appliance rear panel
- Veritas 5260 Appliance I/O configuration options
- Veritas 2U12 65.5TiB/72TB Storage Shelf
- Veritas 5260 Appliance and Veritas 2U12 65.5TiB/72TB Storage Shelf cables
- Appendix A. Technical specifications, Environmental/Protocol standards, and Compliance standards
- Veritas 5260 Appliance technical specifications
- Veritas 2U12 65.5TiB/72TB Storage Shelf technical specifications
- Environmental specifications
- Protocol standards
- Regulatory, compliance, and certification information
- Product regulatory compliance
- Country approvals
- Product safety compliance
- Product EMC Compliance - Class A Compliance
- Product environmental compliance
- Index
Environmental specifications
Table: Veritas Appliance compute node environmental specifications
Specification | 5260 Appliance compute node |
|---|---|
Operating temperature | ASHRAE A2 (10°C to 35°C ) (50°F to 95°F) |
Non-operating temperature | -40 °C to 70 °C (-40 °F to 158 °F) The non-operating temperature is defined as the temperature of the system when the system is turned off. It is also referred to as the storage temperature. Veritas recommends that you do not store the system in an environment where the temperatures fall outside of the listed temperature range. |
Operating humidity (RH) | 20% RH to 80% RH |
Non-operating humidity | 8% RH to 90% RH |
Operating altitude (feet) | 3050 m (10,006 ft) |
Temperature gradient (per hour) | 10°C/h (50°F/h) |
See Veritas 5260 Appliance technical specifications.
See Veritas 2U12 65.5TiB/72TB Storage Shelf technical specifications.
See Protocol standards.