- Introduction
- Configuration requirements
- Best practices
- NetBackup Flex Scale tuning and sizing
- Troubleshooting NetBackup Flex Scale
- Collecting logs for cluster nodes
- Forwarding logs to an external server
- Troubleshooting NetBackup Flex Scale issues
Resource monitoring and remediation
In NetBackup Flex Scale 3.2.100, if memory utilization reaches the threshold of 97%, the NetBackup Flex Scale node is brought down. You can confirm that the node is down in the following ways.
The ASC
/log/autosupport/collector.log
file has a INFO level log entry with a value greater than or equal to 97. Search for the value of the memory used_percentage parameter in thecollector.log
file.A crash dump file gets created on the system default path.
The system logs have entry for node reboot.