Veritas Data Insight Software Compatibility List
List of ports
This section lists the default ports used by various Data Insight services, and devices that Data Insight communicates with.
Table: List of default ports
Default Port | Component |
|---|---|
Management Console, HTTPS, port 443 Communication service, HTTPS port 8383 DataInsightConfig service, port 8282 Workflow Service, HTTPS, port 8686 Standard RPC, ports 139 and 445 | Management Server |
Communication service, HTTPS port 8383 Standard RPC ports 139 and 445 DataInsightConfig service, port 8282 NetApp Cluster-Mode service, TCP port 8787 (configurable) Generic Collector service, HTTPS port 8585 (configurable) | Collector worker node\ Indexer plus Collector worker node |
Communication service, HTTPS port 8383 DataInsightConfig service, port 8282 | Indexer worker node |
For NetApp filers - HTTP port 80 (optional), standard RPC ports 139 and 445, 2049 (TCP,UDP) and 111 (TCP,UDP) for NFS For NetApp Cluster-Mode, HTTP port 80 On EMC Control Station - HTTP port 80 and HTTPS port 443 On Windows File Servers managed without an agent - Standard RPC ports 139 and 445 For Veritas File System servers - HTTPS port 5634, 2049 (TCP,UDP) and 111 (TCP,UDP) for NFS | File Server |
Communication Service, HTTPS port 8383 DataInsightConfig service, port 8282 Standard RPC ports 139 and 445 | Windows File Server agent node |
SharePoint web service is accessed over the same port as the configured web applications. This port on the SharePoint web servers should be accessible from the Collector node. | SharePoint web service |
Port 389 or 636 (for TLS) | LDAP Directory Server |
Ports 111 (TCP,UDP), 714 (TCP), 711 (UDP) | NIS Server |
Ports 111 (TCP,UDP), 714 (TCP), 711 (UDP) | NIS+ Server in NIS compatibility mode |
DataInsightOneDrive service, port 9090 | OneDrive |
DataInsightSPOnline service, port 9292 | SharePoint Online |
DataInsightAmazonS3 service, port 9393 | Amazon S3 |
HTTPS port 443 | Symantec Data Loss Prevention (DLP) |
HTTP port 80 or HTTPS/443 as configured by Enterprise Vault Server web service. | Enterprise Vault Server |
Portal Service, HTTPS port 443 Workflow Service, HTTPS port 8686 DataInsightConfig, service port 8282 Communication service, HTTPS port 8383 | Self-Service Portal server |
Communication service, HTTPS port 8383 Standard RPC ports 139 and 445 DataInsightConfig, service port 8282 DataInsightVICServer, service port 8989 | Classification Server |
8989 | DataInsightVICServer |
Note:
The default ports for Data Insight components are configurable at the time of installation.
Refer the table below for a different view about the port configuration. Both the tables carry similar information with separate views.
Table: List of default ports
Source | Destination Server | Destination Port | Description |
|---|---|---|---|
Web Browser | Management Server | 443 | Used for accessing Data Insight UI |
Web Browser | Portal UI | 443 | Used for accessing Data Insight UI |
Management Server | Collector | 8383 | Communication across Data Insight Nodes |
Management Server | Indexer | 8383 | Communication across Data Insight Nodes |
Management Server | Classification Server Role | 8383 | Communication across Data Insight Nodes |
Management Server | Windows Agent | 8383 | Communication across Data Insight Nodes |
Collector | Management Server | 8383 | Communication across Data Insight Nodes |
Collector | Indexer | 8383 | Communication across Data Insight Nodes |
Collector | Classification Server | 8383 | Communication across Data Insight Nodes |
Collector | Windows Agent | 8383 | Communication across Data Insight Nodes |
Indexer | Management Server | 8383 | Communication across Data Insight Nodes |
Indexer | Collector | 8383 | Communication across Data Insight Nodes |
Indexer | Indexer | 8383 | Communication across Data Insight Nodes |
Indexer | Classification | 8383 | Communication across Data Insight Nodes |
Classification | Indexer | 8383 | Communication across Data Insight Nodes |
Classifier | Management Server | 8383 | Communication across Data Insight Nodes |
Classifier | Collector | 8383 | Communication across Data Insight Nodes |
Classifier | Windows Agent | 8383 | Communication across Data Insight Nodes |
Windows Agent | Management Server | 8383 | Communication across Data Insight Nodes |
Windows Agent | Collector | 8383 | Communication across Data Insight Nodes |
Windows Agent | Classifier | 8383 | Communication across Data Insight Nodes |
Present on all Data Insight Nodes | Each Data Insight Nodes accesses its own port 8282 locally. There is no inter-server communication on this port. | 8282 | Configuration Service |
Data Insight Nodes Management Server and Portal Server | Data Insight Nodes Management Server and Portal Server | 8686 | Workflow Service |
Collector | Collector | 9090 | OneDrive Service (Runs locally) |
Collector | Collector | 9292 | SPOnline Service (Runs locally) |
Collector | Collector | 9393 | Amazon S3 Service (runs locally) |
Classifier | Classifier | 9393 | Amazon S3 Service (runs locally) |
Classifier | Classifier | 8989 | DataInsightVICServer Service (Runs locally) |
Collector | Collector | 8787 | NetApp Cluster-Mode service (Runs locally) |
Collector | Collector | 8585 | Generic Collector service (Runs locally) |
Management Server | Symantec Data Loss Prevention (DLP) | 443 | Used for Communication with Symantec DLP Server |
Management Server | Enterprise Vault Server | 80 | Used for Communication with EV Server |
Collector | NetApp Filers | HTTP port 80 and port 443, Standard RPC ports 139 and 445, 2049 (TCP, UDP) and 111 (TCP, UDP) for NFS | Data Insight communicates with NetApp Filers on specified ports |
Collector | NetApp Cluster Management Server | HTTP port 80 | Data Insight communicates with NetApp Cluster-Mode Filer on specified port |
Collector | EMC Celera/PowerScale | HTTP port 80 and HTTPS port 443 | Data Insight communicates with EMC Control Station on specified port |
Collector | Windows File Servers managed without an agent | Standard RPC ports 139 and 445 | Winnas share and storage discovery |
Collector | Veritas File System servers | HTTPS port 5634, and 2049 (TCP, UDP) and 111 (TCP, UDP) for NFS | Data Insight with Veritas File System Server on specified port |
Management Server | Active Directory Server | 389 or 636 (for TLS) | Data Insight communicates with AD Server on specified port |
Management Server | NIS Server | 111 (TCP, UDP), 714 (TCP), 711 (UDP) | Data Insight communicates with NIS Server on specified port |
Management Server | NIS+ Server in NIS compatibility mode | 111 (TCP, UDP), 714 (TCP), 711 (UDP) | Data Insight communicates with NIS+ Server on specified port |