Storage Foundation for Sybase ASE CE 7.4 Administrator's Guide - Linux
- Overview of Storage Foundation for Sybase ASE CE
- About Storage Foundation for Sybase ASE CE
- How SF Sybase CE works (high-level perspective)
- About SF Sybase CE components
- About optional features in SF Sybase CE
- How the agent makes Sybase highly available
- About Veritas InfoScale Operations Manager
- Administering SF Sybase CE and its components
- Administering SF Sybase CE
- Setting the environment variables for SF Sybase CE
- Starting or stopping SF Sybase CE on each node
- Applying operating system updates on SF Sybase CE nodes
- Adding storage to an SF Sybase CE cluster
- Recovering from storage failure
- Enhancing the performance of SF Sybase CE clusters
- Verifying the nodes in an SF Sybase CE cluster
- Administering VCS
- Viewing available Veritas device drivers
- Starting and stopping VCS
- Environment variables to start and stop VCS modules
- Adding and removing LLT links
- Configuring aggregated interfaces under LLT
- Displaying the cluster details and LLT version for LLT links
- Configuring destination-based load balancing for LLT
- Enabling and disabling intelligent resource monitoring for agents manually
- Administering the AMF kernel driver
- Administering I/O fencing
- About administering I/O fencing
- About the vxfentsthdw utility
- General guidelines for using the vxfentsthdw utility
- About the vxfentsthdw command options
- Testing the coordinator disk group using the -c option of vxfentsthdw
- Performing non-destructive testing on the disks using the -r option
- Testing the shared disks using the vxfentsthdw -m option
- Testing the shared disks listed in a file using the vxfentsthdw -f option
- Testing all the disks in a disk group using the vxfentsthdw -g option
- Testing a disk with existing keys
- About the vxfenadm utility
- About the vxfenclearpre utility
- About the vxfenswap utility
- Enabling or disabling the preferred fencing policy
- About I/O fencing log files
- Administering CVM
- Establishing CVM cluster membership manually
- Changing the CVM master manually
- Importing a shared disk group manually
- Deporting a shared disk group manually
- Verifying if CVM is running in an SF Sybase CE cluster
- Verifying CVM membership state
- Verifying the state of CVM shared disk groups
- Verifying the activation mode
- Administering CFS
- Administering the Sybase agent
- Sybase agent functions
- Monitoring options for the Sybase agent
- Using the IPC Cleanup feature for the Sybase agent
- Configuring the service group Sybase using the command line
- Bringing the Sybase service group online
- Taking the Sybase service group offline
- Modifying the Sybase service group configuration
- Viewing the agent log for Sybase
- Administering SF Sybase CE
- Troubleshooting SF Sybase CE
- About troubleshooting SF Sybase CE
- Restarting the installer after a failed network connection
- Installer cannot create UUID for the cluster
- Troubleshooting I/O fencing
- The vxfentsthdw utility fails when SCSI TEST UNIT READY command fails
- Node is unable to join cluster while another node is being ejected
- System panics to prevent potential data corruption
- Cluster ID on the I/O fencing key of coordinator disk does not match the local cluster's ID
- Fencing startup reports preexisting split-brain
- Registered keys are lost on the coordinator disks
- Replacing defective disks when the cluster is offline
- Troubleshooting Cluster Volume Manager in SF Sybase CE clusters
- Restoring communication between host and disks after cable disconnection
- Shared disk group cannot be imported in SF Sybase CE cluster
- Error importing shared disk groups in SF Sybase CE cluster
- Unable to start CVM in SF Sybase CE cluster
- CVM group is not online after adding a node to the SF Sybase CE cluster
- CVMVolDg not online even though CVMCluster is online in SF Sybase CE cluster
- Shared disks not visible in SF Sybase CE cluster
- Troubleshooting interconnects
- Troubleshooting Sybase ASE CE
- Prevention and recovery strategies
- Prevention and recovery strategies
- Verification of GAB ports in SF Sybase CE cluster
- Examining GAB seed membership
- Manual GAB membership seeding
- Evaluating VCS I/O fencing ports
- Verifying normal functioning of VCS I/O fencing
- Managing SCSI-3 PR keys in SF Sybase CE cluster
- Identifying a faulty coordinator LUN
- Starting shared volumes manually
- Listing all the CVM shared disks
- I/O Fencing kernel logs
- Prevention and recovery strategies
- Tunable parameters
- Appendix A. Error messages
CVM architecture
CVM is designed with a "master and slave" architecture. One node in the cluster acts as the configuration master for logical volume management, and all other nodes are slaves. Any node can take over as master if the existing master fails. The CVM master exists on a per-cluster basis and uses GAB and LLT to transport its configuration data.
Just as with VxVM, the Volume Manager configuration daemon, vxconfigd, maintains the configuration of logical volumes. This daemon handles changes to the volumes by updating the operating system at the kernel level. For example, if a mirror of a volume fails, the mirror detaches from the volume and vxconfigd determines the proper course of action, updates the new volume layout, and informs the kernel of a new volume layout. CVM extends this behavior across multiple nodes and propagates volume changes to the master vxconfigd.
Note:
You must perform operator-initiated changes on the master node.
The vxconfigd process on the master pushes these changes out to slave vxconfigd processes, each of which updates the local kernel. The kernel module for CVM is kmsg.
See Figure: Low-level communication.
CVM does not impose any write locking between nodes. Each node is free to update any area of the storage. All data integrity is the responsibility of the upper application. From an application perspective, standalone systems access logical volumes in the same way as CVM systems.
By default, CVM imposes a "Uniform Shared Storage" model. All nodes must connect to the same disk sets for a given disk group. Any node unable to detect the entire set of physical disks for a given disk group cannot import the group. If a node loses contact with a specific disk, CVM excludes the node from participating in the use of that disk.
Set the storage_connectivity tunable to asymmetric to enable a cluster node to join even if the node does not have access to all of the shared storage. Similarly, a node can import a shared disk group even if there is a local failure to the storage.
For detailed information, see the Storage Foundation Cluster File System High Availability Administrator's Guide.