Storage Foundation for Sybase ASE CE 7.4 Administrator's Guide - Linux
- Overview of Storage Foundation for Sybase ASE CE
- About Storage Foundation for Sybase ASE CE
- How SF Sybase CE works (high-level perspective)
- About SF Sybase CE components
- About optional features in SF Sybase CE
- How the agent makes Sybase highly available
- About Veritas InfoScale Operations Manager
- Administering SF Sybase CE and its components
- Administering SF Sybase CE
- Setting the environment variables for SF Sybase CE
- Starting or stopping SF Sybase CE on each node
- Applying operating system updates on SF Sybase CE nodes
- Adding storage to an SF Sybase CE cluster
- Recovering from storage failure
- Enhancing the performance of SF Sybase CE clusters
- Verifying the nodes in an SF Sybase CE cluster
- Administering VCS
- Viewing available Veritas device drivers
- Starting and stopping VCS
- Environment variables to start and stop VCS modules
- Adding and removing LLT links
- Configuring aggregated interfaces under LLT
- Displaying the cluster details and LLT version for LLT links
- Configuring destination-based load balancing for LLT
- Enabling and disabling intelligent resource monitoring for agents manually
- Administering the AMF kernel driver
- Administering I/O fencing
- About administering I/O fencing
- About the vxfentsthdw utility
- General guidelines for using the vxfentsthdw utility
- About the vxfentsthdw command options
- Testing the coordinator disk group using the -c option of vxfentsthdw
- Performing non-destructive testing on the disks using the -r option
- Testing the shared disks using the vxfentsthdw -m option
- Testing the shared disks listed in a file using the vxfentsthdw -f option
- Testing all the disks in a disk group using the vxfentsthdw -g option
- Testing a disk with existing keys
- About the vxfenadm utility
- About the vxfenclearpre utility
- About the vxfenswap utility
- Enabling or disabling the preferred fencing policy
- About I/O fencing log files
- Administering CVM
- Establishing CVM cluster membership manually
- Changing the CVM master manually
- Importing a shared disk group manually
- Deporting a shared disk group manually
- Verifying if CVM is running in an SF Sybase CE cluster
- Verifying CVM membership state
- Verifying the state of CVM shared disk groups
- Verifying the activation mode
- Administering CFS
- Administering the Sybase agent
- Sybase agent functions
- Monitoring options for the Sybase agent
- Using the IPC Cleanup feature for the Sybase agent
- Configuring the service group Sybase using the command line
- Bringing the Sybase service group online
- Taking the Sybase service group offline
- Modifying the Sybase service group configuration
- Viewing the agent log for Sybase
- Administering SF Sybase CE
- Troubleshooting SF Sybase CE
- About troubleshooting SF Sybase CE
- Restarting the installer after a failed network connection
- Installer cannot create UUID for the cluster
- Troubleshooting I/O fencing
- The vxfentsthdw utility fails when SCSI TEST UNIT READY command fails
- Node is unable to join cluster while another node is being ejected
- System panics to prevent potential data corruption
- Cluster ID on the I/O fencing key of coordinator disk does not match the local cluster's ID
- Fencing startup reports preexisting split-brain
- Registered keys are lost on the coordinator disks
- Replacing defective disks when the cluster is offline
- Troubleshooting Cluster Volume Manager in SF Sybase CE clusters
- Restoring communication between host and disks after cable disconnection
- Shared disk group cannot be imported in SF Sybase CE cluster
- Error importing shared disk groups in SF Sybase CE cluster
- Unable to start CVM in SF Sybase CE cluster
- CVM group is not online after adding a node to the SF Sybase CE cluster
- CVMVolDg not online even though CVMCluster is online in SF Sybase CE cluster
- Shared disks not visible in SF Sybase CE cluster
- Troubleshooting interconnects
- Troubleshooting Sybase ASE CE
- Prevention and recovery strategies
- Prevention and recovery strategies
- Verification of GAB ports in SF Sybase CE cluster
- Examining GAB seed membership
- Manual GAB membership seeding
- Evaluating VCS I/O fencing ports
- Verifying normal functioning of VCS I/O fencing
- Managing SCSI-3 PR keys in SF Sybase CE cluster
- Identifying a faulty coordinator LUN
- Starting shared volumes manually
- Listing all the CVM shared disks
- I/O Fencing kernel logs
- Prevention and recovery strategies
- Tunable parameters
- Appendix A. Error messages
About I/O fencing in SF Sybase CE environment
I/O fencing is a mechanism to prevent uncoordinated access to the shared storage. This feature works even in the case of faulty cluster communications causing a split-brain condition. Veritas provides a technology called I/O fencing to remove the risk associated with split-brain. I/O fencing allows write access for members of the active cluster and blocks access to storage from non-members; even a node that is alive is unable to cause damage.
SCSI-3 Persistent Reservations (SCSI-3 PR) are required for I/O fencing and resolve the issues of using SCSI reservations in a clustered SAN environment. SCSI-3 PR enables access for multiple nodes to a device and simultaneously blocks access for other nodes.
Fencing involves coordinator disks and data disks. Each component has a unique purpose and uses different physical disk devices. The fencing driver, known as vxfen, directs CVM as necessary to carry out actual fencing operations at the disk group level. Fencing uses GAB port b for its communication.
In addition to providing I/O fencing capabilities, the I/O fencing module VxFEN is also used to notify Sybase ASE of membership changes on the VCS cluster. When a node is booting, VxFEN will come up after LLT and GAB, process membership information, and reach regular running state. When VxFEN later launches vxfend, the I/O fencing daemon that is used for communication, this daemon first opens a UNIX socket and registers with VCMP, a thread of Sybase ASE. The vxfend daemon is responsible for the communication between VxFEN and VCMP. If the handshake between vxfend and VCMP is successful, vxfend calls an ioctl into the VxFEN kernel module and awaits instructions. VxFEN proceeds to send the current cluster view from VCS perspective to Sybase ASE. When a connection between VxFEN and Sybase ASE has already been established, cluster membership change notification messages are delivered as soon as VxFEN completes any necessary actions (for example, after fencing out departing nodes or lost nodes).