Storage Foundation for Sybase ASE CE 7.4 Administrator's Guide - Linux
- Overview of Storage Foundation for Sybase ASE CE
- About Storage Foundation for Sybase ASE CE
- How SF Sybase CE works (high-level perspective)
- About SF Sybase CE components
- About optional features in SF Sybase CE
- How the agent makes Sybase highly available
- About Veritas InfoScale Operations Manager
- Administering SF Sybase CE and its components
- Administering SF Sybase CE
- Setting the environment variables for SF Sybase CE
- Starting or stopping SF Sybase CE on each node
- Applying operating system updates on SF Sybase CE nodes
- Adding storage to an SF Sybase CE cluster
- Recovering from storage failure
- Enhancing the performance of SF Sybase CE clusters
- Verifying the nodes in an SF Sybase CE cluster
- Administering VCS
- Viewing available Veritas device drivers
- Starting and stopping VCS
- Environment variables to start and stop VCS modules
- Adding and removing LLT links
- Configuring aggregated interfaces under LLT
- Displaying the cluster details and LLT version for LLT links
- Configuring destination-based load balancing for LLT
- Enabling and disabling intelligent resource monitoring for agents manually
- Administering the AMF kernel driver
- Administering I/O fencing
- About administering I/O fencing
- About the vxfentsthdw utility
- General guidelines for using the vxfentsthdw utility
- About the vxfentsthdw command options
- Testing the coordinator disk group using the -c option of vxfentsthdw
- Performing non-destructive testing on the disks using the -r option
- Testing the shared disks using the vxfentsthdw -m option
- Testing the shared disks listed in a file using the vxfentsthdw -f option
- Testing all the disks in a disk group using the vxfentsthdw -g option
- Testing a disk with existing keys
- About the vxfenadm utility
- About the vxfenclearpre utility
- About the vxfenswap utility
- Enabling or disabling the preferred fencing policy
- About I/O fencing log files
- Administering CVM
- Establishing CVM cluster membership manually
- Changing the CVM master manually
- Importing a shared disk group manually
- Deporting a shared disk group manually
- Verifying if CVM is running in an SF Sybase CE cluster
- Verifying CVM membership state
- Verifying the state of CVM shared disk groups
- Verifying the activation mode
- Administering CFS
- Administering the Sybase agent
- Sybase agent functions
- Monitoring options for the Sybase agent
- Using the IPC Cleanup feature for the Sybase agent
- Configuring the service group Sybase using the command line
- Bringing the Sybase service group online
- Taking the Sybase service group offline
- Modifying the Sybase service group configuration
- Viewing the agent log for Sybase
- Administering SF Sybase CE
- Troubleshooting SF Sybase CE
- About troubleshooting SF Sybase CE
- Restarting the installer after a failed network connection
- Installer cannot create UUID for the cluster
- Troubleshooting I/O fencing
- The vxfentsthdw utility fails when SCSI TEST UNIT READY command fails
- Node is unable to join cluster while another node is being ejected
- System panics to prevent potential data corruption
- Cluster ID on the I/O fencing key of coordinator disk does not match the local cluster's ID
- Fencing startup reports preexisting split-brain
- Registered keys are lost on the coordinator disks
- Replacing defective disks when the cluster is offline
- Troubleshooting Cluster Volume Manager in SF Sybase CE clusters
- Restoring communication between host and disks after cable disconnection
- Shared disk group cannot be imported in SF Sybase CE cluster
- Error importing shared disk groups in SF Sybase CE cluster
- Unable to start CVM in SF Sybase CE cluster
- CVM group is not online after adding a node to the SF Sybase CE cluster
- CVMVolDg not online even though CVMCluster is online in SF Sybase CE cluster
- Shared disks not visible in SF Sybase CE cluster
- Troubleshooting interconnects
- Troubleshooting Sybase ASE CE
- Prevention and recovery strategies
- Prevention and recovery strategies
- Verification of GAB ports in SF Sybase CE cluster
- Examining GAB seed membership
- Manual GAB membership seeding
- Evaluating VCS I/O fencing ports
- Verifying normal functioning of VCS I/O fencing
- Managing SCSI-3 PR keys in SF Sybase CE cluster
- Identifying a faulty coordinator LUN
- Starting shared volumes manually
- Listing all the CVM shared disks
- I/O Fencing kernel logs
- Prevention and recovery strategies
- Tunable parameters
- Appendix A. Error messages
About coordination points
Coordination points provide a lock mechanism to determine which nodes get to fence off data drives from other nodes. A node must eject a peer from the coordination points before it can fence the peer from the data drives. Racing for control of the coordination points to fence data disks is the key to understand how fencing prevents split-brain.
Disks that act as coordination points are called coordinator disks. Coordinator disks are three standard disks or LUNs set aside for I/O fencing during cluster reconfiguration. Coordinator disks do not serve any other storage purpose in the SF Sybase CE configuration.
You can configure coordinator disks to use Veritas Volume Manager Dynamic Multi-pathing (DMP) feature. Dynamic Multi-pathing (DMP) allows coordinator disks to take advantage of the path failover and the dynamic adding and removal capabilities of DMP. So, you can configure I/O fencing to use either DMP devices or the underlying raw character devices. I/O fencing uses SCSI-3 disk policy that is either raw or dmp based on the disk device that you use. The disk policy is raw by default. Veritas recommends using the DMP disk policy.
See the Storage Foundation Administrator's Guide.