Problem
When the I/O module from the storage shelf fails or is removed, an alert is sent for each drive that shows the status as Degraded. After the I/O module issue is fixed, the same number of resolution emails are sent.
Error Message
The email alert includes content similar to the following:
The disk drive is either not always responding or not fully operational
Time of event: 2025-05-12 15:21:50 (+00:00)
UMI event code: V-475-500-0201
Component type: Disk
Component: ExpansionShelf 2 Drawer 0 Slot 12
Status: Degraded
State: WARNING
Additional information about this error is available at the following link:
V-475-500-0201
Cause
When the I/O module fails or is removed, the data path to the drive is no longer redundant. Therefore, all of the drives go into a Degraded state, which is expected behavior.
As per the current design of the storage monitoring plug-in, separate alerts are sent for each of the drives, which results in a large number of alerts.
Solution
In this scenario, the alerts can be ignored.
At this time, there are no plans to address this issue through a patch or hotfix in the current or previous versions of the software. Although this issue may potentially be resolved in a future major revision, it is not currently scheduled for any upcoming release. If this issue has a significant business impact on your continued use of the product, please contact your Sales representative or the Sales team to discuss your concerns.