StorageGRID (S3) response may be empty when EV tries to verify the object immediately after writing it into the partition
Error Message
Event ID: 29139
Task Category: Storage Archive
Level: Error
Description:
Unable to perform the operation for 'NetApp StorageGRID (S3) Streamer'
CCloudStreamerObject::Write method failed for partition entry id 1C23F7D94456B1B4A94974E00465F3C01q10000evlab
Reason = 0x8000ffff
Description = Catastrophic failure
Event ID: 29139
Task Category: Storage Archive
Level: Error
Description:
Unable to perform the operation for 'NetApp StorageGRID (S3) Streamer'
CCloudStreamerObject::Write method failed for partition entry id 1C82F7D94253B1B4A946056E00465F3C01q10000evlon
Reason = 0x80004005
Description = HTTP response code: -1
Cause
There are multiple issues causing this error:
- The Version ID of the object being written to the bucket could not be obtained using the default method to fetch it.
- The default timeout values are too low for large sized files.
Solution
This issue has been fixed in Enterprise Vault 14.4.2 and later versions.
NOTE: Additional setting configurations will need to be performed if partition device type is different then Netapp StorageGrid. Please contact Veritas Support for the additional steps needed if device type IS NOT Netapp StorageGrid S3.
For more information about populating the Enterprise Vault Admin Console settings, see https://www.veritas.com/support/en_US/article.100039174.