Problem:
The Appliance is reporting a problem with the power supplies.
Error Message:
Various logs from the DataCollect recorded errors.
Alarm-Log_10-09-2018_12.50.03.log:
ca | 10/07/2018 | 10:00:08 | Power Supply #0x51 | Presence detected | Deasserted
cb | 10/07/2018 | 10:00:09 | Power Supply #0x50 | Presence detected | Deasserted
SDR-ELIST-Log_10-09-2018_12.50.03.log
PS1 Input Power | 54h | ns | 10.1 | No Reading
PS2 Input Power | 55h | ns | 10.2 | No Reading
PS1 Curr Out % | 58h | ns | 10.1 | No Reading
PS2 Curr Out % | 59h | ns | 10.2 | No Reading
PS1 Temperature | 5Ch | ns | 10.1 | No Reading
PS2 Temperature | 5Dh | ns | 10.2 | No Reading
P1 Status | 70h | ok | 3.1 | Presence detected
P2 Status | 71h | ok | 3.2 | Presence detected
FRU-Log_10-09-2018_12.50.03.log
FRU Device Description : Pwr Supply 1 FRU (ID 2)
Device not present (Unknown (0x81))
FRU Device Description : Pwr Supply 2 FRU (ID 3)
Device not present (Unknown (0x81))
Cause:
BMC sensor loses connection and needs to be reset.
Solution:
- Stop all NetBackup activity and power down the appliance.
- Pull the power cables from both chassis power supplies (PSU).
- Wait two (2) minutes.
- Physically re-seat each PSU and attach the power cable.
- Power up the appliance.
- Wait an hour and review TestHardware-log.