Description
This document attempts to explain how to list the EMC SRDF "RDF" defined groups for an EMC Symmetrix (DMX) array.
Prior to creating a new EMC SRDF "RDF" group, a RDF group number (GrpNum) and corresponding RDF director port details is required for both the local and remote EMC enclosures.
Sample configuration
Figure 1.0
The EMC SYMCLI command "symcfg -sid <sid> list -rdfg all" can be used to list the defined SRDF "RDF" groups for a given EMC Symmetrix (DMX) array.
Sample output
Local EMC Symmetrix ID (SID) "822":
Dopey # symcfg -sid 822 list -rdfg all
Symmetrix ID : 000290300822
S Y M M E T R I X R D F G R O U P S
Local Remote Group RDFA Info
-------------- --------------------- ----------------------- -----------------
LL Flags Dir Flags Cycle
RA-Grp (sec) RA-Grp SymmID T Name LPDS Cfg CSRM time Pri
-------------- --------------------- ----------------------- ----- ----- ---
1 ( 0) 10 1 ( 0) 000290301414 S SETUP_GRP .X.. F-S -IS- 30 33
2 ( 1) 10 2 ( 1) 000290301414 D Sol-01 .XX. F-S -IS- 30 33
3 ( 2) 10 3 ( 2) 000290301414 D Sol-02 .XX. F-S -IS- 30 33
4 ( 3) 10 4 ( 3) 000290301414 D Sol-03 XX.. F-S -IS- 30 33
5 ( 4) 10 5 ( 4) 000290301414 D Sol-04 XX.. F-S -IS- 30 33
6 ( 5) 10 6 ( 5) 000290301414 D Sol-05 XX.. F-S -IS- 30 33
7 ( 6) 10 7 ( 6) 000290301414 D aix-01 XX.. F-S -IS- 30 33
8 ( 7) 10 8 ( 7) 000290301414 D ESX-01 XX.. F-S -IS- 30 33
9 ( 8) 10 9 ( 8) 000290301414 D v20z-03-04 XX.. F-S -IS- 30 33
10 ( 9) 10 10 ( 9) 000290301414 D 710_03-06 XX.. F-S -IS- 30 33
Legend:
? : Unknown
Group (T)ype : S = Static, D = Dynamic
Director (C)onfig : F-S = Fibre-Switched, F-H = Fibre-Hub
G = GIGE, E = ESCON, T = T3, - = N/A
Group Flags :
Prevent Auto (L)ink Recovery : X = Enabled, . = Disabled
Prevent RAs Online Upon (P)ower On: X = Enabled, . = Disabled
Link (D)omino : X = Enabled, . = Disabled
(S)TAR mode : N = Normal, R = Recovery, . = OFF
RDFA Flags :
(C)onsistency : X = Enabled, . = Disabled, - = N/A
(S)tatus : A = Active, I = Inactive, - = N/A
(R)DFA Mode : S = Single-session, M = MSC, - = N/A
(M)sc Cleanup : C = MSC Cleanup required, - = N/A
Note: In this instance, "11" is the next available "GrpNum" number.
Repeat the command for the "remote" EMC enclosure using the "symcfg -sid <sid> list -rdfg all" command.
Remote EMC Symmetrix ID (SID) "414":
Bashful # symcfg -sid 414 list -rdfg all
Symmetrix ID : 000290301414
S Y M M E T R I X R D F G R O U P S
Local Remote Group RDFA Info
-------------- --------------------- ----------------------- -----------------
LL Flags Dir Flags Cycle
RA-Grp (sec) RA-Grp SymmID T Name LPDS Cfg CSRM time Pri
-------------- --------------------- ----------------------- ----- ----- ---
1 ( 0) 10 1 ( 0) 000290300822 S SETUP_GRP .X.. F-S -IS- 30 33
2 ( 1) 10 2 ( 1) 000290300822 D Sol-01 .XX. F-S -IS- 30 33
3 ( 2) 10 3 ( 2) 000290300822 D Sol-02 .XX. F-S -IS- 30 33
4 ( 3) 10 4 ( 3) 000290300822 D Sol-03 XX.. F-S -IS- 30 33
5 ( 4) 10 5 ( 4) 000290300822 D Sol-04 XX.. F-S -IS- 30 33
6 ( 5) 10 6 ( 5) 000290300822 D Sol-05 XX.. F-S -IS- 30 33
7 ( 6) 10 7 ( 6) 000290300822 D aix-01 XX.. F-S -IS- 30 33
8 ( 7) 10 8 ( 7) 000290300822 D ESX-01 XX.. F-S -IS- 30 33
9 ( 8) 10 9 ( 8) 000290300822 D v20z-03-04 XX.. F-S -IS- 30 33
10 ( 9) 10 10 ( 9) 000290300822 D 710_03-06 XX.. F-S -IS- 30 33
Legend:
? : Unknown
Group (T)ype : S = Static, D = Dynamic
Director (C)onfig : F-S = Fibre-Switched, F-H = Fibre-Hub
G = GIGE, E = ESCON, T = T3, - = N/A
Group Flags :
Prevent Auto (L)ink Recovery : X = Enabled, . = Disabled
Prevent RAs Online Upon (P)ower On: X = Enabled, . = Disabled
Link (D)omino : X = Enabled, . = Disabled
(S)TAR mode : N = Normal, R = Recovery, . = OFF
RDFA Flags :
(C)onsistency : X = Enabled, . = Disabled, - = N/A
(S)tatus : A = Active, I = Inactive, - = N/A
(R)DFA Mode : S = Single-session, M = MSC, - = N/A
(M)sc Cleanup : C = MSC Cleanup required, - = N/A
Note: In this instance, "11" is the next available "GrpNum" number.