For generic device type of filer, the storage license calculates Size from the same underlying Physical namespace when a parent and its sub-folders are shared in Data Insight
Article: 100033689
Last Published: 2023-09-19
Ratings: 0 0
Product(s): Data Insight
Problem
Data Insight computes the same size twice, for the calculation of total monitored storage, on the licensing page, in scenarios where a share’s underlying physical path, and its sub-folders paths, are added, under monitored shares, by Data Insight administrators.The licensing page displays that the license is exceeded, and the status bar of the console will have a warning message.
Error Message

Cause
This behavior is observed for generic devices. Currently, Data Insight is not able to distinguish between the physical and the logical paths that are coming from multiple shares. As a result, during the computation of the total storage capacity, Data Insight considers the nested storage as independent storage.Detailed information about licensing is documented within the Overview of Data Insight licensing section of the Veritas Data Insight Administrators Guide:
Veritas Data Insight Administrator's Guide
Solution
While adding shares from type "generic device," ensure that only the parent physical path (the top-most shared folder) is being monitored by Data Insight.