vxconfigd can not up : VxVM vxconfigd ERROR V-5-1-0 Segmentation violation

Article: 100008603
Last Published: 2012-09-09
Ratings: 1 0
Product(s): InfoScale & Storage Foundation

Problem

vxconfigd can not up  :  VxVM vxconfigd ERROR V-5-1-0 Segmentation violation

Error Message

# vxconfigd -m enable
06/25 16:11:42:  VxVM vxconfigd ERROR V-5-1-0 Segmentation violation
#

in OS  messages:

Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd: V-5-1-16346 ddl_vendor_claim_device: EMC_CLARiiON array wth cabsno = FCN00122000035 reports LUNS of both ALUA and CLR-A/PF array types
Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd: : Success
Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd: V-5-1-16346 ddl_vendor_claim_device: EMC_CLARiiON array wth cabsno = FCN00122000035 reports LUNS of both ALUA and CLR-A/PF array types
Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd: : Success
Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd: V-5-1-16346 ddl_vendor_claim_device: EMC_CLARiiON array wth cabsno = FCN00122000035 reports LUNS of both ALUA and CLR-A/PF array types
Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd: : Success
Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd: V-5-1-16346 ddl_vendor_claim_device: EMC_CLARiiON array wth cabsno = FCN00122000035 reports LUNS of both ALUA and CLR-A/PF array types
Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd: : Success
Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd: V-5-1-16346 ddl_vendor_claim_device: EMC_CLARiiON array wth cabsno = FCN00122000035 reports LUNS of both ALUA and CLR-A/PF array types
Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd: : Success
Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd: V-5-1-16346 ddl_vendor_claim_device: EMC_CLARiiON array wth cabsno = FCN00122000035 reports LUNS of both ALUA and CLR-A/PF array types
Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd: : Success
Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd: V-5-1-12104 vxvm:vxconfigd: WARNING: File /etc/vx/array.info does not exist.
Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd: This file will be generated when switching to ENABLED mode.
Jun 25 16:11:42 smdf-db1 vxvm:vxconfigd:
Jun 25 16:11:42 smdf-db1 kernel: [ 6270.163565] vxconfigd[19629]: segfault at 4 ip 00000000081d846a sp 00000000ff9cb100 error 4 in vxconfigd[8048000+2ae000]
 

Cause

in the EMC VNC 5100 array, all Luns which map to the node : failover mode is different . (some are set to 1 ,and others set to 4 )

Solution

correspond all Luns failover mode to 4 , then issue resolved


Applies To

EMC VNC 5100 storage

SuSE11 SP1

VxVM 6.0RP1

# cat /etc/SuSE-release
SUSE Linux Enterprise Server 11 (x86_64)
VERSION = 11
PATCHLEVEL = 1
#
# rpm -aq|grep -i vxvm
VRTSvxvm-6.0.001.000-RP1_SLES11

Was this content helpful?