Problem
EMM interface initialization failed, status = 334
Error Message
Found below event occurred on Master server
1. EMM interface initialization failed, status = 334
2. Event Source: Application Error, Event ID: 1000, Faulting application nbemm.exe, version, faulting module msvcr71.dll, version 7.10.3052.4, fault address 0x000017fb
.
Cause
"vxdbms.conf" file was empty and 0 kb file which seems that corrupted after Disk space full.
Solution
1. Event logs in the application error and event id 1000.
2. Very Low disk space on drive where Netbackup installed.
3. Need to create significant disk space on that drive.
4. Rename vxdbms.conf file to vxdbms.conf_OLD file.
5. Run this command "create_nbdb -config_only –force" from netbackup\bin folder to recreate the vxdbms.conf file which was successfully completed.
Applies To
NBU 6.5.6 and windows 2003 server sp2