Unable to configure or enable worm on a VDD pool on Access Appliance. Invalid values specified for retention period

Error Message


clish> dedupe enable-worm 86400s 999999999s
Access Appliance dedupe ERROR V-493-10-6223 Failed to set retention values. Invalid values specified for retention period.
 

Cause

The retention values used are outside the permissable range.

Solution

The minimum retention value allowed is 3600s  (1 hour)

The maximum retention value allowed is 946080000s (30 years)