Problem

IBM SVC Data Collection is not completing in NetBackup IT Analytics.
 

Error Message

Logs show CIMOM service timed out error:

<Timestamp> ERROR  5536 main:IBMSVCChildThread:<server> SVCReader.<init>:103 - Connection to SVC CIMOM service using https://<server>/root/ibm failed due to XMLERROR:
enumerateInstances,java.net.ConnectException: Connection timed out: connect - <server>:5989
<Timestamp> ERROR  5536 main:IBMSVCChildThread:<server> IBMSVCChildThread.process:130 - Caught a CIMException while saving StorageArray Details.XMLERROR:
enumerateInstances,java.net.ConnectException: Connection timed out: connect - <server>:5989
<Timestamp> INFO   5536 main:IBMSVCChildThread:<server> IBMSVCChildThread.logGenericMessage:275 - Logging APT-ISVC-1000003 with details XMLERROR:
enumerateInstances,java.net.ConnectException: Connection timed out: connect - <server>:5989 

 

Cause

The CIMOM service on IBM SVC can become hung and will not process requests from NetBackup IT Analytics.
 

Solution

Restart CIMOM service using IBM SVC User Interface (UI).
 